Before proceeding with the installation, please ensure you have acquired administrative privileges.
Make sure you have installed the Microsoft Visual C++ Redistributable (x86)
https://aka.ms/vs/17/release/vc_redist.x86.exe
Dotnet runtime 4.7.2 is required.
You can download it from the following link:
https://dotnet.microsoft.com/en-us/download/dotnet-framework/thank-you/net472-offline-installer
To begin with, install the K-Log software and open the installer by running the set-up file.
Click ' Next ' to continue installing the K-Log on your system.
To cancel the installation at this stage, click 'Cancel'. (No software will have been installed on the system now.)
Select the folder where you wish to install the software; using the default location is preferred.
Select the preference for computer user installation to determine which computer users will access the ReXdesk software.
Click 'Next' to continue with the installation.
Click 'Next' to confirm the installation.
Once the installation is complete, this window will appear.
Click 'Close' to close the window. K-Log has been successfully installed on your system.
The K-TC 2.0 is Influx's upgraded version of the older K-TC modules. Like the previous modules, these are stackable instrumentation devices compatible with Influx's entire range of data loggers. These can also be integrated with any device configured via DBC files, other logger systems, or output signals on CAN for the Rebel Dash display.
The K-TC 2.0 is an ideal solution for applications that require a large number of thermocouple inputs. The K-TC 2.0's accurate sensor data is transmitted periodically on the CAN bus, enabling multiple devices to be connected. In addition, The temperature data is simultaneously logged in the inbuilt micro SD card (8GB), the K-TC 2.0 CAN bus settings, calibration and sampling rates are all easily configurable, and these settings are stored within the K-TC 2.0 even when the device is not powered.
Power supply
4.5 to 31V DC (isolated)
Power consumption
K-TC8 / K-TC16 / K-TC32
Normal operation
120mA at 12V / 140mA at 12V / 200mA at 12V
Power down standby mode
24mA at 12V / 25mA at 12V / 30mA at 12V
Configuration
Via CAN bus with K-Cal for calibration. Via USB with TC Logger SW for logging configurations stored in the device
Interfaces (Isolated)
CAN bus (max 1000 kbps) and USB 2.0
Storage
8 GB eMMc
PC Interfaces
USB2.0 Type B (isolated)
Enclosure
Dimension (LxHxW): 115x56(K-TC8) / 79(K-TC16) / 149(K-TC32) x 105mm
Weight 450g(K-TC8), 570g(K-TC16), 900g(K-TC32)
IP 65 (With all thermocouples plugged in)
ABS/Aluminium Allow* (depending upon the stock availability)
Environmental
-40°C to +85°C
Humidity max 90%
Thermocouple Inputs
K, J, T-type
Accuracy ± 1°C
Measurement: -200 °C to 1250 °C
Connection type
Thermocouples: mini K, J ,T-Type (galvanically isolated)
Thermocouple Inputs
Number of channels
K-TC8: 8 channels, K-TC16: 16 channels, K-TC32: 32 channels (group of 8 thermocouples - each galvanically isolated)
Channel Input Types
K, J, T
Measurement Range
(-)200°C to (+)1200°C
Max Sampling Rate
20 Hz per channel
Max applied voltage
± 3.3 V
Peak Galvanic Isolation Voltage
(from all other modules and power supplies)
Three-wire CAN Bus
780 V
Four-wire USB Bus
840 V
Two-wire power module
560V
Before proceeding with the installation, please ensure you have acquired administrative privileges.
Run the TCXXInstaller.exe file.
Click ' Next ' to continue installing the TC logger device driver on your system.
To cancel the installation at this stage, click 'Cancel'. (No software will have been installed on the system now).
Once the installation is complete, this window will appear.
Click 'Finish' to close the window. The TCXX driver has now been successfully installed on your system.