The USB Connector is a USB Series "B" Receptacle Interface.
Pin No
Pin Function
Pin 1
VBUS USB supply voltage 5V
Pin 2
Data- line of USB, this signal utilises NRZI line coding
Pin 3
Data+ line of USB, this signal utilises NRZI line coding
Pin 4
Ground
The OBD & INST Connector is a Male 25-pin Standard D Type Connector with nuts.
Pin No
Pin Function
Pin 1
Analog Input 3- do not apply voltage outside of the -10 to +10 V range
Pin 2
LIN 1
Pin 3
CAN / CAN FD Bus 3 Low signal
Pin 4
Analog Input 1 - do not apply voltages outside of the -10 to +10V range
Pin 5
Wake-Up pin to wake logger from sleep mode (for use, see Appendix 1)
Pin 6
CAN Bus 1 (Medium Speed Bus) Low Signal
Pin 7
CAN Bus 0 (High-Speed Bus) Low Signal
Pin 8
NC
Pin 9
4.5-36V Supply Voltage
Pin 10
+4.5V Instrumentation Supply Voltage, ensure that the current drawn is not more than 100mA
Pin 11
Digital Input or Output 2 - Do not apply voltages outside of the 0 to +12V range when used as an input. When used as an Output, ensure that the current drawn is not more than 100mA.
More information on the use of this pin can be found in Appendix 2 and 3
Pin 12
Digital Input or Output 0 - Do not apply voltages outside the 0 to +12V range when used as an input. When used as an Output, ensure that the current drawn is not more than 100mA.
More information on the use of this pin can be found in Appendix 2 and 3
Pin 13
CAN /CAN FD Bus 2 (Instrumentation Bus) Low Signal
Pin 14
Analog Input 2 - - do not apply voltages outside of the -10 to +10V range
Pin 15
LIN 0
Pin 16
CAN / CAN FD Bus 3 High signal
Pin 17
Analog Input 0 - - do not apply voltages outside of the -10 to +10V range
Pin 18
Analog Ground
Pin 19
CAN Bus 1 (Medium Speed Bus) High Signal
Pin 20
CAN Bus 0 (High-Speed Bus) High Signal
Pin 21
Ground - e.g. to be connected to pin 5 of the OBDII Connector
Pin 22
Power Ground - e.g. to be connected to pin 4 of the OBDII Connector
Pin 23
Digital Input or Output 3 (can also be used as a switched power supply +Vd). Do not apply voltages outside of the 0 to +12V range when used as an input.
Pin 24
Digital Input or Output 1 - Do not apply voltages outside of the 0 to +12V range when used as an input. When used as an Output, ensure that the current drawn is not more than 100mA.
More information on the use of this pin can be found in Appendix 2 and 3
Pin 25
CAN / CAN FD Bus 2 (Instrumentation Bus) High Signal
DON'T SHORT CIRCUIT OR OVERLOAD AND DIGITAL I/O, e.g. IF USING DIGITAL INPUT OUTPUT 3 TO SUPPLY POWER TO POWER A K-BOX OR A REBEL DASH, DO NOT CONNECT MORE THAT 1 K-BOX TO THIS OUTPUT AND BE CAREFUL THAT NO SHORT CIRCUIT OCCURS.
OVERLOADING (I > 100mA) OF PIN 10 (+4.5V Instrumentation) WILL RESULT IN A DROP IN THE OUTPUT VOLTAGE.
The Optional GPS Connector is a Male SMB Connector.
Pin No
Pin Function
Pin 1
Radio Frequency Signal Input
Pin 2
Ground
The Optional GPRS Connector is a Male RP-SMA Connector.
Pin No
Pin Function
Pin 1
Radio Frequency Signal Input
Pin 2
Ground
The Optional WiFi Connector is a Female RP-SMA Connector.
Pin No
Pin Function
Pin 1
Radio Frequency Signal Input
Pin 2
Ground
The Optional FlexRay Connector is a Male 15-pin 1.27mm Pitch Micro D Connector nut.
