arrow-left

Only this pageAll pages
gitbookPowered by GitBook
1 of 17

Technical Specifications

Loading...

Loading...

Loading...

Loading...

Loading...

Loading...

Loading...

Loading...

Loading...

Loading...

Loading...

Loading...

Loading...

Loading...

Loading...

Loading...

Loading...

Technical Specifications

The following space contains the details about the Key features, advantages and technical specificatons of the Influx Products listed below.

ReXgen Series

ReXgen 1
ReXgen 2
ReXgen 2 IMU
ReXgen Air
ReXgen Pro

K-Series

K-Box
K-TC
K-AN8
K-IEPE
K-PT

Rebel Series

Rebel LT

Comparision List for ReXgen and Rebel Series data loggers

ReXgen Series

This space contains the technical specification details for all the Influx ReXgen devices.

Cover

ReXgen 1

Cover

ReXgen 2

Cover

ReXgen 2 IMU

Cover

ReXgen Air

Rebel Series

ReXgen pro

Cover

Rebel LT

Rebel LT

file-pdf
1MB
Rebel LT_flyer.pdf
PDF
arrow-up-right-from-squareOpen
PDF Download
Functions
Description

Supported Protocols

OBD (CAN) ISO15765/ISO14229 (UDS)

CCP, xCPOnCAN

CAN monitoring (raw CAN messages or signals via CAN DBC)

J1939

CAN functions

Output CAN signals (applications include display units)

Create user-defined CAN messages for periodic transmission

Data storage format

ReXgen Pro

Comparison List

For ReXgen and Rebel Series data loggers

Feature
ReXgen 1
ReXgen 2
ReXgen 2 IMU
ReXgen Air
Rebel LT
Rebel CT
Rebel CT CAN FD
Rebel CT Flexray

LTE CAT 1 Connectivity

âś–

âś–

âś–

âś”

Optional

Optional

Optional

Optional

Digital Inputs

âś–

2

2

2

3

3

3

3

CAN/CAN FD Bus

1x CAN

2x CAN FD

2x CAN FD

4x CAN FD

2x CAN

4x CAN

2x CAN FD/2x CAN

7x CAN

eMMC Storage

8 GB

8/16 GB

16/32 GB

16/32/64 GB

SD card up to 64 GB

SD card up to 128 GB

SD card up to 128 GB

SD card up to 128 GB

Starting Price

ÂŁ259

ÂŁ396.55

ÂŁ597.40

ÂŁ705

Contact Us

Contact US

Contact US

Contact US

Live CAN Bus Monitoring

âś”

âś”

âś”

âś”

âś”

âś”

âś”

âś”

Sleep & Wake On CAN

âś”

âś”

âś”

âś”

âś”

âś”

âś”

âś”

Analog Inputs

âś–

2

2

2

4

4

4

4

Trigger Functions

âś”

âś”

âś”

âś”

âś”

âś”

âś”

âś”

Over The Air Updates

âś–

âś–

âś–

âś”

âś–

âś–

âś–

âś–

Real Time Clock

âś”

âś”

âś”

âś”

âś”

âś”

âś”

âś”

GNSS Positioning System

âś–

âś–

âś”

âś”

Optional

Optional

Optional

âś”

FTPs for File Transfer

âś–

âś–

âś–

âś”

âś–

âś–

âś–

âś–

AWS S3

âś–

âś–

âś–

âś”

âś–

âś–

âś–

âś–

StreamLog*

âś–

âś–

âś–

âś–

âś”

âś”

âś”

âś”

IP Rating

IP 65

IP 65

IP 65

IP 50

IP 20

IP 65

IP 65

IP 65

USB 2.0 Interface

âś”

âś”

âś”

âś”

âś”

âś”

âś”

âś”

Open API

âś”

âś”

âś”

âś”

âś–

âś–

âś–

âś–

Supports J2534

âś”

âś”

âś”

âś”

âś”

âś”

âś”

âś”

Free Configuration Software ReXdesk

âś”

âś”

âś”

âś”

âś–

âś–

âś–

âś–

3D Accelerometer

âś–

âś–

âś”

âś”

Optional

Optional

Optional

âś”

