Attention:
A qualified technician must install, connect, and commission the device.
Ensure the power supply is disconnected before connecting the device.
Do not use the logger's USB port for data logging purposes, as it may result in damaging the USB port, and this won't be covered under warranty.
Only use components from the starter kits or the accessories supplied.
Power supply to the product is given using connector A, the male, 9-pin standard D-type connector.
Notes:
The connector needs to be tightened properly to make a proper connection, ensuring reliable operation.
Do not short-circuit any pins.
The maximum safe applied voltage is +34V
Do not use the logger's USB port for data logging purposes, as it may result in damaging the USB port, and this won't be covered under warranty.
ReXgen2 can be interfaced to the CAN/CAN FD bus, from which data will be logged using D-Sub 9 connector A or connector B. The CAN-high and CAN-low from the vehicle or machine terminals must match the CAN-high and CAN-low terminal of the ReXgen2. ReXgen2 should be configured with the same baud rate as the device to which it is interfaced.
Notes:
The Connector must be tightened properly to make a proper connection, ensuring reliable operation.
Each CAN/CAN FD bus end must be terminated with a 120 Ohm resistor across CAN H & CAN L.
Do not short-circuit any pins.
The maximum safe applied voltage is +28V.
CAN/CAN FD bus is not isolated by default; isolating devices can be purchased separately.
Do not use the logger's USB port for data logging purposes, as it may result in damaging the USB port, and this won't be covered under warranty.
ReXgen2 supports 2 analog inputs in (the range of) ±10 V. The 2 analogue inputs are interfaced to the ReXgen2 via a D-Sub 9 connector B. ReXgen2 also supports two digital inputs. The digital inputs are interfaced to the ReXgen2 via a D-Sub 9 connector A.
Notes:
The connector needs to be tightened properly to make a proper connection, ensuring reliable operation.
Do not short-circuit any pins.
The maximum safe applied voltage is +28V
Do not use the logger's USB port for data logging purposes, as it may result in damaging the USB port, and this won't be covered under warranty.
For configuration and test purposes, you can connect the device to a PC via a USB communication gateway. The device is supplied with a standard Micro USB cable. Please note that the USB is not isolated; an isolator can be purchased separately.
Download the latest version of our ReXdesk Software from the Influx Technology website.
Notes:
Before proceeding with the installation, please ensure you have acquired administrative privileges.
Make sure you have installed the Microsoft Visual C++ Redistributable.
You can download it from the following link: https://www.microsoft.com/en-us/download/details.aspx?id=48145
To begin the installation of the ReXdesk Software, open the installer by running the set-up file.
To continue installing ReXdesk on your system, click 'Next'.
To cancel the installation at this stage, click 'Cancel' (No software will have been installed on the system now).
Select the folder where you wish to install the Software; it is preferred to use the default location.
Select the preference for computer user installation to determine which computer users can access the ReXdesk Software.
Click 'Next' to continue with the installation.
To continue installing ReXdesk on your system, click 'Next'.
Once the installation is complete, this window will appear.
Click 'Close' to close the window.
ReXdesk is now successfully installed on your system.
To install the ReXgen driver, run the .exe file in this location:
C:\Program Files (x86) \Influx Technology\ReXdesk\Drivers.
To install the ReXgen1 driver, locate the ReXgen1 Drivers installer from the start menu.
Run the ReXgenInstaller.exe file.
Notes:
Before proceeding with the installation, please ensure you have acquired administrative privileges.
Run the ReXgenInstaller.exe file.
Click 'Next' to continue installing the ReXgen device driver on your system.
To cancel the installation at this stage, click 'Cancel'. (No software will have been installed on the system now.)
Please Read the licence agreement carefully.
Once you understand and accept the licence agreement, please click 'I accept the EULA' to continue with the installation of the driver. If you do not accept the terms, please click 'Cancel' to stop the installation at this point.
Click 'Next' to continue the installation process.
Once the installation is complete, this window will appear.
Click 'Finish' to close the window. The ReXgen2 driver is now successfully installed on your system.
Firmware can be updated using the Reflash option in the ReXdesk Software.
Choose the file with prefix firmware628_xx_xx.bin
Notes:
While re-flashing, the LEDs on the device will flash; alternatively, do not disconnect or change the device's power source during this process.
The device will disconnect from the PC while it is re-flashing. It will automatically reconnect once re-flashing is completed.
Click 'Install.'
After successful installation, the Windows Registry should contain J2534 ReXgen properties.
All newly released firmware updates will be available on
and execute the file.
Download the