# Calibration

You can calibrate the K-TCxx to Improve the Accuracy of the measurements. The software allows you to cycle through a number of measurement points; once done, the calibration will apply the calibration to the K-TCxx, and measurement accuracy will be improved.

<figure><img src="/files/gbgCwgkwzpfqpFulsLAE" alt=""><figcaption></figcaption></figure>

<table data-header-hidden><thead><tr><th width="188"></th><th></th></tr></thead><tbody><tr><td><img src="/files/vmPUc8D8nkhS52IETKH3" alt=""></td><td><p>Pressing the Load Button Loads the calibration in the K-TCxx and displays it on the screen.</p><p>You may use this function if you wish to check that the K-TCxx is calibrated.</p></td></tr><tr><td><img src="/files/vpohup9kfyE3me3CVp7l" alt="" data-size="original"></td><td>Pressing the 'Notes' button will open the release notes containing all the details about the software's development.</td></tr><tr><td><strong>Nominal Value</strong></td><td>Allows the user to select the value being fed to the thermocouple channel.</td></tr><tr><td><strong>Raw Temperature</strong></td><td>Displays the RAW temperature data.</td></tr><tr><td><strong>Noise</strong></td><td>Displays the noise level in the signal.</td></tr><tr><td><strong>Settings</strong></td><td>Allows the user to set the Nominal temperature values.</td></tr><tr><td><strong>Noise Level</strong></td><td>Allows the user to set the tolerance level.</td></tr><tr><td><strong>Clear Calibration</strong></td><td>Clears the existing calibration in the device.</td></tr><tr><td><strong>Clear Channel</strong></td><td>Clears the calibration for the particular channel.</td></tr></tbody></table>

Alternatively, press the start button and attach the appropriate thermocouple test signals to the inputs of the K-TCxx to cycle through the test points to calibrate the K-TCxx for maximum accuracy.


---

# Agent Instructions: Querying This Documentation

If you need additional information that is not directly available in this page, you can query the documentation dynamically by asking a question.

Perform an HTTP GET request on the current page URL with the `ask` query parameter:

```
GET https://docs.influxtechnology.com/support_guides/k-series-product-manual/k-series-product-manual/k-tc-2.0-logger-manual-using-k-cal/software-introduction/interface-tab/calibration.md?ask=<question>
```

The question should be specific, self-contained, and written in natural language.
The response will contain a direct answer to the question and relevant excerpts and sources from the documentation.

Use this mechanism when the answer is not explicitly present in the current page, you need clarification or additional context, or you want to retrieve related documentation sections.