The configuration panel comprises the available bus options, toolbar, SD card options, and live monitoring options.
CAN
CAN Icons
Description
Log All
The log All function will enable logging all the CAN/CAN FD messages on the CAN/CAN FD bus.
CAN Errors
CAN Errors function enables logging of CAN bus errors in the data file. See Appendix 1 for various error codes
Filter
The filter function enables you to configure CAN/CAN FD logging by defining CAN/CAN FD ID pass filters.
J1939 Filter
Allows the user to configure J1939 filtering for the source address, destination address, and PGN filtering.
Periodic
Allows the user to configure Periodic Transmission of CAN/CAN FD messages from ReXgen.
HW Info
Allows the user to configure the transmission of Hardware Diagnostics information
LIN
LIN Tool Bar Icons
Description
Log All
The log All function will enable logging all the LIN messages on the LINbus.
Schedule
Allows the user to use the ReXgen device in master mode by loading the schedule table from the LDF file.
CHANNELS
Channels Icons
Description
Analog
Allows the user to add an analogue channel and set the sampling rate and conversion formula.
Dig in
Allows the user to add digital channels and set the sampling rate.
IMU & GNSS
Allows the user to configure IMU channels and GNSS channels.
Transmitting Options
Transmitting Options Icons
Description
Periodic
Allows the user to configure Periodic Transmission of CAN/CAN FD messages from ReXgen.
HW Info
Allows the user to configure the transmission of Hardware Diagnostics information.
Snapshot
Allows the user to transmit a periodic sample of decoded CAN bus data for select CAN messages of interest in the Jason format.
Clicking on the LIN icon will open the LIN bus settings.
Protocol Version– This allows the user to choose the protocol version.
Baudrate (bit/s)– This allows the user to define the baud rate for the LIN bus.
Time Base (ms)– This allows the user to schedule LIN frame slots based on a LIN cluster time unit called the LIN time base, usually 5 or 10 mS.
Time Jitter (ms)– This allows the user to delay the tolerance specified for the Master node, which will be available in the LDF file.
Master Mode– This allows the user to activate the master mode, which becomes active when the user loads a schedule table.
How to configure ReXgen data logger to data.
Clicking on CAN 0 or CAN 1 icons will open the bus settings.
Type– Allows the user to choose between CAN or CAN FD bus.
Autodetect bus speed– Enables auto-detection of CAN bus speed.
CAN Speed– This allows the user to select CAN bus speed. 125Kbps – 1000 Kbps.
Silent Mode– Enables the silent mode.
Type– Allows the user to choose between CAN or CAN FD bus.
Autodetect bus speed– Enables auto-detection of CAN bus speed.
CAN Speed (Arbitration Phase)– This allows the user to select CAN bus speed. 125 – 1000 Kbps.
CAN FD Speed (Data Phase)– This allows the user to select CAN FD speed 1 Mbit – 8 Mbit.
Silent Mode– Enables the silent mode.
CAN FD Non-ISO– This allows the user to enable Non-ISO CAN FD mode
Analog channel– This allows the user to configure the analogue channel.
The user can set the analogue channel, sampling rate, and formula.
Digital channel– This allows the user to configure the digital channel.
The user can set the digital channel and sampling rate.
The user can set the range and sampling rate.
Refer to Appendix 3 – GNSS Orientation Guide
Sampling Rate (Hz) – allows the user to set the desired sampling rate ranging from 1 to 30Hz.
Platform – Allows users to select the ‘environment‘ from the listed options.
GNSS Type – Specifies the types of different GNSS(s) supported. Select ‘Enable’ to specify the preferred GNSS(s) from the listed options.
Geofence – allows the user to set geofencing parameters.
Refer to Appendix 3 – GNSS Orientation Guide
Radius: define the radius to adjust the location's proximity in meters.
Latitude: specify to mark the latitudinal location.
Longitude: specify to mark the longitudinal location.
The module draws a circle using the values specified for the Longitude, Latitude and radius.
Select Items to log – allows the users to specify the items listed under specific categories.
Standard—Enable the ‘Standard’ option to log all the standard parameters, such as longitude, latitude, altitude, speed over ground, and course over ground.
Extended—Enable the ‘Extended’ option to log parameters such as quality, number of satellites, geoid separation, and ground distance.
Altitude orientation—Enable the ‘Attitude’ option to log parameters responsible for altitude orientation, such as the vehicle’s pitch, roll and heading (yaw).
IMU—Enable the ‘IMU’ option to log parameters responsible for IMU orientation (m/sec2), such as acceleration axes x-y-z and angular rate axes x-y-z.
Refer to Appendix 3 – GNSS Orientation Guide
Geofence—Enable the ‘Geofencing’ option to log up to one circular geofencing area.
Accuracy —Enable the ‘Accuracy’ to log all the parameters responsible for accuracy.
Click “Storage” in the Device Configuration
Max Logging Time– This allows the user to specify the maximum log duration for a data log.
