LED 1
Green
CAN0 Logging status
The device can effectively field log data on tests and a bench via the 1xCAN interface. The device supports all standard CAN baud rates. ReXdesk software allows users to configure ReXgen1 with custom baud rates and modify advanced bit timings. ReXdesk also enables the user to configure ReXgen1 with CAN & J1939 filters. All logged data is saved to the secure embedded memory. The user can configure triggers based on CAN IDs, parameter values & J1939 DM1 messages to start or stop logging.
For a step-by-step guide, here.
How to configure reXgen data logger to data.
FUNCTION
ReXgen1
Yes
Yes
The contents below specify the conditions to be ensured for the operation of ReXgen1.
GROUNDING
Since providing a common ground between nodes is not required, it is possible to have ground offsets between nodes. Each node may observe different single-ended bus voltages (common mode bus voltages) while maintaining the same differential voltage. Operating a CAN system with large ground offsets can increase electromagnetic emissions. If the system is sensitive to emissions, steps must be taken to eliminate ground offsets.
TERMINATION
ISO-11898 requires that the CAN bus have a nominal characteristic line impedance of 120Ω. Therefore, the typical terminating resistor value for each bus end is 120Ω. Bus termination is used to minimize signal reflection on the bus.
SUPPLY VOLTAGE
It is always recommended to keep the nominal voltage within the specified rate. The device also has internal protection against low energy voltage events due to supply wire noise.
ISOLATION
CAN Bus and USB are not isolated; care must be taken when plugging the USB into the device. Removing the power supply when the device is interfaced with a PC via a Micro USB cable is advised.
Notes:
The CAN Bus Isolator and USB Isolators can be purchased separately.
Do not use the logger's USB port for data logging purposes, as it may result in damaging the USB port, and this won't be covered under warranty.
MOUNTING
Always mount the device in a way that minimises vibration exposure and accounts for the IP rating of the device. ReXgen1 is supplied with four screws to assist you with the mounting process.
ReXgen1 comes with an integrated cable with a 9-pin D-Type connector.
Notes:
The connector needs to be tightened properly to make a proper connection, ensuring reliable operation.
Each end of the CAN bus must be terminated with a 120Ω resistor across CAN H & CAN L.
Do not short-circuit any pins.
Do not use the logger's USB port for data logging, as it may damage the USB port, which won't be covered under warranty.
PIN No DB9 (Male with Nuts) | PIN Function PWR/CAN0/Digital/LIN |
Pin 2 | CAN - Low |
Pin 3 | GND |
Pin 5 | Power GND |
Pin 7 | CAN - High |
Pin 9 | Power Supply 5-31V |
ReXgen1 is designed to function as a data logging device and a capable pass-thru device. The communication protocols supported by ReXgen1 as a J2534 tool are; ISO14229, ISO14230, CAN (ISO11898), ISO15765, and J1939.
It allows the users to connect to the vehicle CAN Bus using the Pass-Thru API (Application Program Interface), enabling you to create programs that accomplish your vehicle communication needs. Influx Module Analyser, SavvyCAN and K-Cal Software already support the pass-thru feature.
ReXgen J2534 (pass-thru) installation step-by-step guide.
Click to purchase these accessories.
Accessory
Part Number
Description
CAN Isolator
INF4313
External isolator for the CAN Bus.
USB Isolator
External isolator for the USB.
CAN Terminator
120Ω D Sub 9 CAN Terminator.
OBD II TYPE-B Cable to 9-way D-Sub
Cable for connecting to vehicle OBD port.
Multipower supply & CAN cable
This cable uses the vehicle's auxiliary power outlet or banana plugs (battery) for the power supply.