The K-TC 2.0 is Influx's upgraded version of the older K-TC modules. Like the previous modules, these are stackable instrumentation devices compatible with Influx's entire range of data loggers. These can also be integrated with any device configured via DBC files, other logger systems, or output signals on CAN for the Rebel Dash display.
The K-TC 2.0 is an ideal solution for applications that require a large number of thermocouple inputs. The K-TC 2.0's accurate sensor data is transmitted periodically on the CAN bus, enabling multiple devices to be connected. In addition, The temperature data is simultaneously logged in the inbuilt micro SD card (8GB), the K-TC 2.0 CAN bus settings, calibration and sampling rates are all easily configurable, and these settings are stored within the K-TC 2.0 even when the device is not powered.
Before proceeding with the installation, please ensure you have acquired administrative privileges.
Make sure you have installed the Microsoft Visual C++ Redistributable (x86)
https://aka.ms/vs/17/release/vc_redist.x86.exe
Dotnet runtime 4.7.2 is required.
You can download it from the following link:
https://dotnet.microsoft.com/en-us/download/dotnet-framework/thank-you/net472-offline-installer
To begin with, install the K-Log software and open the installer by running the set-up file.
Click ' Next ' to continue installing the K-Log on your system.
To cancel the installation at this stage, click 'Cancel'. (No software will have been installed on the system now.)
Select the folder where you wish to install the software; using the default location is preferred.
Select the preference for computer user installation to determine which computer users will access the ReXdesk software.
Click 'Next' to continue with the installation.
Click 'Next' to confirm the installation.
Once the installation is complete, this window will appear.
Click 'Close' to close the window. K-Log has been successfully installed on your system.
Before proceeding with the installation, please ensure you have acquired administrative privileges.
Run the TCXXInstaller.exe file.
Click ' Next ' to continue installing the TC logger device driver on your system.
To cancel the installation at this stage, click 'Cancel'. (No software will have been installed on the system now).
Once the installation is complete, this window will appear.
Click 'Finish' to close the window. The TCXX driver has now been successfully installed on your system.
The 'Navigation Bar' is situated at the top of the software screen and can navigate most program features. Some of the menus will be active only when the logger is interfaced.
Technical Data | Description |
---|---|
Power supply
4.5 to 31V DC (isolated)
Power consumption
K-TC8 / K-TC16 / K-TC32
Normal operation
120mA at 12V / 140mA at 12V / 200mA at 12V
Power down standby mode
24mA at 12V / 25mA at 12V / 30mA at 12V
Configuration
Via CAN bus with K-Cal for calibration. Via USB with TC Logger SW for logging configurations stored in the device
Interfaces (Isolated)
CAN bus (max 1000 kbps) and USB 2.0
Storage
8 GB eMMc
PC Interfaces
USB2.0 Type B (isolated)
Enclosure
Dimension (LxHxW): 115x56(K-TC8) / 79(K-TC16) / 149(K-TC32) x 105mm
Weight 450g(K-TC8), 570g(K-TC16), 900g(K-TC32)
IP 40
ABS/Aluminium Allow* (depending upon the stock availability)
Environmental
-40°C to +85°C
Humidity max 90%
Thermocouple Inputs
K, J, T-type
Accuracy ± 1°C
Measurement: -200 °C to 1250 °C
Connection type
Thermocouples: mini K, J ,T-Type (galvanically isolated)
Thermocouple Inputs
Number of channels
K-TC8: 8 channels, K-TC16: 16 channels, K-TC32: 32 channels (group of 8 thermocouples - each galvanically isolated)
Channel Input Types
K, J, T
Measurement Range
(-)200°C to (+)1200°C
Max Sampling Rate
20 Hz per channel
Max applied voltage
± 3.3 V
Peak Galvanic Isolation Voltage
(from all other modules and power supplies)
Three-wire CAN Bus
780 V
Four-wire USB Bus
840 V
Two-wire power module
560V
Allows the user to import the saved TC settings file. |
Allows the user to save the working project (Projects are saved in .xml format). |
Allows the user to update the settings to the logger. |
Allow user to View internal storage. |
Allows the user to Set the Time of the TC device. |
The configuration panel comprises the available TC channels with respect to the device connected and the sampling rates for each Channel in the corresponding dropbox.
