# ReXgen 2

The Influx ReXgen 2 is a small, robust, powerful CAN bus data recorder. Targeted at applications that require a CAN 2.0, CAN FD and LIN flight data recorder. Supplied with ReXdesk, freely distributable software for the ReXgen 2. used for logger configuration and file exporter.

<figure><img src="/files/sqBN9PRZOswx3pnuFIV6" alt="" width="563"><figcaption></figcaption></figure>

{% file src="/files/e41EpORfTxrU4RJ14b1d" %} <mark style="color:blue;">PDF Download</mark>
{% endfile %}

### &#x20;Key Features&#x20;

* 2x CAN 2.0/CAN FD buses, 1x LIN bus
* 2x Digital Input channels, 2x Analog Input channels
* Powerful graphic interface application tool
* Supported Data formats -ASAM MDF4 MATLAB (.mat), CSV, ASC, BLF & TRC
* Up to 16GByte eMMC storage
* Micro USB 2.0 -High-speed connection to logger
* Functions as an interface device and supports J2534 (Pass-thru)
* Supports CAN monitoring RAW CAN signals, SAE J1939
* Very low power consumption in sleep mode and  WakeOnCAN, WakeOnAlarm & WakeOnSignal
* CAN frame error detection ASAM MDF(\*.mf4 format) -international standard data format
* LEDs support status indication
* IP65 enclosure protection
* Plug and play, easily stackable and installable

### Technical Specifications

<table data-header-hidden><thead><tr><th width="232.33333333333331"></th><th></th><th data-hidden></th></tr></thead><tbody><tr><td><strong>Functions</strong></td><td><strong>ReXgen 2</strong></td><td><strong>ReXgen 2 IMU</strong></td></tr><tr><td>CAN Interfaces</td><td><p>2 x CAN/CAN FD</p><p>ISO 11898-1: Compliant with CAN (up to 1 Mbit/s)</p><p>ISO &#x26; Bosch CAN FD (up to 8 Mbit/s)</p><p>Conforms to CAN protocol version 2.0 - part A, B</p><p>Max 20000 mps</p><p>Meets the requirements of ISO 11898-2:2016 &#x26; ISO 11898-5:2007 physical layer standards</p></td><td><p>2 x CAN/CAN FD</p><p>ISO 11898-1: Compliant with CAN (up to 1 Mbit/s)</p><p>ISO &#x26; Bosch CAN FD (up to 8 Mbit/s)</p><p>Conforms to CAN protocol version 2.0 - part A, B</p><p>Max 20000 mps</p><p>Meets the requirements of ISO 11898-2:2016 &#x26; ISO 11898-5:2007 physical layer standards</p></td></tr><tr><td>CAN/CAN FD Functions</td><td><p>Supports custom baud rates</p><p>CAN/CAN FD Bit timing selection</p><p>SAE J1939 support (Source Address, Destination Address &#x26; PGN Filters)</p><p>Silent Mode Configurable</p><p>CAN DBC Support</p><p>CAN frame error detection</p></td><td><p>Supports custom baud rates</p><p>CAN/CAN FD Bit timing selection</p><p>SAE J1939 support (Source Address, Destination Address &#x26; PGN Filters)</p><p>Silent Mode Configurable</p><p>CAN DBC Support</p><p>CAN frame error detection</p></td></tr><tr><td>LIN Interface</td><td>1 x LIN (up to 20 K Baud with LIN-Compatible Output Driver)</td><td>1 x LIN (up to 20 K Baud with LIN-Compatible Output Driver)</td></tr><tr><td>Inputs</td><td>2 x Digital and 2 x Analog (max sampling rate-1KHz)</td><td>2 x Digital and 2 x Analog (max sampling rate-1KHz)</td></tr><tr><td>PC Interfaces</td><td><p>Rugged Micro USB 2.0</p><p>(Datalogger mode and J2534)</p></td><td><p>Rugged Micro USB 2.0</p><p>(Datalogger mode and J2534</p></td></tr><tr><td>Data Storage Capability</td><td>8 or 16 GB Inbuilt eMMC storage (uses FIFO logic once the eMMC is full)</td><td><p>16 or 32 GB Inbuilt eMMC</p><p> storage</p></td></tr><tr><td>Supported Protocols</td><td>CAN Monitoring (RAW CAN signals, SAE J1939 support)</td><td>CAN Monitoring (RAW CAN signals, SAE J1939 support)</td></tr><tr><td>LEDs</td><td>2</td><td>2</td></tr><tr><td>Triggering</td><td><p>Trigger on CAN ID, CAN Signal, and Digital Input.</p><p>Trigger on DM1 counter.</p></td><td><p>Trigger on CAN ID, CAN Signal, and Digital Input.</p><p>Trigger on DM1 counte</p></td></tr><tr><td>Data Storage Format</td><td>Log files accessible via ReXdesk Software</td><td>Log files accessible via ReXdesk Software</td></tr><tr><td>File Format Supported</td><td>ASAM MDF (.mf4), Peak TRC, CSV, MATLAB, ASC, BLF</td><td>ASAM MDF (.mf4), Peak TRC, CSV, MATLAB, ASC, BLF</td></tr><tr><td>Data Logger Configuration</td><td>Supplied with Influx ReXdesk configuration software, XML based</td><td>Supplied with Influx ReXdesk configuration software, XML based</td></tr><tr><td></td><td> <strong>Analog Input</strong></td><td><strong>Analog Input</strong></td></tr><tr><td>Number of channels</td><td>2 x Bipolar single-ended inputs</td><td>2 x Bipolar single-ended inputs</td></tr><tr><td>Range</td><td>± 10 V</td><td>± 10 V</td></tr><tr><td>Resolution (ADC)</td><td>12 Bit</td><td>12 Bit</td></tr><tr><td>Max sampling rate</td><td>1 kHz</td><td>1 kHz</td></tr><tr><td>Input Impedance</td><td>> 50 K Ohms</td><td>> 50 K Ohms</td></tr><tr><td>Safe Applied Voltage</td><td>± 28 V</td><td>± 28 V</td></tr><tr><td></td><td> <strong>Digital Input</strong></td><td><strong>Digital Input</strong></td></tr><tr><td>Number of channels</td><td>2 x Unipolar single-ended inputs</td><td>2 x Unipolar single-ended inputs</td></tr><tr><td>Input Switching Thresholds</td><td>Low &#x3C; 0.8 V, High > 2.5 V (up to 28V)</td><td>Low &#x3C; 0.8 V, High > 2.5 V (up to 28V)</td></tr><tr><td>Safe Applied Voltage</td><td>± 28 V</td><td>± 28 V</td></tr></tbody></table>

