# Start-up Guide: ReXgen Pro

### After reflashing, the logger will automatically reconnect to the software to download the ReXdesk software

1. Visit Influx Technology.com >> Support >> ReXgen Series >> [Software links ](/support_guides/software-links/software-links/rexdesk-software-links.md)>> ReXdesk Download
2. Windows Search  >>  [ReXgen Drivers](/support_guides/rexgen-series-product-manuals/rexgen-air-product-manual/rexgen-air-product-manual/getting-started/driver-installation.md) >> Select and Install

{% hint style="danger" %}

#### WARNING:

CAN Bus is not isolated.
{% endhint %}

{% hint style="info" %}

#### Notes:

* CAN Bus  Isolators can be purchased separately.
  {% endhint %}

### SIM CARD INSERTION (for devices with non-soldered SIM cards)

<div align="left"><figure><img src="/files/wOGREvq0hcEBQ9cfE5OU" alt="" width="375"><figcaption></figcaption></figure></div>

Also, ensure the SIM is inserted, as shown in the images above (Chip facing upwards).

### LED Indicators: The 8 LEDs on the ReXgen Pro indicate—&#x20;

<table data-header-hidden><thead><tr><th width="98" valign="top"></th><th width="104" valign="top"></th><th valign="top"></th></tr></thead><tbody><tr><td valign="top"><strong>LED</strong></td><td valign="top"><strong>Function</strong></td><td valign="top"><strong>Indication</strong></td></tr><tr><td valign="top"><strong>LED 1</strong></td><td valign="top"><strong>CAN 0</strong></td><td valign="top"><p><strong>Bold:</strong> CAN0 config active</p><p><strong>Slow Blinking:</strong> Logging CAN0 Data</p><p><strong>Fast Blinking:</strong> Baud Rate mismatch/CAN Error/Check connection</p></td></tr><tr><td valign="top"><strong>LED 2</strong></td><td valign="top"><strong>CAN 1</strong></td><td valign="top"><p><strong>Bold:</strong> CAN1 config active</p><p><strong>Slow Blinking:</strong> Logging CAN1 Data</p><p><strong>Fast Blinking:</strong> Baud Rate mismatch/CAN Error/Check connection</p></td></tr><tr><td valign="top"><strong>LED 3</strong></td><td valign="top"><strong>CAN 2</strong></td><td valign="top"><p><strong>Bold:</strong> CAN2 config active</p><p><strong>Slow Blinking:</strong> Logging CAN2 Data</p><p><strong>Fast Blinking:</strong> Baud Rate mismatch/CAN Error/Check connection</p></td></tr><tr><td valign="top"><strong>LED 4</strong></td><td valign="top"><strong>CAN 3</strong></td><td valign="top"><p><strong>Bold:</strong> CAN3 config active</p><p><strong>Slow Blinking:</strong> Logging CAN3 Data</p><p><strong>Fast Blinking:</strong> Baud Rate mismatch/CAN Error/Check connection</p></td></tr><tr><td valign="top"><strong>LED 5</strong></td><td valign="top"><strong>AIP</strong></td><td valign="top"><p><strong>Bold:</strong> Application Interface Platform is active</p><p>(any other pattern indicates possible faults)</p></td></tr><tr><td valign="top"><strong>LED 6</strong></td><td valign="top"><strong>GNSS</strong></td><td valign="top"><p><strong>Bold:</strong> GNSS Configured</p><p><strong>OFF:</strong> Not Configured</p><p><strong>Blinking</strong>: Valid Fix</p></td></tr><tr><td valign="top"><strong>LED 7</strong></td><td valign="top"><strong>LTE</strong></td><td valign="top"><p><strong>Bold:</strong> Connected to LTE</p><p><strong>OFF:</strong> No LTE connected</p><p><strong>Blinking:</strong> Data is transferred over the LTE interface</p></td></tr><tr><td valign="top"><strong>LED 8</strong></td><td valign="top"><strong>Wi-Fi</strong></td><td valign="top"><p><strong>Bold</strong>: Connected to Wi-Fi</p><p><strong>OFF:</strong> No interface connected</p><p><strong>Blinking</strong>: Data is transferred over the Wi-Fi interface</p></td></tr></tbody></table>

