Loading...
Loading...
Loading...
Loading...
Loading...
Loading...
Loading...
Pin No
Pin Function
Pin 1
LIN 0
Pin 2
CAN/CAN FD Bus 2 (Instrumentation Bus) Low Signal
Pin 3
Ground
Pin 5
Power Ground
Pin 7
CAN/CAN FD Bus 2 (Instrumentation Bus) High Signal
Pin 9
Digital Input or Output 3 (can also be used as a switched power supply +Vd). When used as an input do not apply voltages outside of the 0 to +12V range
Female 25-pin standard D-Type connector with screws
This 230 mm breakout cable is supplied with each Rebel CT data logger making it suitable to connect devices that are compliant with the standard CIA 9-pin D-Sub pinout directly to our data loggers.
The cable has one r, which connects directly to the Rebel CT data logger and four 9-Way D-Sub connectors to connect up to the separate CAN buses as described here:
enables power and a CAN bus to be connected to the Rebel data logger. Type
- 9-Way D-Sub (Plug)
enables a CAN bus to be connected to the Rebel data logger and can be used to supply auxiliary power from the Rebel data loggers to other devices. Type -9-Way D-Sub (Socket)
- 9-Way D-Sub (Socket)
- 9-Way D-Sub (Socket)
Additionally, a 15-Way D-Sub (Socket) connector enables easy connection to the data logger .
Parameter | Value |
Cable Length | 230mm |
Cable Thickness | 24 AWG 0.5 mm |
Connector A | 25-pin D-sub (DB25) socket, compatible with Rebel CT and Rebel LT data loggers |
Connector B | 9-pin D-sub (DB9) plug/nuts, pins compatible with CiA 303-1 (CAN0 and Power) |
Connector C | 9-pin D-sub (DB9) socket, pins compatible with CiA 303-1 (CAN 1) |
Connector D | 9-pin D-sub (DB9) socket, pins compatible with CiA 303-1 (CAN 2) |
Connector E | 9-pin D-sub (DB9) socket, pins compatible with CiA 303-1 (CAN 3) |
Connector F | 15-pin D-sub (DB15) socket, digital and analog inputs |
Temperature | Operating temperature: -20degC to +80degC |
Weight | 263 g |
Colour | Black |
Pin No
Pin Function
Pin 2
CAN Bus 1 (Medium Speed Bus) Low Signal
Pin 3
Ground
Pin 5
Power Ground
Pin 7
CAN Bus 1 (Medium Speed Bus) High Signal
Pin 9
Power Supply Switched
Pin No
Pin Function
Pin 1
Analog Input 3 - do not apply voltages outside of the -10 to +10V range
Pin 2
LIN 1
Pin 3
CAN/CAN FD 3 L
Pin 4
Analog Input 1 - do not apply voltages outside of the -10 to +10V range
Pin 5
Wake-Up pin to wake logger from sleep mode (for use see Appendix 1)
Pin 6
CAN Bus 1 (Medium Speed Bus) Low Signal
Pin 7
CAN Bus 0 (High Speed Bus) Low Signal
Pin 8
K-Line (1 wire bus) of ISO 9141
Pin 9
4.5-36V Supply Voltage
Pin 10
+4.5V Instrumentation Supply Voltage, ensure that current draw is not more than 100mA
Pin 11
Digital Input or Output 2 - When used as an input do not apply voltages outside of the 0 to +12V range, when used as an Output ensure that current draw is not more than 100mA.
More information on use ofthis pin can be found in Appendix 2 and 3
Pin 12
Digital Input or Output 0 - When used as an input do not apply voltages outside of the 0 to +12V range, when used as an Output ensure that current draw is not more than 100mA.
More information on use ofthis pin can be found in Appendix 2 and 3
Pin 13
CAN/CAN FD Bus 2 (Instrumentation Bus) Low Signal
Pin 14
Analog Input 2 - do not apply voltages outside of the -10 to +10V range
Pin 15
LIN 0
Pin 16
CAN/CAN FD 3 H
Pin 17
Analog Input 0 - do not apply voltages outside of the -10 to +10V range
Pin 18
Analog Ground
Pin 19
CAN Bus 1 (Medium Speed Bus) High Signal
Pin 20
CAN Bus 0 (High Speed Bus) High Signal
Pin 21
Ground
Pin 22
Power Ground
Pin 23
Digital Input or Output 3 (can also be used as a switched power supply +Vd)
Pin 24
Digital Input or Output 1 - When used as an input do not apply voltages outside of the 0 to +12V range, when used as an Output ensure that current draw is not more than 100mA.
More information on use ofthis pin can be found in Appendix 2 and 3
Pin 25
CAN/CAN FD Bus 2 (Instrumentation Bus) High Signal
Pin No
Pin Function
Pin 1
LIN 1
Pin 2
CAN CAN FD Bus 3 (Instrumentation Bus) Low Signal
Pin 3
Ground
Pin 5
Power Ground
Pin 7
CAN/CAN FD Bus 3 (Instrumentation Bus) High Signal
Pin 9
Digital Input or Output 3 (can also be used as a switched power supply +Vd). When used as an input do not apply voltages outside of the 0 to +12V range
Pin No
Pin Function
Pin 1
CAN Bus 1 (Medium Speed Bus) Low Signal
Pin 2
CAN Bus 0 (High Speed Bus) Low Signal
Pin 3
Ground
Pin 4
K-Line (1 wire bus) of ISO 9141
Pin 5
Power Ground
Pin 7
CAN Bus 0 (High Speed Bus) High Signal
Pin 8
CAN Bus 1 (Medium Speed Bus) High Signal
Pin 9
4.5-36V Supply Voltage
Pin No
Pin Function
Pin 2
Digital Input or Output 1 - When used as an input do not apply voltages outside of the 0 to +12V range, when used as an Output ensure that current draw is not more than 100mA.
More information on use of this pin can be found in Appendix 2 and 3
Pin 3
+4.5V Instrumentation Supply Voltage, ensure that current draw is not more than
100mA
Pin 4
Ground
Pin 6
Analog Ground
Pin 7
Analog Input 1 - do not apply voltages outside of the -10 to +10V range
Pin 8
Analog Input 3 - do not apply voltages outside of the -10 to +10V range
Pin 9
Digital Input or Output 0 - When used as an input do not apply voltages outside of the 0 to +12V range, when used as an Output ensure that current draw is not more than 100mA.
More information on use of this pin can be found in Appendix 2 and 3
Pin 10
Digital Input or Output 2 - When used as an input do not apply voltages outside of the 0 to +12V range, when used as an Output ensure that current draw is not more than 100mA.
More information on use of this pin can be found in Appendix 2 and 3
Pin 11
Ground
Pin 13
Wake-Up pin to wake logger from sleep mode (for use see Appendix 1)
Pin 14
Analog Input 0 - do not apply voltages outside of the -10 to +10V range
Pin 15
Analog Input 2 - do not apply voltages outside of the -10 to +10V range