The K-TC is Influx’s stackable instrumentation that is compatible with the entire range of data loggers from Influx. It can also be integrated with any device configured via DBC files, even other logger systems or output signals on CAN to the Rebel Dash display.
The K-TC is an ideal solution for applications that require a large number of thermocouple inputs. The K-TC’s accurate sensor data is transmitted periodically on the CAN bus, enabling multiple devices to be connected. In addition, The temperature data is simultaneously logged in the inbuilt micro SD card, the K-TC CAN bus settings, calibration and sampling rates are all easily configurable, and these settings are stored within the K-TC even when the device is not powered.
Power supply
4.5V to 36V DC
Power consumption
Normal operation 150mA to 350mA at 12V
Power down standby mode approx. 3mA at 12V
Configuration
via CAN bus with K-Cal for calibration. via USB with TC Logger SW for logging.
Output control settings and configurations stored in the device
Interfaces
CAN bus (max 1000 kbps), USB 2.0
PC Interfaces
Power by USB2.0 Type B (isolated)
Enclosure
Dimension (LxHxW): 115x26(K-TC8), 46(K-TC16), 86(K-TC32) x 105mm
Weight 450g(K-TC8), 570g(K-TC16), 900g(K-TC32)
IP65
ABS
Environmental
-40°C to +85°C
Humidity max 90%
Thermocouple Inputs
K, J, T-type
Accuracy ± 1°C
Measurement: -200 °C to 1250 °C
Connection type
Thermocouples: mini K, J ,T-Type
Thermocouple Inputs
Number of channels
8 K, J, T-type inputs (K-TC8), 16 K, J, T-type inputs(K-TC16), 32 K, J ,T-type inputs (K-TC32)
Measurement Range
-200°C to +1200°C
Max Sampling Rate
20 Hz per channel
Max applied voltage
± 3.3 V
To begin with, install the TC logger software, and open the installer by running the set-up file.
To continue installing the TC logger on your system, click 'Next'.
To cancel the installation at this stage, click 'Cancel'. (No software will have been installed on the system now.)
Select the folder where you wish to install the software; using the default location is preferred.
Select the preference for computer user installation to determine which computer users will access the ReXdesk software.
Click 'Next' to continue with the installation.
Click 'Next' to confirm the installation.
Once the installation is complete, this window will appear.
Click 'Close' to close the window. TC logger is now successfully installed on your system
Before proceeding with the installation, please ensure that you have acquired administrative privileges.
Run the TCXXInstaller.exe file.
To continue installing the TC logger device driver on your system, click, 'Next'.
To cancel the installation at this stage, click 'Cancel'. (No software will have been installed on the system now).
Once the installation is complete, this window will appear.
Click 'Finish' to close the window. TCXX driver is now successfully installed on your system.