LIN Bus

âś–

1

1

1

2

2

2

2

CAN Error Logging

âś”

âś”

âś”

âś”

âś”

âś”

âś”

âś”

Availability

Available Online

Available Online

Available Online

Enquire

Enquire

Enquire

Enquire

Enquire

J1939 Support

âś”

âś”

âś”

âś”

âś”

âś”

âś”

âś”

Gyroscope

âś–

âś–

âś”

âś”

Optional

Optional

Optional

Optional

Encryption Support (Licenced Feature)

âś”

âś”

âś”

âś”

âś”

âś”

âś”

âś”

FAT32 (PC readable)

Data logger configuration

Configuration via USB and SD card

Trigger Condition

Up to 20 configurable conditions

(>,< ,=, increment, decrement or on-change)

TrIgger Action

Up to 20 configurable triggers

Functions include start or stop, sample one-shot data, sample DTC, and read OBD data.

Configurable pre and post-trigger times

Configurable LED functions

Wake up time

Wake up from normal sleep mode logging starts within 20mSec

Wake up from power down mode; logging starts < 5 seconds

Data formats

Large quantities of recorded data can be conveniently converted to MDF, MDF4, MAT (Matlab), nCode, and by batch processing.

Power supply

4.7V to 36V DC (12V typical) internally fused with reverse protection

Power consumption @12V

Normal operation approx. 250mA to 350mA

Sleep mode approx. 80mA

Power down standby mode < 2mA

Wake up

WakeOnCAN function

PC interfaces

Isolated USB2.0 (Type B) - can be powered by USB

Functions

Description

CAN interfaces

2x CAN 2.0B Max 1MBit/s

LED

9x LEDs

Enclosure

Dimension (LxHxW): 115x26x105mm

Weight 400g

IP40

Stackable ABS

Environmental

-40degC to +80degC

Humidity max 90%

Data storage capability

Removable SDHC max 64GByte

Analog Inputs

Number of channels

4 bipolar single-ended inputs

Range

±10V

Resolution (ADC)

12 bits

Max sampling rate

1 KHz

Input impedance

>50K Ohms

Min/Max applied voltage

±40V

Digital Inputs/Outputs

Number of channels

3 unipolar single-ended inputs/outputs

Input switch thresholds

Low < 2V, High > 2.5V (up to 36V)

Output Drive details

Collector-emitter voltage 36V

Collector current (DC) 50mA max

max Saturation voltage <0.6V

Min-Max applied voltage

-0.5V to 36V

Optional

GNSS

Data Storage

32GB eMMC

Secure Element

Configurable

Wi-Fi

Murata 1MW Wi-Fi module

Wi-Fi Antenna

External FAKRA Code Z

LTE

CAT 4

LTE Antenna

FAKRA Code D

Data Transfer Protocol

Configurable app

Inputs

2x Digital and 3x Analog

Positioning & IMU Sensors

IMU

6 Axis accelerometer ( Max sampling rate 1KHz)

Accelerometer

±2/±4/±8/±16 g full scale (max sampling rate-1KHz)

Gyroscope

±125/±250/±500/±1000/±2000 dps full scale (max sampling rate-1KHz)

GNSS Antenna

FAKRA Code C

GNSS Receiver Type

72-channel, GNSS L1C/A, SBAS L1C/A, QZSS L1C/A, QZSS L1-SAIF, GLONASS L1OF, BeiDou B1I, Galileo E1B/C

Position Accuracy**

2.0 m CEP*

Acquisition**

Cold starts: 26s

Reacquisition: 2 s

GPS Accuracy**

Velocity: 0.05m/s

Heading: 0.3 degrees

Altitude: not specified

Clock

Battery backed RTC

Transceiver Protection

Bus fault protection: ±58 V

Thermal-shutdown protection (TSD)

Under-voltage protection

Enclosure

Aluminium

IP Rating

IP65

Dimension

L - 159.4mm, W - 81mm, H – 27.8mm

Weight

240g

Mounting Holes

4 mounting holes and screws

Environmental Tolerance

Working temperature -40degC to +70degC; Humidity max 90%

Power Saving

Power Down Mode, Sleep Modes Wake Up On CAN, Wake up on Movement, Digital Input,

Analog input

Number of channels

3 x Bipolar single-ended inputs

Range

± 10V

Resolution (ADC)

