Download the latest version of our ReXdesk Software from the Influx Technology website.
Notes:
Before proceeding with the installation, please ensure you have acquired administrative privileges.
Make sure you have installed the Microsoft Visual C++ Redistributable.
You can download it from the following link:
https://www.microsoft.com/en-us/download/details.aspx?id=48145
To begin the installation of the ReXdesk Software, open the installer by running the set-up file.
To continue installing ReXdesk on your system, click 'Next'.
To cancel the installation at this stage, click 'Cancel' (No software will have been installed on the system now).
Select the folder where you wish to install the Software; it is preferred to use the default location.
Select the preference for computer user installation to determine which computer users can access the ReXdesk Software.
Click 'Next' to continue with the installation.
To continue with the installation of ReXdesk on your system, click 'Next'
Once the installation is complete, this window will appear.
Click 'Close' to close the window. ReXdesk is now successfully installed on your system.
To install the ReXgen driver, run the .exe file in this location:
C:\Program Files (x86) \Influx Technology\ReXdesk\Drivers.
To install the ReXgen1 driver, locate the ReXgen1 Drivers installer from the start menu.
Run the ReXgenInstaller.exe file.
Click 'Next' to install the ReXgen1 device driver on your system.
To cancel the installation at this stage, click 'Cancel' (No software will have been installed on the system now).
Please read the license agreement carefully.
Once you understand and accept the license agreement, please click 'I accept this EULA' to continue installing the driver. If you do not accept the terms, please click 'Cancel' to stop the installation at this point.
Click 'Next' to continue with the installation process.
Once the installation is complete, this window will appear.
Click 'Finish' to close the window. The ReXgen1 driver is now successfully installed on your system.
Firmware can be updated using the Reflash option in the ReXdesk Software.
The latest firmware can also be located here:
C:\Program Files (x86)\Influx Technology\ReXdesk\Firmware\RexFirmware.zip
Notes:
While re-flashing, the device's LEDs will flash alternatively; do not disconnect or change the power source during this process.
The device will disconnect from the PC while it is re-flashing. It will automatically reconnect once re-flashing is completed.
on updating the firmware of a ReXgen data logger.
Download the J2534 driver and execute the file.
Download the ReXgen J2534 driver installation guide
Click 'Install.'
After successful installation, the Windows Registry should contain J2534 ReXgen properties.
Attention:
A qualified technician must install, connect, and commission the device.
Ensure the power supply is disconnected before connecting the device.
Do not use the logger's USB port for data logging purposes, as it may damage the USB port, which won't be covered under warranty.
Only use components from the starter kits or the accessories supplied.
Power supply to the product is given using the male, 9-pin standard D-type connector.
Notes:
The connector needs to be tightened properly to make a proper connection, ensuring reliable operation.
Do not short-circuit any pins.
The maximum safe applied voltage is +34V.
ReXgen 1 can be interfaced to the CAN bus, from which data will be logged using D-Sub 9. The CAN-high and CAN-low from the vehicle or machine terminals must match the CAN-high and CAN-low terminal of the ReXgen1. ReXgen1 should be configured with the same baud rate as the device to which it is interfaced.
Notes:
The connector needs to be tightened properly to make a proper connection, ensuring reliable operation.
Each end of the CAN bus must be terminated with a 120Ω resistor across CAN H & CAN L.
Do not short-circuit any pins.
The maximum safe applied voltage is +28V.
CAN bus is not isolated by default; isolating devices can be purchased separately.
Do not use the logger's USB port for data logging purposes, as it may damage the USB port, which won't be covered under warranty.
USB can be used to interface and power the device as a PASS-THRU device. It will configure the device for data retrieval as a data logger.