Technical Data
Description
Power supply
6 to 36V DC.
Interfaces
CAN Bus
PC interfaces
None
Enclosure
Dimension (L115xH46xW105)
Weight 450g/IP65/ABS
Environmental
-40°C to +85°C Humidity max 90%
Output voltages
5V and 24V (Max current drawn 80 mA combined)
Analog Inputs
Number of channels
8 Bipolar differential inputs
Accuracy
±0.0015%
Software switchable range
±80V, ±40V, ±20V, ±10V
Resolution (ADC)
16 Bit
Max Sampling Rate
(10 KHz) 2 channel, (5 KHz) 2 channel, (2 KHz) 4 channel, (1 KHz) 8 channel (Thermocouple and Digital Data will be turned off when rates above 1 ms are used for ADC channels.)
Input impedance
> 4 M Ohm
Max input voltage
±75 Analog Ground, ±50 V Analog inputs
Thermocouple Inputs
Number of channels
8 J/K/T-type inputs
Accuracy
±1°C accuracy
Measurement Range
Measurement: -200 °C to 1250 °C
Max Sampling Rate
10 Hz (all 8 channels)
Maximum input voltage
±3.3 V
Digital Input / Output
Number of channels
×4 unipolar single-ended hardware configured as inputs or outputs
Input switching thresholds
Low < 1.5V
High > 2.0V (up to 12V)
Input leakage current
< 10nA
Output states
(Optional) Open collector - 510 Ohm
Output drive capability (OK): Collector-emitter voltage
45V max
Collector current (DC)
10mA max
Saturation voltage (OK on)
< 0.15V
Equivalent on-resistance
< 510Ohm
Leakage current at OK off
< 5uA
Min-max applied voltage
Digital input -8V to +12V; Digital output 0V to +40V power supply, which limits the current to 10mA
PWM
3 digital input frequency measurements up to 100kHz or pulse measurements. (min 100 Nano sec) (between pulses 10 microseconds)
Connect the K-Box and IEPE devices. Connect the IEPE sensors to the IEPE0-3 channel.
Set the Additional board to Not Connected, Software ranges of odd channels to ±20V.
Connect the IEPE sensors, Keep the sensor in idle conditions, and Go to measurement mode.
Note down the measured value for ADC1 (IEPE 0), ADC3 (IEPE 1), ADC5 (IEPE 2) and ADC7 (IEPE 3) channels in mV.
Go to the Analog channel tab. Change the Additional board to IEPE, copy remembered values to the Offset edit box of each IEPE channel, and enter the sensitivity of the sensors.
Go to Measurement mode.
Then, export the DBC and import it into DiaLog software.
Make sure you select the combined option in the IEPE Transmit – Measure option.
The CAN connectors are 1x Male and 1x Female 9-pin Subminiature D Type connectors.
The ADC connector is a Male 25-pin Subminiature D Type connector.
The Thermocouple connectors on the K-Box are miniature-size flat-type sockets.
The dimensions of the Male Flat Type Miniature Size Thermocouple Plug that you would plug into it are as follows:
DB9
Pin Function
Pin 1
Digital 4/+4.5V inst
Pin 2
CAN L
Pin 3
Ground
Pin 4
Digital 1
Pin 5
Power Ground
Pin 6
Digital 3
Pin 7
CAN H
Pin 8
Digital 2
Pin 9
Power Supply 4.5-36V
DB25
Pin Function
Pin 1
+24V Output
Pin 2
+5V Output
Pin 5
Analog Ground
Pin 6
Analog Input 0 +
Pin 7
Analog Input 1 +
Pin 8
Analog Input 2 +
Pin 9
Analog Input 3 +
Pin 10
Analog Input 4 +
Pin 11
Analog Input 5 +
Pin 12
Analog Input 6 +
Pin 13
Analog Input 7 +
Pin 14
Ground Out
Pin 15
Ground Out
Pin 17
Analog Ground
Pin 18
Analog Input 0 -
Pin 19
Analog Input 1 -
Pin 20
Analog Input 2 -
Pin 21
Analog Input 3 -
Pin 22
Analog Input 4 -
Pin 23
Analog Input 5 -
Pin 24
Analog Input 6 -
Pin 25
Analog Input 7 -
IEC Connector
Pin Function
Top
+
Bottom
K
The K-Box may be connected to the multi-connect cable's AUX cable to connect it to the Rebel CT or LT Loggers. The pinout is as follows:
The Dig & An connector is a Female 15-pin Subminiature D Type connector.
