# ReXgen Air

<table data-view="cards"><thead><tr><th></th><th data-hidden data-card-target data-type="content-ref"></th></tr></thead><tbody><tr><td><mark style="color:blue;"><strong>PCB Header</strong></mark></td><td><a href="https://www.molex.com/molex/products/part-detail/pcb_headers/0348978240">https://www.molex.com/molex/products/part-detail/pcb_headers/0348978240</a></td></tr><tr><td><mark style="color:blue;"><strong>Mating Connector Details</strong></mark></td><td><a href="https://www.molex.com/molex/products/part-detail/crimp_housings/2065230241">https://www.molex.com/molex/products/part-detail/crimp_housings/2065230241</a></td></tr><tr><td><mark style="color:blue;"><strong>Terminals</strong></mark></td><td><a href="https://www.molex.com/molex/products/part-detail/crimp_terminals/5600230448">https://www.molex.com/molex/products/part-detail/crimp_terminals/5600230448</a></td></tr></tbody></table>

{% file src="/files/AKSl0UlGRZuA3dVpOOVd" %}

24-pin Molex Mini50 Connector

<figure><img src="/files/hgJ17Zhmz2peQ96hzYJV" alt=""><figcaption></figcaption></figure>

<table data-header-hidden><thead><tr><th width="170.33333333333331"></th><th width="189"></th><th></th></tr></thead><tbody><tr><td><strong>PIN No</strong></td><td><strong>PIN Function</strong></td><td><strong>Optional</strong></td></tr><tr><td>Pin 1</td><td>RelayOut0</td><td>Relay Driver</td></tr><tr><td>Pin 2</td><td>DigIn0</td><td> </td></tr><tr><td>Pin 3</td><td>AnalogGnd</td><td> </td></tr><tr><td>Pin 4</td><td>Adc1</td><td> </td></tr><tr><td>Pin 5</td><td>Clamp-15</td><td> </td></tr><tr><td>Pin 6</td><td>CAN0-L</td><td> </td></tr><tr><td>Pin 7</td><td>CAN1-L</td><td> </td></tr><tr><td>Pin 8</td><td>CAN2-L</td><td>Additional CAN FD 3rd bus</td></tr><tr><td>Pin 9</td><td>CAN3-L</td><td>Additional CAN FD 4th bus</td></tr><tr><td>Pin 10</td><td>usbDP_conn</td><td>Request when ordering</td></tr><tr><td>Pin 11</td><td>4.5Vout</td><td> </td></tr><tr><td>Pin 12</td><td>DIgIn1</td><td> </td></tr><tr><td>Pin 13</td><td>Adc0</td><td> </td></tr><tr><td>Pin 14</td><td>Erase#</td><td> </td></tr><tr><td>Pin 15</td><td>LIN</td><td> </td></tr><tr><td>Pin 16</td><td>GND</td><td> </td></tr><tr><td>Pin 17</td><td>PowerGND</td><td> </td></tr><tr><td>Pin 18</td><td>5V to 27V</td><td> </td></tr><tr><td>Pin 19</td><td>CAN0-H</td><td> </td></tr><tr><td>Pin 20</td><td>CAN1-H</td><td> </td></tr><tr><td>Pin 21</td><td>CAN2-H</td><td>Additional CAN FD 3rd bus</td></tr><tr><td>Pin 22</td><td>CAN3-H</td><td>Additional CAN FD 4th bus</td></tr><tr><td>Pin 23</td><td>usb5V</td><td>Request when ordering</td></tr><tr><td>Pin 24</td><td>usbDM_conn</td><td>Request when ordering</td></tr></tbody></table>

### Male 25-pin Standard D Type connector (Mini 50 to D Sub 25 cable Sold separately).

<figure><img src="/files/i4mcs2EzoVR00y5E40p7" alt=""><figcaption></figcaption></figure>

