# Create and manage a Configuration in Dialog Software

To create a configuration, click the 'New Configuration' tab under the 'Configuration' tab and name the configuration.

![](/files/NaFh78MmlNypqD7mYFTj)

While performing this step, check the sleep mode settings to avoid battery drain.

* Use the drop-down menu to select the required mode.

![](/files/2Hyvy5YD3WvQiJAKqVoI)![](/files/qp6vvQJeq6kDbWw7bkSZ)

* Ensure that the 'Limit Module Wakeup' is not enabled, and then select 'OK'.

<div align="left"><figure><img src="/files/TNJt7yrkYfXK5LafYoHS" alt="" width="266"><figcaption></figcaption></figure></div>

Select the 'New Bus' tab.

<div align="left"><figure><img src="/files/qUFUDE3TZbc660bPWOXc" alt="" width="563"><figcaption></figcaption></figure></div>

Select CAN 0 (HS), and select 'OK'.

![](/files/sDbL8W8f0oZ1BtJFmDQn)

Select the drop-down CAN/bus speed menu, allocate the correct bus speed that matches your CAN network requirement, and then select 'OK'.

![](/files/yTGskz5WKCf7c0uebvoU)

Click on 'New Protocol', select the required option from the displayed choices, and click 'OK'.

<figure><img src="/files/wNHXYWJffG0At8yJOE85" alt=""><figcaption></figcaption></figure>

Select the 'CAN Monitor' protocol and then click 'OK'.

![](/files/06tiLYgtmHdZ9UwlQ76t)

Once the below screen appears, enable the checkbox in front of 'Log All Channels' and click 'OK' to proceed.

![](/files/Y1SAm5mInfiWNPSHMMPd)

Now connect your Rebel data logger using a USB cable and right-click to display, and click the 'Send Configuration to the Logger' option.

![](/files/FYeC2QFUhqQMG7NY4PyA)

Click 'Yes' to continue.

![](/files/Ybiexq3Y3QJ9Gi3PyW9c)

'Configuration uploaded' status is displayed on the 'Status message' (at the bottom left section) window once the processing is complete.

<div align="left"><figure><img src="/files/Mzh5Bu35lLLt6BRtDzz8" alt="" width="458"><figcaption></figcaption></figure></div>


---

# Agent Instructions: Querying This Documentation

If you need additional information that is not directly available in this page, you can query the documentation dynamically by asking a question.

Perform an HTTP GET request on the current page URL with the `ask` query parameter:

```
GET https://docs.influxtechnology.com/support_guides/dialog-user-guide/quick-start-guide/create-and-manage-a-configuration-in-dialog-software.md?ask=<question>
```

The question should be specific, self-contained, and written in natural language.
The response will contain a direct answer to the question and relevant excerpts and sources from the documentation.

Use this mechanism when the answer is not explicitly present in the current page, you need clarification or additional context, or you want to retrieve related documentation sections.