Technical Data | Description |
---|---|
Power supply
4.5 to 31V DC (isolated)
Power consumption
K-TC8 / K-TC16 / K-TC32
Normal operation
120mA at 12V / 140mA at 12V / 200mA at 12V
Power down standby mode
24mA at 12V / 25mA at 12V / 30mA at 12V
Configuration
Via CAN bus with K-Cal for calibration. Via USB with TC Logger SW for logging configurations stored in the device
Interfaces (Isolated)
CAN bus (max 1000 kbps) and USB 2.0
Storage
8 GB eMMc
PC Interfaces
USB2.0 Type B (isolated)
Enclosure
Dimension (LxHxW): 115x56(K-TC8) / 79(K-TC16) / 149(K-TC32) x 105mm
Weight 450g(K-TC8), 570g(K-TC16), 900g(K-TC32)
IP 40
ABS/Aluminium Allow* (depending upon the stock availability)
Environmental
-40°C to +85°C
Humidity max 90%
Thermocouple Inputs
K, J, T-type
Accuracy ± 1°C
Measurement: -200 °C to 1250 °C
Connection type
Thermocouples: mini K, J ,T-Type (galvanically isolated)
Thermocouple Inputs
Number of channels
K-TC8: 8 channels, K-TC16: 16 channels, K-TC32: 32 channels (group of 8 thermocouples - each galvanically isolated)
Channel Input Types
K, J, T
Measurement Range
(-)200°C to (+)1200°C
Max Sampling Rate
20 Hz per channel
Max applied voltage
± 3.3 V
Peak Galvanic Isolation Voltage
(from all other modules and power supplies)
Three-wire CAN Bus
780 V
Four-wire USB Bus
840 V
Two-wire power module
560V