### ReXgen Pro Connector Details (JAE Compact Automotive 34-pin Connector)

<table data-header-hidden><thead><tr><th width="144"></th><th width="142"></th><th></th></tr></thead><tbody><tr><td> <strong>Pin</strong></td><td><strong>Function</strong></td><td><strong>Description</strong></td></tr><tr><td><strong>Pin 2</strong></td><td><strong>GND</strong></td><td>Ground </td></tr><tr><td><strong>Pin 3</strong></td><td><strong>Lin0</strong></td><td>LIN 0 </td></tr><tr><td><strong>Pin 11</strong></td><td><strong>Can0-L</strong></td><td>CAN0-Low Signal</td></tr><tr><td><strong>Pin 12</strong></td><td><strong>Can1-L</strong></td><td>CAN1-Low Signal</td></tr><tr><td><strong>Pin 13</strong></td><td><strong>Can2-L</strong></td><td>CAN2-Low Signal</td></tr><tr><td><strong>Pin 14</strong></td><td><strong>Can3-L</strong></td><td>CAN3-Low Signal</td></tr><tr><td><strong>Pin 18</strong></td><td><strong>6.5-27V</strong></td><td>6.5-27V Supply Voltage </td></tr><tr><td><strong>Pin 19</strong></td><td><strong>PowerGND</strong></td><td>Power Ground</td></tr><tr><td><strong>Pin 28</strong></td><td><strong>Can0-H</strong></td><td>CAN0-High Signal</td></tr><tr><td><strong>Pin 29</strong></td><td><strong>Can1-H</strong></td><td>CAN1-High Signal</td></tr><tr><td><strong>Pin 30</strong></td><td><strong>Can1-H</strong></td><td>CAN2-High Signal</td></tr><tr><td><strong>Pin 31</strong></td><td><strong>Can3-H</strong></td><td>CAN3-High Signal</td></tr></tbody></table>

### The JAE Compact automotive 34-pin Connector to D-sub 25 connector can be purchased separately. (Sold separately).

<table data-header-hidden><thead><tr><th width="135.25"></th><th width="143.5"></th><th></th></tr></thead><tbody><tr><td><strong>Pin</strong></td><td><strong>Function</strong></td><td><strong>Description</strong></td></tr><tr><td><strong>Pin 2</strong></td><td><strong>LIN2</strong></td><td>LIN 2 Signal </td></tr><tr><td><strong>Pin 3</strong></td><td><strong>Can3-L</strong></td><td>CAN Bus 3 Low Signal </td></tr><tr><td><strong>Pin 6</strong></td><td><strong>Can1-L</strong></td><td>CAN Bus 1 Low Signal </td></tr><tr><td><strong>Pin 7</strong></td><td><strong>Can0-L</strong></td><td>CAN Bus 0 Low Signal </td></tr><tr><td><strong>Pin 8</strong></td><td><strong>LIN1</strong></td><td>NC</td></tr><tr><td><strong>Pin 9</strong></td><td><strong>6.5-27V</strong></td><td>6.5-27V Supply Voltage  </td></tr><tr><td><strong>Pin 13</strong></td><td><strong>Can2-L</strong></td><td>CAN Bus 2 Low Signal </td></tr><tr><td><strong>Pin 15</strong></td><td><strong>LIN1</strong></td><td>LIN 1 Signal  </td></tr><tr><td><strong>Pin 16</strong></td><td><strong>Can3-H</strong></td><td>CAN Bus 3 High Signal </td></tr><tr><td><strong>Pin 18</strong></td><td><strong>GndA</strong></td><td>Analog Ground</td></tr><tr><td><strong>Pin 19</strong></td><td><strong>Can1-H</strong></td><td>CAN Bus 1 High Signal </td></tr><tr><td><strong>Pin 20</strong></td><td><strong>Can0-H</strong></td><td>CAN Bus 0 High Signal </td></tr><tr><td><strong>Pin 21</strong></td><td><strong>GND</strong></td><td>Ground</td></tr><tr><td><strong>Pin 22</strong></td><td><strong>PowerGND</strong></td><td>Power Ground</td></tr><tr><td><strong>Pin 23</strong></td><td><strong>+Vd</strong></td><td>Positive Drain Voltage </td></tr><tr><td><strong>Pin 25</strong></td><td><strong>Can2-H</strong></td><td>CAN Bus 2 High Signal </td></tr></tbody></table>