12 Bit

Max sampling rate

1 kHz

Input Impedance

> 50 K Ohms

Safe Applied Voltage

± 28 V

Digital Input

Number of channels

2 x Unipolar single-ended inputs (1x PWM)

Input Switching Thresholds

Low < 0.8 V, High > 2.5 V (up to 28V)

Safe Applied Voltage

±28 V

hashtag
LTE Modem Data

Integrated GPRS

LTE modem

Category

CAT 4 (Regional or Global)

SIM

Nano/ Soldered SIM (optional)

LTE CAT1 Bands

LTE FDD: B1/B2/B3/B4/B5/B7/B8/B12/B13/B18/B19/B20/B25/B26/B28 LTE TDD: B38/B39/B40/B41

Receiver input Sensitivity

hashtag
ELECTRICAL DATA

BUS & Signals

Operating Voltage

Power supply - OBD

6.5V to 27V

CAN FD

+2 to +3V

LIN

0 to +24V

Digital Input

Functions

ReXgen Air Pro

CAN Interfaces

Up to 4 x CAN/CAN FD (Arbitration Rate 500 Kbps & Data Rate 8 Mbps) ISO 11898-1: Compliant with CAN (up to 1 Mbit/s) ISO & Bosch CAN FD (up to 8 Mbit/s) Conforms to CAN protocol version 2.0 - part A, B Max 20000 mps Meets the requirements of ISO 11898-2:2016 & ISO 11898-5:2007 physical layer standards

CAN/CAN FD Functions

Supports custom baud rates CAN/CAN FD Bit timing selection Silent Mode Configurable CAN DBC Support CAN frame error detection

LIN Interface

2 x LIN (Master & Slave mode) (optional)

ReXgen 1

INF2109.01- Hardware Version- 8 GB

ReXgen 1
file-pdf
657KB
ReXgen1.pdf
PDF
arrow-up-right-from-squareOpen
PDF Download

hashtag
Key Features

  • Supports 1XCAN bus

  • Functions as an interface device and supports J2534 (Pass-thru)

  • Supports live CAN trace monitoring RAW CAN signals, SAE J1939

  • Sleep modes with wake-up on CAN and low power consumption

  • Encrypts data logs using Advanced Encryption Standard (AES)

  • Enables locking of the device using RSA data security

  • Open Libraries for logger management and data Conversion

  • XML-based configuration (Schema provided)

  • Free ReXdesk software that allows the user to export the loaded data to .mf4, .csv, mat, .asc, .blf, .trc and rxd format

  • Supports free firmware updates for adding features

  • Tolerable to harsh environments with an IP65 rating

  • Free powerful graphic interface application tool ReXdesk provided

  • Micro USB 2.0 PC interface

  • CAN error logging

hashtag
ReXgen 1’s additional features:

  • Efficiently records CAN bus data and advanced message filtering on configurable channels (J1939 and CAN)

  • Supports advanced triggering options and advanced CAN bit timing configuration.

  • The most compact, cost-effective, plug-and-play device operates as a CAN bus interface for real-time USB streaming and has 8GB eMMc storage (uses FIFO logic once the eMMc is full).

hashtag
Technical Specifications

K-Series

-98dBm to -114dBm: 700MHz to 2100MHz

Antenna

External FAKRA Code D

Interfaces

LTE CAT4, Wi-Fi (Bluetooth & Ethernet in future upgrades)

Supported Protocols

CAN or CAN FD Monitoring (RAW CAN signals, SAE J1939 support) UDS, OBD, XCP

LEDs

8

Triggering

Trigger on CAN ID, CAN Signal, and Digital Input.

Trigger on DM1 counter.

Log files accessible Via.

ReXdesk Software or on cloud

File Format Supported

ASAM, MDF, MF4, Peak TRC, CSV, MATLAB, ASC, BLF, RXD, Parquet

Data Logger Configuration

Supplied with Influx ReXdesk configuration software or XML-based Configuration

0 to +28V

Analog input

± 10V

file-pdf
1MB
K-Series Flyer.pdf
PDF
arrow-up-right-from-squareOpen
Downloadable pdfs for all K-Series instruments
Cover

K-Box

Cover

K-AN8

Cover

K-TC

Cover

K-IEPE

Cover

K-PT 100/1000

It supports cyclic logging mode and operates in silent mode.

