Notes:
Before you begin, ensure that:
ReXgen air device is fully powered, and the USB is connected to the laptop.
ReXdesk is not open when using this tool.
Create a configuration with AWS Upload and send it to the logger.
Close ReXdesk and open the Debug tool.
Click on “Connect Rexgen”.
The output should show “CONNECTED: 4”
Now click on Debug LTE Open; this will start the debugging process.
If the connection is successful, the output window will show
“### Status Send Start### Status Send OK”
Editable Example:
Or
*Some content in the output window will differ for different SIM providers and Amazon regions.
If the output doesn’t show Status Send OK, please copy the log, paste it into a text file and share it with Influx Technology support.
One Test is completed. Restart the logger entirely by removing the USB and full power to bring it to a normal state.