### Electrical Data

<table data-header-hidden><thead><tr><th width="231"></th><th></th></tr></thead><tbody><tr><td><strong>BUS &#x26; Signals</strong></td><td><strong>Operating Voltage</strong></td></tr><tr><td>Power supply - OBD</td><td>+5V to +27V</td></tr><tr><td>Power supply - USB</td><td>+4.5 to +5.5V</td></tr><tr><td>CAN FD</td><td>+2 to +3V</td></tr><tr><td>LIN</td><td>0 to +24V</td></tr><tr><td>Digital Input</td><td>0 to +28V</td></tr><tr><td>Analog input</td><td>± 10V</td></tr></tbody></table>

<table data-full-width="false"><thead><tr><th width="232">Function</th><th width="742">Description</th><th data-hidden></th></tr></thead><tbody><tr><td>Transceiver Protection(CAN)</td><td><p>Bus fault protection: ±58 V </p><p>Thermal-shutdown protection (TSD) </p><p>Common mode input voltage: ± 12V </p><p>TXD dominant timeout (prevents network blocking in the event of a failure)</p><p>Under-voltage protection</p></td><td><p>Bus fault protection: ±58 V </p><p>Thermal-shutdown protection (TSD) </p><p>Common mode input voltage: ± 12V </p><p>TXD dominant timeout (prevents network blocking in the event of a failure)</p><p>Under-voltage protection</p></td></tr><tr><td>Transceiver Protection (LIN)</td><td><p>±8 kV HBM ESD, ±2 kV CDM, ± bus Fault </p><p>TXD dominant timeout (to prevent the LIN node from permanently driving the LIN Bus dominant)</p></td><td><p>±8 kV HBM ESD, ±2 kV CDM, ± bus Fault </p><p>TXD dominant timeout (to prevent the LIN node from permanently driving the LIN Bus dominant)</p></td></tr><tr><td>Power Voltage</td><td>5V for external sensor (current consumed should be less than 10mAmp)</td><td>5V for external sensor (current consumed should be less than 10mAmp)</td></tr><tr><td>Enclosure</td><td>PC+ ABS</td><td>PC+ ABS</td></tr><tr><td>IP Rating</td><td>IP65</td><td>IP65</td></tr><tr><td>Dimension</td><td>L - 100 mm, W - 73.5 mm, H – 27.4 mm</td><td>L - 100 mm, W - 73.5 mm, H – 27.4 mm</td></tr><tr><td>Weight</td><td>164 gms</td><td>164 gms</td></tr><tr><td>Mounting Holes</td><td>4 mounting holes and screws</td><td>4 mounting holes and screws</td></tr><tr><td>Stackable</td><td>Yes</td><td>Yes</td></tr><tr><td>Environmental Tolerance</td><td>Working temperature -40degC to +85degC; Humidity max 90%</td><td>Working temperature -40degC to +85degC; Humidity max 90%</td></tr><tr><td>Silent Mode</td><td>Listen only mode available (configurable Silent mode)</td><td>Listen only mode available (configurable Silent mode)</td></tr><tr><td>Power Saving</td><td>Wake Up On CAN, Wake up on  Movement, Power Down Mode, Sleep Modes</td><td>Wake Up On CAN, Wake up on  Movement, Power Down Mode, Sleep Modes</td></tr><tr><td>Power Safe</td><td>100% power safe data logging - no file corruption when disconnected or in sleep mode</td><td>100% power safe data logging - no file corruption when disconnected or in sleep mode</td></tr><tr><td>Protection</td><td>Reverse voltage protection on CAN-bus supply</td><td>Reverse voltage protection on CAN-bus supply</td></tr><tr><td>Power Consumption</td><td><p>Normal Operation: &#x3C;75 mA at 12 V</p><p>Normal sleep &#x3C;17mA</p><p>Deep Sleep &#x3C;2 mA</p></td><td><p>Normal Operation: &#x3C;80 mA at 12 V</p><p>Normal sleep &#x3C;25mA </p><p>Deep Sleep &#x3C;2 mA</p></td></tr></tbody></table>

&#x20;\*Automotive customized connector is also available

[<mark style="color:blue;">**Detailed Documentation**</mark>](/support_guides/rexgen-series-product-manuals/rexgen-series.md)


---

# Agent Instructions: Querying This Documentation

If you need additional information that is not directly available in this page, you can query the documentation dynamically by asking a question.

Perform an HTTP GET request on the current page URL with the `ask` query parameter:

```
GET https://docs.influxtechnology.com/support_guides/technical-specifications/technical-specifications/rexgen-series/rexgen-2.md?ask=<question>
```

The question should be specific, self-contained, and written in natural language.
The response will contain a direct answer to the question and relevant excerpts and sources from the documentation.

Use this mechanism when the answer is not explicitly present in the current page, you need clarification or additional context, or you want to retrieve related documentation sections.