Supported Protocols

CAN Monitoring (RAW CAN signals, SAE J1939 support)

LEDs

1

Triggering

Trigger on a CAN ID, Trigger on Parameter Value, Trigger on DM1 counter.

Data Storage format

FAT32, Log files accessible via ReXdesk software

File Format Supported

ASAM MDF (.mf4), CSV, MATLAB, ASC, BLF, TRC

Data Logger Configuration

Supplied with Influx ReXdesk configuration software, XML based

BUS & Signals

Operating Voltage

Power supply - OBD

+5V to +27V

Power supply - USB

+4.5 to +5.5V

Transceiver Protection

Bus fault protection: ±58 V Thermal-shutdown protection (TSD)

Under-voltage protection

Enclosure

PC+ ABS

IP Rating

IP65

Dimension

L - 100 mm, W - 73.5 mm, H – 27.4 mm

Weight

164 Grams

Mounting Holes

Four mounting holes and screws

Environmental Tolerance

Working temperature -40degC to +85degC; Humidity max 90%

Power Saving

Wake Up On CAN, Power Down Mode, Sleep Modes,

Power Consumption

Normal Operation: 87 mA at 12 V

Normal Sleep <17mA

Deep Sleep: <2 mA

Functions

ReXgen 1

CAN Interfaces

1 x CAN

ISO 11898-1: Compliant with CAN (up to 1 Mbit/s)

Conforms to CAN protocol version 2.0 - part A, B Max 20000 MPs

Meets the requirements of ISO 11898-2:2016 & ISO 11898-5:2007 physical layer standards

PC Interfaces

Rugged Micro USB 2.0 (Datalogger mode and J2534)

Data Storage Capability

8 GB Inbuilt eMMC storage (uses FIFO logic once the eMMC is full)

ReXgen Oem

Functions
ReXgen Smart

RAM

2GB

Storage

8GB ©

Processor

NXP imx8mini Application Series Quad core processor

OS/Configuration

Yocto based Linux

Secure Element

On Request

Socket CAN

Supported

Bluetooth

Murata 1MW Bluetooth® 5.0 BR/EDR/LE module

WiFi

Murata 1MW WiFi module

Wifi Antenna

External FAKRA Code E

LTE

CAT 1 (mention the chip) or CAT 4 or NB-IoT

Data Transfer Protocol

Any

Inputs

2x Digital and 3x Analog

Positioning & IMU Sensors

IMU

6 Axis ( Max sampling rate 1KHz)

GNSS

Neo M8 Series or Neo M9 Series (18Hz)

GNSS Receiver Type

72-channel, GNSS L1C/A, SBAS L1C/A, QZSS L1C/A, QZSS L1-SAIF, GLONASS L1OF, BeiDou B1I, Galileo E1B/C

Position Accuracy

2.0 m CEP*

Acquisition

Cold starts: 26s

Reacquisition: 2 s

Antenna

External FAKRA Code C

Accuracy

Velocity: 0.05m/s

Heading: 0.3 degrees

Altitude: not specified

Accelerometer

±2/±4/±8/±16 g full scale(max sampling rate-1KHz)

Gyroscope

±125/±250/±500/±1000/±2000 dps full scale (max sampling rate-1KHz)

PC Interfaces

Rugged Micro USB 2.0 (Datalogger mode and J2534)

Data Storage Capability

Logger (variable 4*) and LINUX (8GB)

Supported Protocols

CAN Monitoring (RAW CAN signals, SAE J1939 support)

LEDs

2

Triggering

Trigger on CAN ID, CAN Signal, and Digital Input.

Trigger on DM1 counter.