<table data-header-hidden><thead><tr><th width="153"></th><th></th></tr></thead><tbody><tr><td><strong>Pin No</strong></td><td><strong>Pin Function</strong></td></tr><tr><td>Pin 3</td><td>CAN Bus 3 Low Signal (Available only on 4x CAN Model)</td></tr><tr><td>Pin 4</td><td>Analog Input 1 - do not apply voltages outside of the -10 to +10V range</td></tr><tr><td>Pin 5</td><td>Wake-Up pin to wake logger from sleep mode (<a href="/pages/Ipz40scUIouuU5rtNwCX"><mark style="color:blue;">Appendix 1</mark></a>)</td></tr><tr><td>Pin 6</td><td>CAN Bus 1 Low Signal</td></tr><tr><td>Pin 7</td><td>CAN Bus 0 Low Signal</td></tr><tr><td>Pin 9</td><td>+5V to +27V Supply Voltage</td></tr><tr><td>Pin 10</td><td>+4.5V Instrumentation Supply Voltage, ensure that current draw is not more than 100mA</td></tr><tr><td>Pin 11</td><td>Erase PIN</td></tr><tr><td>Pin 12</td><td><p>Digital Input 0 - When used as an input, do not apply voltages outside the 0 to +12V range.</p><p>More information on the use of this pin can be found in <mark style="color:blue;">Appendix 2</mark></p></td></tr><tr><td>Pin 13</td><td>CAN Bus 2 Low Signal (Available only on 4x CAN Model)</td></tr><tr><td>Pin 15</td><td>LIN 0 Signal</td></tr><tr><td>Pin 16</td><td>CAN Bus 3 High Signal (Available only on 4x CAN Model)</td></tr><tr><td>Pin 17</td><td>Analog Input 0 - do not apply voltages outside of the -10 to +10V range</td></tr><tr><td>Pin 18</td><td>Analog Ground</td></tr><tr><td>Pin 19</td><td>CAN Bus 1 High Signal</td></tr><tr><td>Pin 20</td><td>CAN Bus 0 High Signal</td></tr><tr><td>Pin 21</td><td>Ground</td></tr><tr><td>Pin 22</td><td>Power Ground</td></tr><tr><td>Pin 23</td><td>Relay Out (Optional Feature)</td></tr><tr><td>Pin 24</td><td><p>Digital Input 1 - When used as input, do not apply voltages outside the 0 to +12V range</p><p>More information on the use of this pin can be found in <a href="/pages/FwF0X7uJlU51OplxaAla"><mark style="color:blue;">Appendix 2</mark></a></p></td></tr><tr><td>PIN 25</td><td>CAN Bus 2 High Signal (Available only on 4x CAN Model)</td></tr></tbody></table>

{% hint style="info" %}

#### Notes:

* The connector needs to be tightened properly to make a proper connection, ensuring reliable operation.
* Each end of the CAN bus must be terminated with a 120 Ohm resistor across CAN H & CAN L.&#x20;
* Do not short-circuit any pins.&#x20;
* The maximum safe applied voltage for analogue and digital I/P is ±28 V.
  {% endhint %}

{% hint style="warning" %}

#### Attention:

* To set up a USB via the Molex connector, please specify this requirement when ordering, or the device must be sent back to Influx (as this requires some hardware modification).
  {% endhint %}


---

# Agent Instructions: Querying This Documentation

If you need additional information that is not directly available in this page, you can query the documentation dynamically by asking a question.

Perform an HTTP GET request on the current page URL with the `ask` query parameter:

```
GET https://docs.influxtechnology.com/support_guides/pinouts-influx-product-range/cables-and-product-pinouts/rexgen-series/rexgen-air.md?ask=<question>
```

The question should be specific, self-contained, and written in natural language.
The response will contain a direct answer to the question and relevant excerpts and sources from the documentation.

Use this mechanism when the answer is not explicitly present in the current page, you need clarification or additional context, or you want to retrieve related documentation sections.
