ReXgen Air uses:
FAKRA C connector (Blue) for the GNSS
FAKRA D connector (Bordeaux) for the LTE antenna.
Warning:
The device is not intended for use without the enclosure.
Do not use the logger's USB port for stand-alone data logging, as it may damage the USB port, which won't be covered under warranty.
Click to purchase.
The contents below specify the conditions to be ensured for the operation of ReXgen Air.
When inserting the SIM card in a ReXgen Air device, open the lid on the SIM slot correctly and carefully. Mishandling the SIM slot lid can damage the device and the SIM card inside.
Also, ensure the SIM is inserted, as shown in the images above (Chip facing down).
Since it is not required to provide a common ground between nodes, it is possible to have ground offsets. Each node may observe different single-ended bus voltages (common mode bus voltages) while maintaining the same differential voltage. Operating a CAN system with large ground offsets can increase electromagnetic emissions. If the system is sensitive to emissions, steps must be taken to eliminate ground offsets.
ISO-11898 requires that the CAN bus have a nominal characteristic line impedance of 120Ω. Therefore, the typical terminating resistor value for each bus end is 120Ω. Bus termination is used to minimise signal reflection on the bus.
It is always recommended to keep the nominal voltage within the specified rate. The device also has internal protection against low energy voltage events due to supply wire noise.
CAN Bus Isolators and USB Isolators can be purchased separately
Do not use the logger's USB port for stand-alone data logging, as it may damage the USB port, which won't be covered under warranty.
Always mount the device in a way that minimises vibration exposure and accounts for the IP rating of damage. Air is supplied with four screws to assist you with mounting.
An external active FAKRA C or FAKRA D antenna with a supply voltage of 3V is required for GNSS and LTE data logging. It is to be ensured that the antenna is connected correctly (at all times) and that it is not loose when the ReXgen Air is powered on. Operation with a loose antenna or without the antenna entirely can lead to GNSS/LTE data loss.
4 LEDs are installed on ReXgen Air for indicating the CAN/CAN FD logging activity.
Accessory
Part Number
Description
2-way Multi Connect Cable
INF4203
25-way D-sub (Female screw) breakout to two separate standard 9-way D-sub connectors.
5-way Multi Connect Cable
INF4204.1
25-way D-sub (Female screw) breakout to five (separate) standard 9-way D-sub connectors.
Molex mini50 (female) to D_Sub-25 (male)
INF4216
LED | Indication when BOLD | Indication when BLINKING |
LED 1 | Configured for CAN 0 Log | Slow Blinking: Logging on CAN 0 data Fast Blinking: CAN Error/Check connection/Incorrect Baud Rate. |
LED 2 | Configured for CAN 1 Log | Slow Blinking: Logging CAN 1 Data Fast Blinking: CAN Error/Check connection/Incorrect Baud Rate. |
LED 3 | Configured for GPS Log | GNSS Logging Active |
LED 4 | NA | Fast Blinking: Attempting to connect. Slow Blinking: Connected |
LED Blinking Patterns | Indication |
LED 1 and LED 2 - Blinking Alternatively | Firmware Reflashing in Progress |
All LEDs - Blinking Fast together | Pre-sleep mode |
The ReXgen Air has an automotive-style 24-pin Molex Connector. (This enables the device to be easily and robustly installed in production machines). Molex 24 PIN to D Sub 25 connector can be purchased separately.
*ReXgen Air requires an external antenna to be purchased in addition to the extension cable. The unit's price does not include the external antenna, which can be purchased off the shelf.
Male 25-pin Standard D Type connector (Mini 50 to D Sub 25 cable Sold separately).
The connector needs to be tightened properly to make a proper connection, ensuring reliable operation.
Each CAN/CAN FD bus end must be terminated with a 120 Ohm resistor across CAN H & CAN L.
Do not short-circuit any pins.
The maximum safe applied voltage for analog and digital I/P is ± 28 V.
Do not use the logger's USB port for stand-alone data logging, as it may damage the USB port, which won't be covered under warranty.
PIN No
PIN Function
Optional
Pin 1
RelayOut0
Relay Driver
Pin 2
DigIn0
--
Pin 3
AnalogGnd
--
Pin 4
Adc1
--
Pin 5
Wake-UP/Clamp-15
--
Pin 6
CAN0-L
--
Pin 7
CAN1-L
--
Pin 8
CAN2-L
Additional CAN FD 3rd bus
Pin 9
CAN3-L
Additional CAN FD 4th bus
Pin 10
usbDP_conn
Request when ordering
Pin 11
4.5Vout
--
Pin 12
DIgIn1
--
Pin 13
Adc0
--
Pin 14
Erase#
--
Pin 15
LIN
--
Pin 16
GND
--
Pin 17
PowerGND
--
Pin 18
5-31V
--
Pin 19
CAN0-H
--
Pin 20
CAN1-H
--
Pin 21
CAN2-H
Additional CAN FD 3rd bus
Pin 22
CAN3-H
Additional CAN FD 4th bus
Pin 23
usb5V
Request when ordering
Pin 24
usbDM_conn
Request when ordering
Pin No
Pin Function
Pin 3
CAN Bus 3 Low Signal (Available only on 4x CAN Model)
Pin 4
Analog Input 1 - do not apply voltages outside of the -10 to +10V range
Pin 5
Wake-Up pin to wake logger from sleep mode
Pin 6
CAN Bus 1 Low Signal
Pin 7
CAN Bus 0 Low Signal
Pin 9
5-31V Supply Voltage
Pin 10
+4.5V Instrumentation Supply Voltage, ensure that current draw is not more than 100mA
Pin 11
Erase PIN
Pin 12
Digital Input 0 - When used as an input, do not apply voltages outside the 0 to +12V range.
More information on the use of this pin can be found in Annexure 2
Pin 13
CAN Bus 2 Low Signal (Available only on 4x CAN Model)
Pin 15
LIN 0 Signal
Pin 16
CAN Bus 3 High Signal (Available only on 4x CAN Model)
Pin 17
Analog Input 0 - do not apply voltages outside of the -10 to +10V range
Pin 18
Analog Ground
Pin 19
CAN Bus 1 High Signal
Pin 20
CAN Bus 0 High Signal
Pin 21
Ground
Pin 22
Power Ground
Pin 23
Relay Out (Optional Feature)
Pin 24
Digital Input 1 - When used as input, do not apply voltages outside the 0 to +12V range
More information on the use of this pin can be found in Annexure 2
PIN 25
CAN Bus 2 High Signal (Available only on 4x CAN Model)
PCB Header
34897-8240
Mating Connector Details
2065230241
Terminals
5600230448