Pin No
Pin Function
Pin 1
CAN Bus 4 (Ext 1) Low Signal
Pin 2
CAN Bus 4 (Ext 1) High Signal
Pin 3
CAN Bus 5 (Ext 2) Low Signal
Pin 4
CAN Bus 5 (Ext 2) High Signal
Pin 5
CAN Bus 6 (Ext 3) Low Signal
Pin 6
CAN Bus 6 (Ext 3) High Signal
Pin 7
LIN (Local Interconnect Network) Bus
Pin 8
+Vin Supply Voltage
Pin 9
FlexRay Bus 1 BP Signal
Pin 10
FlexRay Bus 1 BM Signal
Pin 11
FlexRay Bus 2 BP Signal
Pin 12
FlexRay Bus 2 BM Signal
Pin 13
Ground for the FlexRay Buses
Pin 14
Ground for the CAN and LIN Buses
Pin 15
Power Ground
The Rebel LT (RC5-2) (INF 2101)
The USB Connector is a USB Series “B” Receptacle Interface.
Pin No
Pin Function
Pin 1
VBUS USB supply voltage 5V
Pin 2
Data- line of USB this signal utilises NRZI line coding
Pin 3
Data+ line of USB this signal utilises NRZI line coding
Pin 4
Ground
The OBD & INST Connector is a Male 25-pin Standard D Type Connector nut.
Pin No
Pin Function
Pin 1
Analog Input 3 - do not apply voltages outside of the -10 to +10V range
Pin 2
NC
Pin 3
NC
Pin 4
Analog Input 1 - do not apply voltages outside of the -10 to +10V range
Pin 5
Wake-Up pin to wake logger from sleep mode (for use, see Appendix 1)
Pin 6
CAN Bus 1 (Medium Speed Bus) Low Signal
Pin 7
CAN Bus 0 (High-Speed Bus) Low Signal
Pin 8
K-Line (1 wire bus) of ISO 9141
Pin 9
4.5-36V Supply Voltage
Pin 10
+4.5V Instrumentation Supply Voltage, ensure that the current drawn is not more than 100mA
Pin 11
Digital Input or Output 2 - Do not apply voltages outside of the 0 to +12V range when used as an input. When used as an Output, ensure that the current drawn is not more than 100mA.
More information on the use of this pin can be found in Appendix 2 and 3
Pin 12
Digital Input or Output 0 - Do not apply voltages outside the 0 to +12V range when used as an input. When used as an Output, ensure that the current draw is not more than 100mA.
More information on the use of this pin can be found in Appendix 2 and 3
Pin 13
NC
Pin 14
Analog Input 2 - do not apply voltages outside of the -10 to +10V range
Pin 15
NC
Pin 16
NC
Pin 17
Analog Input 0 - do not apply voltages outside of the -10 to +10V range
Pin 18
Analog Ground
Pin 19
CAN Bus 1 (Medium Speed Bus) High Signal
Pin 20
CAN Bus 0 (High-Speed Bus) High Signal
Pin 21
Ground
Pin 22
Power Ground
Pin 23
Digital Input or Output 3 (can also be used as a switched power supply +Vd). When used as an input, do not apply voltages outside of the 0 to +12V range
Pin 24
Digital Input or Output 1 - Do not apply voltages outside of the 0 to +12V range when used as an input. When used as an Output, ensure that the current drawn is not more than 100mA.
More information on the use of this pin can be found in Appendix 2 and 3
Pin 25
NC
DON'T SHORT CIRCUIT OR OVERLOAD ANY DIGITAL I/O e.g. IF USING DIGITAL INPUT OR OUTPUT 3 TO SUPPLY TO POWER A K-BOX OR REBEL DASH, DO NOT CONNECT MORE THAN ONE K-BOX TO THIS OUTPUT AND BE CAREFUL THAT NO SHORT CIRCUIT OCCURS.
OVERLOADING (I > 100mA) ON PIN 10 (+4.5V Instrumentation) WILL RESULT IN A DROP IN THE OUTPUT VOLTAGE.
The Optional GPS Connector is a Male SMB Connector.
Pin No
Pin Function
Pin 1
Radio Frequency Signal Input
Pin 2
Ground
The Optional GPRS Connector is a Male RP-SMA Connector.
Pin No
Pin Function
Pin 1
Radio Frequency Signal Input
Pin 2
Ground