CT is more rugged with IP 65 rating and can support up to 7 CANbus and Flexray. One of the most powerful logger that supports advanced protocols like xCP/CCP.
It is available under the influx technology folder in the Start menu. If it is not availble there, then please install from the Influx technology support page. https://www.influxtechnology.com/support
Ensure the Rebel Driver is installed on your computer.
Open the Licence Manager from the Dialog Help section, Note down the Activation identification code, and De Activate the Licence from the existing PC. In the new PC, use the I Moved from Another PC option.
There could be several reasons:
Ensure that you have configured the correct Baud Rate.
Make sure the physical connections are correct.
Ensure CAN Bus is terminated.
For more info, refer to our website's Troubleshooting flow chart in Dialog Help or the CAN Troubleshooting guide.
There could be several reasons:
Ensure that you are using the Proper Tester and Module Ident in ISO settings
Ensure that the PID added is supported by the vehicle or not
Disable Send start section and Sample only valid PID option in ISO settings
There could be several reasons:
Ensure that the GNSS bus is added to the configuration
Ensure that the GNSS antenna is interfaced with the logger
Ensure that the vehicle is not inside any location where a satellite signal is not available
If the CAN bus is logged along with GNSS, make sure that CAN Bus is active; if the CAN bus is not active, GNSS logging will stop after some time.
You can retrieve the data from the Rebel logger in two ways:
Using the Dialog software via USB cable from the Rebel Explorer option
Directly from the SD card by plugging it into the PC
Rebel Data loggers use Rechargeable batteries for the RTC; if the logger is not used for several weeks, the battery voltage will get low. You can plug the logger into a 12V power source and leave it for more than 12 hr to charge the cell. Once charged, you can set the time and confirm if the logger is keeping time. If the logger shows the wrong time, the battery might be dead and need to be replaced.
There could be several reasons:
Ensure that the SIM card is active and has sufficient data
Ensure that the GPRS/LTE antenna is connected to the logger
Check the Server and APN settings of the logger
Ensure the logger serial number is added to the StreamLog administration tab.
Test the connection with Streamlog Assistant. Refer Rebel Support page for the instruction manual.
The standard SLA period for Dialog Software is one year (Key-based and Dongle-based Licence can be purchased with a longer SLA duration); once the SLA period is complete, the software will start showing the Licence Expiry notification. Once the Licence expires, you will no longer be eligible to get New software or firmware updates. The GNSS Map overlay feature in Dialog Plus Version will be disabled as it is subscription-based. All the other functions will not be affected.
Ensure that the AUX Power settings are enabled in the configuration properties. Refer K-series Support page for more information.
A Flap protects the SD Card inside a Rebel CT logger. It can be opened by pressing the flap from the top and lifting it.
Influx Technology recommends Sandisk Extreme Pro SD cards for its data loggers.
F1. CAN 1 (MS) Bus traffic.
F2. Data Logger is configured and ready.
F3. Instrumentation/Trigger status.
F4. GPS status—flashes when acquiring data.
F5. CAN 0 (HS) Bus traffic.
Status. On—waiting, Flashing—Logging. Connect. They on—connected (USB/WIFI/LTE). SD Card. They are connected.
CN—Connect—ON—connected to StreamLog or DiaLog, Blinking—attempting to connect or active communication.