Data Storage Format

Log files accessible via ReXdesk Software

File Format Supported

ASAM MDF (.mf4), Peak TRC, CSV, MATLAB, ASC, BLF

Data Logger Configuration

Supplied with Influx ReXdesk configuration software, XML based Configuration

Analog Input

Number of channels

2 x Bipolar single-ended inputs (1x connected to Power supply)

Range

± 10V

Resolution (ADC)

12 Bit

Max sampling rate

1 kHz

Input Impedance

> 50 K Ohms

Safe Applied Voltage

± 28 V

Digital Input

Number of channels

2 x Unipolar single-ended inputs

Input Switching Thresholds

Low < 0.8 V, High > 2.5 V (up to 28V)

Safe Applied Voltage

±28 V

Transceiver Protection

Bus fault protection: ±58 V

Thermal-shutdown protection (TSD)

Under-voltage protection

Enclosure

PC+ ABS

IP Rating

Build to order

Dimension

L - 100 mm, W - 73.5 mm, H – 27.4 mm

Weight

240gms

Mounting Holes

4 mounting holes and screws

Stackable

Yes

Environmental Tolerance

Working temperature -40degC to +85degC; Humidity max 90%

Power Saving

Wake Up On CAN, Wake up on Momnet, Digital Input, Power Down Mode, Sleep Modes

Power Consumption

Normal Operation: 250 mA to 300 mA at 12 V

Power Down Mode: 4.8 mA at 12 V

hashtag
LTE Modem Data

Integrated GPRS

LTE modem

Category

LTE CAT 1 or 4 or NB-IoT

SIM

Nano/E-SIM

LTE CAT1 Bands

LTE FDD Bands: 1(2100 MHz) ,2(1500 MHz), 3(1800 MHz),4(1700 MHz), 7(2600 MHz), 8(900 MHz), 12(700 MHz), 13(700 MHz), 19(850 MHz), 20(800 MHz), 28(700 MHz)

Receiver input Sensitivity

hashtag
ELECTRICAL DATA

BUS & Signals
Operating Voltage

Power supply - OBD

5V to 27V

Power supply - USB

+4.5 to +5.5V

CAN FD

+2 to +3V

LIN

CAN Interfaces

Up to 4 x CAN/CAN FD (Arbitration Rate 500 Kbps & Data Rate 8 Mbps)

ISO 11898-1: Compliant with CAN (up to 1 Mbit/s)

ISO & Bosch CAN FD (up to 8 Mbit/s)

Conforms to CAN protocol version 2.0 - part A, B

Max 20000 mps

Meets the requirements of ISO 11898-2:2016 & ISO 11898-5:2007 physical layer standards

CAN/CAN FD Functions

Supports custom baud rates

CAN/CAN FD Bit timing selection

SAE J1939 support (Source Address, Destination Address & PGN Filters)

Silent Mode Configurable

CAN DBC Support

CAN frame error detection

LIN Interface

1 x LIN (Master & Slave mode) (optional)

-98dBm to -114dBm: 700MHz to 2100MHz

Antenna

External FAKRA Code D

0 to +24V

Digital Input

0 to +28V

Analog input

± 10V

K-TC

INF2204.02/INF2205.02/INF2206.02

The K-TC 2.0 modules belong to the Influx K-series instrumentation range for CAN applications and are stackable, fast, accurate and reliable temperature measurement devices. Ideal for applications requiring many thermocouples, such as vehicle durability during winter and summer testing.

The K-TC 2.0 modules CAN Bus settings, calibration and sampling rates are all easily configurable and stored in the K-TC 2.0 module even when not powered.

The input calibration and set-up of the K-TC 2.0 module are easily configurable via freely distributable Windows PC applications, Influx K-Cal and TC Logger software.

Logs and stores data to an integrated memory card independently (without the support of any other data logger).

K-TC 8/16/32
file-pdf
682KB
K-Tc Flyer.pdf
PDF
arrow-up-right-from-squareOpen
PDF Download

hashtag
Key Features

  • Each K-TC 2.0 unit has up to 8, 16 or 32 thermocouple connections at a 20Hz sampling rate.

  • Supports K, J and T-type thermocouples

  • Simple signal configuration using a DBC file

hashtag
Technical Specifications

Technical Data
Description

K-PT

INF2212

Our K-PT module is designed to connect PT100/1000 sensors to a K-Box or K-AN8 voltage measurement device that normally cannot support these sensors. The powered K-PT module enables PT100/1000 sensors to be connected via the D-Sub 9 terminals and will output the signal voltages to an Analogue measurement device.