Pin No
Pin Function
Pin 2
Digital Input or Output 1 - When used as an input, do not apply voltages outside the 0 to +12V range. When used as an Output, ensure that the current drawn is not more than 100mA. More information on the use of this pin can be found in Appendix 2 and 3
Pin 3
+4.5V Instrumentation Supply Voltage, ensure that current draw is not more than 100mA
Pin 4
Ground
Pin 6
Analog Ground
Pin 7
Analog Input 1 - do not apply voltages outside of the -10 to +10V range
Pin 8
Analog Input 3 - do not apply voltages outside of the -10 to +10V range
Pin 9
Digital Input or Output 0 - When used as Input, do not apply voltages outside the 0 to +12V range. When used as an Output, ensure that the current drawn is not more than 100mA. More information on the use of this pin can be found in Appendix 2 and 3
Pin 10
Digital Input or Output 2 - When used as Input, do not apply voltages outside the 0 to +12V range. When used as an Output, ensure that the current drawn is not more than 100mA. More information on the use of this pin can be found in Appendix 2 and 3
Pin 11
Ground
Pin 13
Wake-Up pin to wake logger from sleep mode (for use see Appendix 1)
Pin 14
Analog Input 0 - do not apply voltages outside of the -10 to +10V range
Pin 15
Analog Input 2 - do not apply voltages outside the -10 to +10V range.
The AUX/CAN1 connector is a Female 9-pin Subminiature D Type connector.
Pin No
Pin Function
Pin 2
CAN Bus 1 (Medium Speed Bus) Low Signal
Pin 3
Ground
Pin 5
Power Ground
Pin 7
CAN Bus 1 (Medium Speed Bus) High Signal
Pin 9
Power Supply Switched
The LAN connector is a Female 9-pin Subminiature D Type connector.
Pin No
Pin Function
Pin 1
LIN 0
Pin 2
CAN / CAN FD Bus 2 (Instrumentation Bus) Low Signal
Pin 3
Ground
Pin 5
Power Ground
Pin 7
CAN / CAN FD Bus 2 (Instrumentation Bus) High Signal
Pin 9
Digital Input or Output 3 (can also be used as a switched power supply +Vd). When used as Input, do not apply voltages outside of the 0 to +12V range.
The CAN0/PWR connector is a Male 9-pin Subminiature D Type connector.
Pin No
Pin Function
Pin 1
CAN Bus 1 (Medium Speed Bus) Low Signal
Pin 2
CAN Bus 0 (High Speed Bus) Low Signal
Pin 3
Ground
Pin 4
K-Line (1 wire bus) of ISO 9141
Pin 5
Power Ground
Pin 7
CAN Bus 0 (High Speed Bus) High Signal
Pin 8
CAN Bus 1 (Medium Speed Bus) High Signal
Pin 9
4.5-36V Supply Voltage
The CAN3/LIN1 is a Female 9-pin standard D-type connector with screws.
Pin No
Pin Function
Pin 1
LIN 1
Pin 2
CAN / CAN FD Bus 3 (Instrumentation Bus) Low Signal
Pin 3
Ground
Pin 5
Power Ground
Pin 7
CAN / CAN FD Bus 3 (Instrumentation Bus) High Signal
Pin 9
Digital Input or Output 3 (can also be used as a switched power supply +Vd). When used as Input, do not apply voltages outside of the 0 to +12V range.
The OBD&INST connector is a Female 25-pin Subminiature D Type connector.
Pin No
Pin Function
Pin 1
Analog Input 3 - do not apply voltages outside of the -10 to +10V range
Pin 2
LIN 1
Pin 3
CAN / CAN FD 3 L
Pin 4
Analog Input 1 - do not apply voltages outside of the -10 to +10V range
Pin 5
Wake-Up pin to wake logger from sleep mode (for use see Appendix 1)
Pin 6
CAN Bus 1 (Medium Speed Bus) Low Signal
Pin 7
CAN Bus 0 (High-Speed Bus) Low Signal
Pin 8
K-Line (1 wire bus) of ISO 9141
Pin 9
4.5-36V Supply Voltage
Pin 10
+4.5V Instrumentation Supply Voltage, ensure that current draw is not more than 100mA
Pin 11
Digital Input or Output 2 - When used as Input, do not apply voltages outside the 0 to +12V range. When used as an Output, ensure that the current drawn is not more than 100mA. More information on the use of this pin can be found in Appendix 2 and 3
Pin 12
Digital Input or Output 0 - When used as Input, do not apply voltages outside the 0 to +12V range. When used as an Output, ensure that the current drawn is not more than 100mA. More information on the use of this pin can be found in Appendix 2 and 3
Pin 13
CAN / CAN FD Bus 2 (Instrumentation Bus) Low Signal
Pin 14
Analog Input 2 - do not apply voltages outside of the -10 to +10V range
Pin 15
LIN 0
Pin 16
CAN / CAN FD 3 H
Pin 17
Analog Input 0 - do not apply voltages outside of the -10 to +10V range
Pin 18
Analog Ground
Pin 19
CAN Bus 1 (Medium Speed Bus) High Signal
Pin 20
CAN Bus 0 (High Speed Bus) High Signal
Pin 21
Ground
Pin 22
Power Ground
Pin 23
Digital Input or Output 3 (can also be used as a switched power supply +Vd)
Pin 24
Digital Input or Output 1 - When used as Input, do not apply voltages outside the 0 to +12V range. When used as an Output, ensure that the current drawn is not more than 100mA. More information on the use of this pin can be found in Appendix 2 and 3
Pin 25
CAN /CAN FD Bus 2 (Instrumentation Bus) High Signal