Functions | ReXgen 1 |
---|---|
CAN Interfaces
1 x CAN
ISO 11898-1: Compliant with CAN (up to 1 Mbit/s)
Conforms to CAN protocol version 2.0 - part A, B Max 20000 MPs
Meets the requirements of ISO 11898-2:2016 & ISO 11898-5:2007 physical layer standards
Identifiers
Compliant with CAN specifications 2.0A (11-Bit ID) and 2.0B (29-Bit ID)
CAN Error Frames
Support for logging CAN error frames (bit-stuffing, form, CRC, bit, acknowledgement)
Retransmission
Configurable retransmission of frames that have lost arbitration or been disturbed by errors
Prescaling
Pre-scale CAN frames to record e.g., by time (per X ms) or by data (e.g., if byte X or Y changes)
Transmit
Transmit lists of CAN frames per channel (periodic) - e.g., for OBD2 requests- Capability to link multiple CAN messages
PC Interfaces
Rugged Micro USB 2.0 (Datalogger mode and J2534)
J2534
Yes/Pass-Thru Enabled
Data Storage Capability
8 GB Inbuilt eMMC storage (uses FIFO logic once the eMMC is full)
Supported Protocols
CAN Monitoring (RAW CAN signals, SAE J1939 support)
Identifiers
Compliant with CAN specifications 2.0A (11-Bit ID) and 2.0B (29-Bit ID)
Bit-Rate Auto-Detect
Bit rate can be auto-detected or set manually
Real-Time Clock
Sync RTC using CAN Message and ReXdesk Software
File Split
Configurable log file split size (by size: 10-512 MB and/or by time period)
Unique Device ID
Each device has a globally unique ID ensuring unique log file naming
Signed Firmware
Firmware updates are digitally signed to verify that they are from a trusted source
Cyclic Logging
Enabled by default
LEDs
1
Triggering
Trigger on a CAN ID, Trigger on Parameter Value, and Trigger on DM1 counter.
Filters
200* regular/extended ID filters per channel (range, acceptance)
Data Storage format
FAT32, Log files accessible via ReXdesk software
File Format Supported
ASAM MDF (.mf4), CSV, MATLAB, ASC, BLF, TRC
Warranty
12 months from the date of invoice.
Support
Yes, during the warranty period
Origin
UK
Data Logger Configuration
Supplied with Influx ReXdesk configuration software, XML based