### RJ45 (Ethernet connector)

<table data-header-hidden><thead><tr><th width="129"></th><th width="145.25"></th><th></th></tr></thead><tbody><tr><td><strong>Pin</strong></td><td><strong>Function</strong></td><td><strong>Description</strong></td></tr><tr><td><strong>Pin 1</strong></td><td><strong>TrD1_P</strong></td><td>TX+_D1 (White with orange stripe)</td></tr><tr><td><strong>Pin 2</strong></td><td><strong>TrD1_N</strong></td><td>TX-_D1 (Orange with white stripe or solid orange)</td></tr><tr><td><strong>Pin 3</strong></td><td><strong>TrD2_P</strong></td><td>RX+_D2 (White with green stripe)</td></tr><tr><td><strong>Pin 6</strong></td><td><strong>TrD2_N</strong></td><td>RX-_D2 (Green with white stripe or solid)</td></tr></tbody></table>

{% hint style="info" %}

#### Notes:

* REFER TO THE PRODUCT MANUAL FOR DETAILED PINOUT.
  {% endhint %}

### How to configure Wi-Fi settings to start up REXGEN Pro.

{% hint style="info" %}
**Note:**

* The default password is **12345678**.
  {% endhint %}

<figure><img src="/files/FN9tbXcsFN5aaYS3jaOL" alt=""><figcaption></figcaption></figure>

Open the Wi-Fi settings on your device (laptop, mobile, or tablet).&#x20;\
Select the default serial number of your Pro device.&#x20;\
Select the Wi-Fi that you wish to connect to on the Wi-Fi configuration window, and click 'Configure'.

{% hint style="info" %}
**Note:**

* The default password is 12345678.
  {% endhint %}

Upon clicking Configure, the 'Wi-Fi hotspot' will get disconnected.

The status of LED 8 indicates the Wi-Fi configuration status. Once the hotspot connection is successful, LED 8 will turn bold after a one-minute pause.

Once the configuration is successful and the device is connected to the specified Wi-Fi.&#x20;

{% hint style="info" %}
**Note:**

* Ensure your system and the ReXgen Pro device are connected to the same Wi-Fi.
  {% endhint %}

* Once configured, open the ReXdesk software and click the USB icon on the status bar (located in the lower-left corner).

* Click on TCP/IP and scan for local networks.

* Scan Local Network.

* Select the name and IP of your Pro device, and click Connect.&#x20;

<figure><img src="/files/Wx0Jmgrwdp9XLmIrjNNL" alt=""><figcaption></figcaption></figure>

Click OK to exit the ReXgen Connect window.

Once completed, the status on the status bar is updated to 'CONNECTED'.

<figure><img src="/files/PVE5ylbmiCnqdiw38LGL" alt=""><figcaption></figcaption></figure>

### To update the firmware

Open ReXdesk, connect the logger and click the ‘Reflash’ option under the Device tab.