Max Log Size– This allows the user to specify the maximum log size for a data log.
How to configure reXgen data logger to data.
How to in ReXgen Data Logger using DBC file.
How to configure rexgen data logger to log data using .
How to using ReXdesk.
How to using ReXdesk.
Value
Output
0
Unknown (insufficient satellites for detection)
1
Inside the Geofencing Parameter
2
Outside the Geofencing Parameter
Allows the user to add a filter.
Allows the user to edit the added filter.
Allows the user to remove the added filter.
Source Address
Allows the user to filter out J1939 frame IDs based on source address.
Destination Address
Allows users to filter out J1939 frame IDs based on the destination address.
PGN values
Allows the user to filter out J1939 frame IDs based on PGN.
Allows the user to browse PGN from added DBC.
After following the steps from the section Tool Menu (Encryption Manager)
Click “Encrypt” in the device configuration.
Select the generated key.
Select the required encryption option.
Enabling the “Encrypt data” log will generate encrypted log data for the updated configuration.
Enabling “Lock Device “will lock the ReXgen device.
For decrypting- From the Encryption manager, select the key used for encryption and click on “Use selected Key.”
Click “Run” to update the configuration.
After following the steps from section 2.2.3 Tool Menu (Cloud Settings>> FTP settings):
Click upload in "Device configuration."
Select the added Mobile settings and FTP settings.
Store data to FTP using mobile internet: Enable data storage (to FTP) using mobile internet.
Mobile: Enter the name defined in the SIM settings.
FTP: Enter the name defined in the server settings.
Check Config Time (min): Checks for new config on the server (at a given delay).
Send status Time (min): Updated the status in the given time (at a given delay).
Check Firmware Update: Checks for new firmware on the server (at a given delay).*
Automatic Firmware Update: This enables updating the firmware automatically.*
*Will be enabled with the upcoming versions.
Click "Run" to update the configuration.
*Always format the logger's internal storage after sending a configuration with AWS or FTP enabled.
How to in ReXgen (tutorial video).
How to in ReXdesk
The logger goes to sleep mode when both the CAN bus become inactive.
Following are the triggers that can wake the logger when it is in Deep/Normal Sleep Mode:
*Will be enabled in the next quarter.
Deep Sleep: 1mA.
Normal Sleep: 25 mA
The sleep delay is specified in the “Sleep after no CAN activity for (minutes).”
Three types of sleep modes are available:
No sleep
Deep Sleep
Normal Sleep
ReXgen will not use the Sleep/Wakeup function when ‘No Sleep’ is selected.
Deep sleep mode with a power consumption of 1 mA
Enable ‘Wake Up On Movement’ to wake up the logger on movement.
Normal sleep mode with a power consumption of 25 mA.
Wake Up On CAN 0: The logger will wake up from sleep mode when CAN activity is on the CAN 0 Bus.
Wake Up On CAN 1: The logger will wake up from sleep mode when CAN activity is on the CAN 1 Bus.
Wake Up Once: The logger will wake up from sleep mode once on the specified date at the specified time.
Wake Up Everyday: The logger will wake up from sleep mode at a specified time every day.
Wake Up Minutes after Sleep: The logger will wake up from sleep mode after the specified time in minutes.
The logger will wake up from sleep mode once any movement is detected.
Note:
Available only in ReXgen Air Devices.
How to in a ReXgen data logger.
Wake UP Options
Deep Sleep(1mA)
Normal Sleep (25mA)
USB
Yes
CAN0
Yes
Yes
CAN1
Yes
Yes
ALARM
Yes
ACCELEROMETER*
Yes
CLAMP/ERASE PIN*
Yes
*FTPS- PROT P (Data channel encryption not supported.)
Click on the AWS icon in device Configuration: - (Amazon Web Services S3 ("Simple Storage Service"))
Click on Enable AWS and fill in the required details.
Mobile: This allows the user to select the required Mobile APN from the List.
S3: This allows the user to select and specify the bucket name stored in Cloud settings.
Firmware Check Time (sec): Checks for new firmware on the server (at a specified interval).
Status Send Time (sec): Sends the status to the server (at a specified interval).
Configuration Check Time (sec): Checks for new configurations on the server (at a specified interval).
Automatic Firmware Update: Enable updating the firmware automatically.*
*Will be enabled with the upcoming versions.
Encrypt Password: Enable encrypting the password.
Keep Log Files On Device: Enable to keep the log files on the device. If enabled, format the eMMC after sending the configuration.
Upload All Files Before Sleep: This enables the user to direct the logger to upload all the files to the S3 server before the logger enters sleep mode.
*Always format the logger's internal storage after sending a configuration with AWS or FTP enabled.
How to in ReXdesk.
Online– Enables live monitoring of CAN traces.
Clear– Clears current traces displayed in the window.
Export– Enables the user to export the traces in .asc format.