# Connecting and powering the K-Box

The K-Box is powered via the CAN and power connectors. It has been designed with CiA® 102 pinout for the CAN bus and power to connect the device as easily as possible.

&#x20;Most commonly, it will be powered from a Rebel Logger using the Multi-Connect Cable, but you can also power it via pin 9 (4.5 to 36V) and pin-5 PowerGND of the nine-pin Sub-D connectors. If connected via the Multi-connect cable, the CAN 1 (MS) bus is also connected, allowing the logger to record the data transmitted from the K-Box.

<div align="left"><figure><img src="/files/cIt2o7QP6RJSl3LbIeQE" alt=""><figcaption></figcaption></figure></div>

#### a) Setup for interfacing ReXgen Device with K-Box

<figure><img src="/files/XWXIuRmGY6KXk29YVT7K" alt=""><figcaption></figcaption></figure>

{% hint style="info" %}

#### Notes:

* When using a ReXgen Air device with K-Box device, be sure to get in touch with the technical support team at Influx.
  {% endhint %}

#### b) Setup for interfacing Rebel Device with K-Box.

<figure><img src="/files/6w0rjoYRG7xIRr84dQO0" alt=""><figcaption></figcaption></figure>

<figure><img src="/files/kws9t76kqU67AT84lRLt" alt=""><figcaption></figcaption></figure>

{% hint style="danger" %}
Warning:

* Several K-Boxes can be daisy chained via the additional DB9 Connector; however, they must have power supplied separately via power breakout in the Cable, not via the Logger. It can also be used to connect other devices, such as the Rebel Dash.
  {% endhint %}

<figure><img src="/files/IhJCKyuv9Fu7e9snwByE" alt=""><figcaption></figcaption></figure>

The pinout of the required Cable between the two K-Boxes is as follows:

<figure><img src="/files/4w0u96UhIRyheT9lhPrt" alt=""><figcaption></figcaption></figure>


---

# Agent Instructions: Querying This Documentation

If you need additional information that is not directly available in this page, you can query the documentation dynamically by asking a question.

Perform an HTTP GET request on the current page URL with the `ask` query parameter:

```
GET https://docs.influxtechnology.com/support_guides/k-series-product-manual/k-series-product-manual/k-box-product-manual/connecting-and-powering-the-k-box.md?ask=<question>
```

The question should be specific, self-contained, and written in natural language.
The response will contain a direct answer to the question and relevant excerpts and sources from the documentation.

Use this mechanism when the answer is not explicitly present in the current page, you need clarification or additional context, or you want to retrieve related documentation sections.