**Reflash** – Select the required firmware to update the logger.

![](/files/elv1k3T8KWbea7TlxorK)

{% hint style="info" %}

#### Notes:

* Do not disconnect the logger until the logger LED stops flashing. After reflashing, the logger will automatically reconnect to the software.
* Please ensure that the internal storage is formatted after reflashing the logger.
  {% endhint %}

### To set the time

* Open ReXdesk, connect the logger and click  ‘Set Time’ on the top taskbar.
* To synchronise the logger’s time with your PC, select ‘Synchronise with PC.&#x20;

**Or**

* To manually set the logger’s time, select ‘Set Custom Date Time’.
* Click ‘Set Time” to save.

### To start logging

* Open ReXdesk, connect the logger, double-click, or drag and drop the ‘Log All’ icon into the configuration window.
* Click the ‘Run’ icon on the top taskbar and save the project.
* Once the Configuration is uploaded successfully, click OK.

### To open a data log from internal storage

* Click the ‘Internal Storage’ icon on the top taskbar and select the file you wish to open.
* Click on the ‘Download’ tab and select the required format for download.

{% hint style="info" %}

#### Notes:

* Always ensure the device is installed, connected, and commissioned by a qualified professional.
* The device must only be repaired by the manufacturer.
  {% endhint %}

### &#x20;How to enable Cloud settings for the ReXgen Pro  logger

* &#x20;Click the Tool tab in the Navigation bar and select Cloud Settings.

&#x20;![](/files/Gj8Q15N98kH0BYGd8XTv)

* Select the Mobile option and then select the ‘New Mobile’ option.

<div align="left"><figure><img src="/files/t371wReohLL3dQLvBJ0D" alt="" width="294"><figcaption></figcaption></figure></div>

* Select the ‘S3 ‘option and the ‘New S3’ option.

&#x20;![](/files/oCeV1Am1z2ePqIWIkG9I)

### How to enable AWS configuration in the ReXgen logger

* &#x20;Prepare the base configuration for the logger.
* In the Device Configuration window, click on the 'Upload' tab.
* Enable the 'checkbox' for 'Enable AWS'.
  * For a single setting, details are auto-filled in the subsequent sections.
  * Users can select the desired setting from the corresponding drop-down menus for multiple settings.
* Click the ‘Run’ tab in the Navigation bar.
* Save the project:
  * Save Project: allows you to save the Project with a user-defined name.
  * Continue as "New Project”: saves the" New Project" configuration.
* Click ‘OK’ once the configuration is uploaded successfully.

### How do you upload the configuration to the logger via AWS?

* Make the new configuration.
* Enable AWS from the Device Configuration menu.

{% hint style="info" %}

#### Notes:

* Set your configuration check time in the given section.
  {% endhint %}

* Save the Project with the name you require for the configuration.

* Under the ‘Config’ tab, select Export from the drop-down menu.

* Select ‘Export ReXgen Configuration (rxc)’ from the listed options.

* Save the file with the desired name.

* Click ‘Save''.

* Once saved, rename the file as 'config.rxc.'

{% hint style="info" %}

#### Notes:

* Ensure that you rename the file as 'config.rxc' only.
  {% endhint %}

### How to [<mark style="color:blue;">configure Wi-Fi settings to start up a Pro</mark>](https://docs.influxtechnology.com/rexgen-series-product-manuals/rexgen-pro-product-manual/rexgen-pro-product-manual/annexures/configuring-wi-fi-setting-to-start-up-a-pro-device) device.


---

# Agent Instructions: Querying This Documentation

If you need additional information that is not directly available in this page, you can query the documentation dynamically by asking a question.

Perform an HTTP GET request on the current page URL with the `ask` query parameter:

```
GET https://docs.influxtechnology.com/support_guides/rexgen-series-product-manuals/rexgen-pro-product-manual/start-up-guide-rexgen-pro.md?ask=<question>
```

The question should be specific, self-contained, and written in natural language.
The response will contain a direct answer to the question and relevant excerpts and sources from the documentation.

Use this mechanism when the answer is not explicitly present in the current page, you need clarification or additional context, or you want to retrieve related documentation sections.