# Appendix 4 – Using the LTE Debug Tool

[<mark style="color:blue;">**ReXgen LTE Check Zip file**</mark>](https://itltdgithub.s3.ap-south-1.amazonaws.com/RexgenLTECheck_v2.1.zip)

{% hint style="info" %}
**Notes:**

Before you begin, ensure that:

* &#x20;ReXgen air device is fully powered, and the USB is connected to the laptop.&#x20;
* ReXdesk is not open when using this tool.
  {% endhint %}

Create a configuration with AWS Upload and send it to the logger.

Close ReXdesk and open the Debug tool.

Click on “Connect Rexgen”.

<figure><img src="/files/5vlHULDeuydXJt30pOmi" alt=""><figcaption></figcaption></figure>

The output should show “CONNECTED: 4”

<figure><img src="/files/xaQIJFaAsdtQYSg0ELBd" alt=""><figcaption></figcaption></figure>

Now click on Debug LTE Open; this will start the debugging process.

<figure><img src="/files/LuuIxNXUrO111EAQAL0d" alt=""><figcaption></figcaption></figure>

&#x20;If the connection is successful, the output window will show

“### Status Send Start### Status Send OK”

<figure><img src="/files/s8ps2kSsP1IwTTpEgdHO" alt=""><figcaption></figcaption></figure>

Editable Example:

```
CONNECTED: 4
DEBUG LTE:1
ATE0
AT
ATOK
AT
ATOK
ATE0
ATE0OK
AT+IPR=6000000OK
+UMWI: 0,1
+UMWI: 0,2
+UMWI: 0,3
+UMWI: 0,4
AT+CREG?+CREG: 0,0
OK
AT+CREG?+CREG: 0,0
OK
AT+CREG?+CREG: 0,0
OK
AT+CREG?+CREG: 0,1
OK
AT+CGACT=1,1OK
AT+UPSD=0,100,1OK
AT+UPSDA=0,3
OK
+UUPSDA: 0,"10.80.102.137"
AT+CSQ+CSQ: 4,5
OK
AT+CTZU=1OK
AT+CCLK?
+CCLK: "24/10/14,18:50:25+22"
OK
AT+USOCR=17+USOCR: 0
OK
AT+USOST=0,"pool.ntp.org",123,48
@
+USOST: 0,48
OK
AT+USOCL=0
OK
AT+USOCR=6+USOCR: 0
OK
AT+USOSO=0,65535,8,1OK
AT+USOSO=0,6,2,1000OK
AT+USOCO=0,"40.80.82.175",9000
OK
AT+USODL=0
CONNECT
### Status Send Start### Status Send OK
DEBUG LTE Close:0

```

**Or**

<div align="left"><figure><img src="/files/wN86ld4noU2wfKl6XRDr" alt=""><figcaption></figcaption></figure></div>

\*Some content in the output window will differ for different SIM providers and Amazon regions.

If the output doesn’t show Status Send OK, please copy the log, paste it into a text file and share it with Influx Technology support.

One Test is completed. Restart the logger entirely by removing the USB and full power to bring it to a normal state.


---

# Agent Instructions: Querying This Documentation

If you need additional information that is not directly available in this page, you can query the documentation dynamically by asking a question.

Perform an HTTP GET request on the current page URL with the `ask` query parameter:

```
GET https://docs.influxtechnology.com/support_guides/rexdesk-configuration-software-s/rexdesk-rexgen-series-configuration-software/rexdesk-manual/appendix-4-using-the-lte-debug-tool.md?ask=<question>
```

The question should be specific, self-contained, and written in natural language.
The response will contain a direct answer to the question and relevant excerpts and sources from the documentation.

Use this mechanism when the answer is not explicitly present in the current page, you need clarification or additional context, or you want to retrieve related documentation sections.