Calibration and sampling rates can be configured using the freely distributed K-Cal software.

K-PT 100/1000
file-pdf
508KB
KIEPE&PT Flyer.pdf
PDF
arrow-up-right-from-squareOpen
PDF Download

hashtag
Key Features

  • Connects up to 4 RTD sensors to the K-Series K-Box/K-AN8 via the Analogue inputs

  • Simple signal configuration using a DBC file

  • Supplied with configuration software Influx K-Cal for Windows®

  • Refresh rates achievable (4 channels 20Hz)

  • ABS enclosure

hashtag
Technical Specifications

Technical Data
Description

K-Box

INF2201

K-Box Multi-DAQ Modules aid in measuring Thermocouples, Voltages, Currents and PWM. These include our unique power down and WakeOnCAN feature and can be stacked with all of our K-series instrumentation modules.

K-Box transmits the Data periodically on the CAN Bus for accurate sensor measurement.

hashtag
Key Features

Supports logging of timestamped temperature data inside an integrated eMMC (8GB)
  • Supplied with configuration software Influx K-Cal for Windows® and configurable via a DBC file

  • Device drivers available for Windows® applications (32/64-bit)

  • Configuration and programming via CAN or USB interface

  • WakeOnCAN enables K-TC 2.0 modules to power up and power down in deep sleep mode

  • Measurement accuracy: ±1 degree C, Measurement resolution: 0.001 degree C

  • Instrumentation data time synchronised with recorded vehicle network data via CAN

  • Galvanic isolation (USB, CAN, Power, and TC Boards)

  • Free TC Logger software

  • 24mA at 12V / 25mA at 12V / 30mA at 12V

    Configuration

    Via CAN bus with K-Cal for calibration. Via USB with TC Logger SW for logging configurations stored in the device

    Interfaces (Isolated)

    CAN bus (max 1000 kbps) and USB 2.0

    Storage

    8 GB eMMc

    PC Interfaces

    USB2.0 Type B (isolated)

    Enclosure

    Dimension (LxHxW): 115x56(K-TC8) / 79(K-TC16) / 149(K-TC32) x 105mm

    Weight 450g(K-TC8), 570g(K-TC16), 900g(K-TC32)

    IP 40 IP 65 (With all thermocouples plugged in)

    ABS/Aluminum Allow* (depending upon the stock availability)

    Environmental

    -40°C to +85°C

    Humidity max 90%

    Thermocouple Inputs

    K, J, T-type

    Accuracy ± 1°C

    Measurement: -200 °C to 1250 °C

    Connection type

    Thermocouples: mini K, J ,T-Type (galvanically connected)

    Thermocouple Inputs

    Number of channels

    K-TC8: 8 channels, K-TC16: 16 channels, K-TC32: 32 channels (group of 8 isolated/each galvanically connected)

    Channel Input Types

    K, J, T

    Measurement Range

    (-)200°C to (+)1200°C

    Max Sampling Rate

    20 Hz per channel

    Max applied voltage

    ± 3.3 V

    Peak Galvanic Isolation Voltage (from all other modules and power supplies)

    Three-wire CAN Bus

    780 V

    Four-wire USB Bus

    840 V

    Two-wire power module

    560V

    Power supply

    4.5 to 31V DC (isolated)

    Power consumption

    K-TC8 / K-TC16 / K-TC32

    Normal operation

    120mA at 12V / 140mA at 12V / 200mA at 12V

    Detailed Documentation

    Power down standby mode

    Standard tables for different types of ALPHA

    Internal resolution

    18 Bit

    Internal sampling rate per channel.

    6.25kHz

    Measurement data rate per channel.