Users can also specify the names for each channel, which the K-Log software will use during data export.
The channel names and the rates will be saved with the configuration in xml format.
Users can import the configuration before exporting the data so that the data exported will have the labels specified by the user.
The Internal storage panel displays all the files currently stored on the TC Logger memory.
Refresh – Allows the user to refresh the window.
Download – Allows the user to retrieve log files from the TC logger memory.
Export – Allows the user to export the RAW data to various other export formats.
Show data log – Allows to view and then export the selected log data.
Format SD – Allows the user to format the internal memory of the data logger.
Find – Allows the user to search for log files.
This window allows the user to select an individual Channel required for exporting, select the Export format, Export options and Output Location.
Enabling "Use full date/time format" allows users to export data with actual time stamps (dd:mm:yyyy:hh:mm:ss).
K-log software allows the user to assign the temperature channels with different sampling rates.
Open K-Log software and interface TC logger with PC.
Select the sampling rate for each group of TC channels.
Enter the names for each of the channels.
Save the configuration to the PC, this XML will be used during the exporting of data for assigning channel names.
Click "Send Config" to update the configuration to the logger.
Pin No
Pin Function
Pin 1
NC
Pin 2
CAN - Low
Pin 3
CAN Ground
Pin 4
NC
Pin 5
Power GND
Pin 6
NC
Pin 7
CAN - High
Pin 8
NC
Pin 9
Power Supply 4.5 – 31V
Connect the logger to the PC via USB.
Status Bar will display the logger status and time information.
Click on the "Internal Storage"
The below window will open up:
Load the XML configuration, which contains the channel names.
The log files in the internal logger memory will be displayed.
Select the files to be retrieved.
Click Download to access the drop-down options. Click the 'Advanced' tab.
Clicking the 'Advanced' option tab opens the Export data window
General: click to define the output data format and the output file's location.
Input files: Click to verify the current input file in use.
File channels: click to select/deselect the channels from exporting their respective data. This also has quick check all and uncheck all tabs to select and deselect all the thermocouples at once.
Resampling: click to specify the sampling and synchronisation details.
Browse: click to specify the location for saving the exported data file.
Process: click to export data.
Cancel: click to terminate the entire process of exporting data.
Select the TC channel required for exporting from the 'File channels' window, and click 'Process'.
From the 'General tab' window, select the required output format.
Browse to specify a location to save the exported data.
Click 'Process' to export the file.
Max Logging Time – Allows the user to specify Max Log Duration for a data log.
This document provides a brief idea of the operation of the Influx K-TCxx loggers (INF 2204.02/05.02/06.02).
This document is intended for professional engineers and academic researchers, allowing them to understand the concept of operating the device and integrate this knowledge into systems with components of other manufacturers.
Translation of the original K-TC 2.0: User Manual & Quick Start Guide.
The content of this document, including all brands and trademarks and possibly protected by third-party rights, is subject without limitation to the terms of their respective registered owner’s valid trademark law and intellectual property rights.
© 2021 INFLUX TECHNOLOGY. All rights reserved.
If you have a problem that you cannot resolve on your own, feel free to contact us for assistance at docs.influxtechnology.com
Influx Technology Ltd
Millbrook Proving Ground, Station Lane
Bedford, MK45 2JQ, United Kingdom
Telephone: +44 (0) 1525 842504,
Sales: sales@influxtechnology.com
Support: docs.influxtechnology.com
The 'Status Bar' is used to display key pieces of information regarding the connected TC logger device.
Logger Status – Indicates the connection status of the TC logger.
TC model info – Displays the TC series of the connected device.
Firmware info – Displays the current firmware info of the connected device.
Logger serial number – Displays the serial number of the connected TC logger.
K-Log software is accessed using either the desktop icon:
Or the 'Start Menu' directory—"Influx Technology".
Once started, the user is presented with the following opening screen:
The datalog window will display the logged temperature data in the oscilloscope.