# Technical Specifications

<table><thead><tr><th width="170">Functions</th><th width="510">Description</th></tr></thead><tbody><tr><td>Supported Protocols</td><td><p>OBD (CAN) ISO15765/ISO14229 (UDS)</p><p>CCP, xCPOnCAN </p><p>CAN monitoring (raw CAN messages or signals  via CAN DBC) </p><p>J1939 </p></td></tr><tr><td>CAN functions</td><td><p>Output CAN signals (applications include display units) </p><p>Create user-defined CAN messages for periodic transmission</p></td></tr><tr><td>Data storage format</td><td>FAT32 (PC readable)</td></tr><tr><td>Data logger configuration</td><td>Configuration  via  USB and SD card</td></tr><tr><td>Trigger Condition</td><td><p>Up to 20 configurable conditions</p><p>(>,&#x3C; ,=, increment, decrement or on-change)</p></td></tr><tr><td>TrIgger Action</td><td><p>Up to 20 configurable triggers </p><p>Functions include start or stop, sample one-shot data, sample DTC, and read OBD data. </p><p>Configurable pre and post-trigger times </p><p>Configurable LED functions</p></td></tr><tr><td>Wake up time</td><td><p>Wake up from normal sleep mode logging starts within 20mSec</p><p>Wake up from power down mode; logging starts &#x3C; 5 seconds</p></td></tr><tr><td>Data formats</td><td>Large quantities of recorded data can be conveniently converted to MDF, MDF4, MAT (Matlab), nCode, and by batch processing.</td></tr><tr><td>Power supply</td><td>4.7V to 36V DC  (12V typical) internally fused with reverse protection</td></tr><tr><td>Power consumption @12V</td><td><p>Normal operation approx. 250mA  to 350mA </p><p>Sleep mode approx. 80mA </p><p>Power down standby mode &#x3C; 2mA</p></td></tr><tr><td>Wake up</td><td>WakeOnCAN function</td></tr><tr><td>PC interfaces</td><td>Isolated USB2.0 (Type B) - can be powered by USB</td></tr><tr><td>CAN interfaces</td><td>2x CAN 2.0B Max 1MBit/s</td></tr><tr><td>LED</td><td>9x LEDs</td></tr><tr><td>Enclosure</td><td><p>Dimension (LxHxW): 115x26x105mm </p><p>Weight 400g </p><p>IP20</p><p>Stackable ABS</p></td></tr><tr><td>Environmental</td><td><p>-40degC to +80degC </p><p>Humidity max 90%</p></td></tr><tr><td>Data storage capability</td><td>Removable SDHC max 64GByte</td></tr><tr><td> </td><td>  <strong>Analog Inputs</strong></td></tr><tr><td>Number of channels</td><td>4 bipolar single-ended inputs</td></tr><tr><td>Range</td><td>±10V</td></tr><tr><td>Resolution (ADC)</td><td>12 bits</td></tr><tr><td>Max sampling rate</td><td>1 KHz</td></tr><tr><td>Input impedance</td><td>>50K Ohms</td></tr><tr><td>Min/Max applied voltage</td><td>±40V</td></tr><tr><td> </td><td><strong>Digital Inputs/Outputs</strong></td></tr><tr><td>Number of channels</td><td>3 unipolar single-ended inputs/outputs</td></tr><tr><td>Input switch thresholds</td><td>Low &#x3C; 2V, High > 2.5V (up to 36V)</td></tr><tr><td>Output Drive details</td><td><p>Collector-emitter voltage 36V </p><p>Collector current (DC) 50mA max</p><p>max Saturation voltage &#x3C;0.6V</p></td></tr><tr><td>Min-Max applied voltage</td><td>-0.5V to 36V</td></tr><tr><td>Optional</td><td>GNSS</td></tr></tbody></table>


---

# Agent Instructions: Querying This Documentation

If you need additional information that is not directly available in this page, you can query the documentation dynamically by asking a question.

Perform an HTTP GET request on the current page URL with the `ask` query parameter:

```
GET https://docs.influxtechnology.com/support_guides/rebel-series/rebel-series/rebel-lt-and-ct-user-documentation/the-rebel-lt-data-logger/technical-specifications.md?ask=<question>
```

The question should be specific, self-contained, and written in natural language.
The response will contain a direct answer to the question and relevant excerpts and sources from the documentation.

Use this mechanism when the answer is not explicitly present in the current page, you need clarification or additional context, or you want to retrieve related documentation sections.
