Attention:
The device must be installed, connected, and commissioned by a qualified technician.
Ensure the power supply is disconnected before connecting the device.
Only use components from the starter kits or the accessories supplied.
Do not use the logger's USB port for data logging purposes, as it may damage the USB port, which won't be covered under warranty.
Power supply to the product is given using a Molex connector. DSub 9 or DSub 25 will be used if the customer uses the multi-connect cables. This is applicable to all the other connections mentioned below:
Notes:
The connector needs to be tightened properly to make a proper connection, ensuring reliable operation.
Do not short-circuit any pins.
The maximum safe applied voltage is +34V
Do not use the logger's USB port for data logging purposes, as it may damage the USB port, which won't be covered under warranty.
ReXgen Air can be interfaced to the CAN/CAN FD bus, from which data will be logged using D-Sub 9 connector A or connector B. The CAN-high and CAN-low from the vehicle or machine terminals must match the CAN-high and CAN-low terminal of the ReXgen Air. ReXgen Air should be configured with the same baud rate as the device to which it is interfaced.
Notes:
The connector needs to be tightened properly to make a proper connection, ensuring reliable operation.
Each end of the CAN/CAN FD bus must be terminated with a 120 Ohm resistor across CAN H & CAN L. Do not short circuit any pins.
The maximum safe applied voltage is +28V.
CAN/CAN FD bus is not isolated by default; isolating devices can be purchased separately.
Do not use the logger's USB port for data logging purposes, as it may damage the USB port, which won't be covered under warranty.
ReXgen Air supports 2x analogue inputs in the range of +/- 10 V. The two analogue inputs are interfaced to the ReXgen Air via a D-Sub 9 connector B. ReXgen Air also supports two digital inputs. The digital inputs are interfaced to the ReXgen Air via a D-Sub 9 connector A.
Notes:
The connector needs to be tightened properly to make a proper connection, ensuring reliable operation.
Do not short-circuit any pins.
The maximum safe applied voltage is +28V
Do not use the logger's USB port for data logging purposes, as it may damage the USB port, which won't be covered under warranty.
You can connect the device to a PC via the communication gateway USB for configuration and test purposes. The device is supplied with a standard Micro USB cable. Please note that the USB is not isolated; an isolator can be purchased separately.
*x1 micro USB cable to be supplied with any quantity of ReXgen Air purchased.
Download the latest version of our ReXdesk Software from the Influx Technology website.
Notes:
Before proceeding with the installation, please ensure that you have acquired administrative privileges.
Make sure you have installed the Microsoft Visual C++ Redistributable.
You can download it from the following link: https://www.microsoft.com/en-us/download/details.aspx?id=48145
To begin the installation of the ReXdesk Software, open the installer by running the set-up file.
To continue with the installation of ReXdesk on your system, click 'Next'.
To cancel the installation at this stage, click 'Cancel'. (No software will have been installed on the system at this point.)
Select the folder in which you wish to install the Software; it is preferred to use the default location.
Select the preference for computer user installation to determine which computer users will access the ReXdesk Software.
Click 'Next' to continue with the installation
To continue with the installation of ReXdesk on your system, click 'Next'.
Once the installation is complete, this window will appear.
Click 'Close' to close the window. ReXdesk is now successfully installed on your system.
All newly released firmware updates will be available in www.influxtechnology.com
Firmware can be updated using the Reflash option in the ReXdesk Software.
Choose the file with the prefix firmware628_xx_xx.bin
Notes:
While reflashing, the LEDs on the device will flash alternatively; do not disconnect or change the device's power source during this process.
The device will disconnect from the PC while it is reflashing. It will automatically reconnect once reflashing is completed.
To install the ReXgen driver, run the .exe file in this location:
C:\Program Files (x86) \Influx Technology\ReXdesk\Drivers.
To install the ReXgen1 driver, locate the ReXgen1 Drivers installer from the start menu.
Run the ReXgenInstaller.exe file.
Notes:
Before proceeding with the installation, please ensure you have acquired administrative privileges.
Run the ReXgenInstaller.exe file.
To continue installing the ReXgen Air device driver on your system, click 'Next'.
To cancel the installation at this stage, click 'Cancel'. (No software will have been installed on the system at this point.)
Please read the licence agreement carefully.
Once you understand and accept the licence agreement, please click 'I accept the terms in the licence agreement' to continue installing the driver. If you do not accept the terms, please click 'Cancel' to stop the installation at this point.
Click 'Next' to continue the installation process.
Once the installation is complete, this window will appear.
Click 'Finish' to close the window. The ReXgen Air driver has been successfully installed on your system.