Page cover

ReXgen 2 FAQs

chevron-rightWhat happens if the logger storage gets full?hashtag

The logger can continue logging after deleting the first file on a FIFO basis or can stop logging and be configured via ReXdesk, which can format the logger. (FIFO is enabled by default.)

chevron-rightIs it possible to interface ReXgen 2 with KBOX?hashtag

Yes, It will work with Kbox, but you must power the KBox from a separate power source since ReXgen doesn’t have Auxilary Power Out.

chevron-rightWhere can I get the Driver installer?hashtag

It is available under the Influx technology folder in the Start menu.

chevron-rightWhere can I find the Pin out details for ReXgen 2?hashtag
chevron-rightWhat is the current consumption of ReXgen 2?hashtag

<87mA in full operation and <2mA when CAN is not active

chevron-rightHow to get real-time physical data?hashtag

ReXgen doesn't provide real-time physical data, user will have to retrieve the data log and post-process using a DBC file to view the physical data.

chevron-rightHow to enable Pass-thru funtionallity of a ReXgen logger (J2534)?hashtag