Appendix 4 – Using the LTE Debug Tool

ReXgen LTE Check Zip file

Notes:

Before you begin, ensure that:

  • ReXgen air device is fully powered, and the USB is connected to the laptop.

  • ReXdesk is not open when using this tool.

Create a configuration with AWS Upload and send it to the logger.

Close ReXdesk and open the Debug tool.

Click on “Connect Rexgen”.

The output should show “CONNECTED: 4”

Now click on Debug LTE Open; this will start the debugging process.

If the connection is successful, the output window will show

“### Status Send Start### Status Send OK”

Editable Example:

Or

*Some content in the output window will differ for different SIM providers and Amazon regions.

If the output doesn’t show Status Send OK, please copy the log, paste it into a text file and share it with Influx Technology support.

One Test is completed. Restart the logger entirely by removing the USB and full power to bring it to a normal state.

Last updated