    1, 2, 5, 10, 20 Hz

    HW HW input filter

    Input filter common mode; Output filter on the amplifier; Differential-Mode Corner Frequency 7.6Hz, Common-Mode Corner Frequency: 159Hz

    SW input filter

    A digital filter in the ADC module is automatically adjusted to the sampling rate. With the current setting (sampling at 6.25kHz), the filter has a frequency of 3kHz

    Broken sensor detection

    Yes

    Measurement current

    The current changes, depending on the resistance of the sensor, within the range: 212-224µA

    Gain error at 25degC

    ± 0.1% of measured value

    Offset and scaling error

    ±1K

    Gain drift

    ±10ppm/K of measured value

    Zero drift

    ±5 mK/K

    CAN channel Isolation

    1000VDC minimum

    CAN power supply Isolation

    CAN and Power are galvanically connected

    CAN interface

    CAN 2.0B, up to 1Mbit/s

    Configuration

    Configuration with K-Box Cal application by company protocol

    Power supply

    4.5V to 36V DC.

    Power consumption

    Typ. 1.9W

    Designation housing

    ABS

    Protection class

    IP65

    Weight

    450g

    Dimensions

    115x46x105mm

    CAN power supply

    Two 9 pin D-type connectors with duplicate signals

    Signal inputs

    Two channels are integrated into a 9 pin D-type connector

    Operation temperature range

    -40degC to +85degC

    Measurement inputs

    4

    Type of measured sensors

    PT100/1000

    Measurement range

    -200degC to +850degC

    Linearization

    Software switchable voltage input ranges from ±80V to ±10V

  • Up to 8 thermocouple connections at up to 10 Hz sampling rate

  • 8 Analog inputs with variable input sampling rates (8 channels at 1kHz, 4 channels at 2kHz and 2 Channels at 10kHz)

  • Very high accuracy-Analog ±0.0015%,Thermocouples ±1°C

  • PWM: 3 inputs frequency measurements, counters or pulse measurements

  • Outputs: 4 Relay outputs (optional)

  • Regulated +5V and +24V output power supply for external sensors

  • Supplied with configuration software, Influx K-Cal for Windows® and configurable via a DBC file

  • Instrumentation data time synchronised with recorded vehicle network data via CAN

  • Galvanic isolation between modules (enclosure, power, CAN BUS and Analog input module and thermocouple input module)

  • Measurement accuracy: ±1° C

  • Measurement resolution: 0.1°C

  • Analog channel over-voltage protection ±150 Volt

  • hashtag
    Advantages

    • Combined Voltage, Thermocouple and PWM/Digital measurements

    • Cold junction compensation for accurate thermocouple measurement

    • High input impedance on Analog inputs

    • WakeOnCAN and power down deep sleep mode

    hashtag
    Technical Specification

    Technical Data
    Description

    Power supply

    6V to 36V DC.

    Interfaces

    CAN Bus

    PC interfaces

    None

    Detailed Documentation

    file-pdf
    541KB
    KBox Flyer.pdf
    PDF
    arrow-up-right-from-squareOpen
    PDF Download

    K-AN8

    INF2210

    K-AN8 Analog Modules- for combined Voltages, Current and PWM Signals Accurate analog and digital sensor measurement data for CAN applications. A stackable, Easy, and cost-effective solution to measuring Analog and digital/P.W.M. sensors together in one module.

    The K-AN8 includes our unique power down and WakeOnCAN feature for quick installation on long-term unattended fleet test vehicles. Accurate sensor measurement data is transmitted periodically on the CAN Bus, enabling multiple K-Series modules to be connected together.

    The K-AN8 CAN Bus settings, calibration, and sampling rates are all configurable and stored even when not powered.

    file-pdf
    506KB
    KAN8 Flyer.pdf
    PDF
    arrow-up-right-from-squareOpen
    PDF Download

    hashtag
    Key Features

    • 8 analog inputs with variable input sampling rates

    • (8 channels at 1k Hz, 4 channels at 2kHz, 2 channels at 10k Hz and 5kHz)

    • PWM: 3 inputs frequency measurements, counters or pulse measurements

    hashtag
    Advantages

    • Combined Voltage, P.W.M./Digital measurements

    • Software switchable voltage input ranges from ±80V to ±10V

    • Very high accuracy- Analog ±0.0015%

    hashtag
    Technical Specification

    Technical Data
    Description

    ReXgen 2

    INF2110.01/INF2110.02- Hardware Versions- 8/16 Gb- Current Range (Non-modular)

    The Influx ReXgen 2 is a small, robust, powerful CAN bus data recorder. Targeted at applications that require a CAN 2.0, CAN FD and LIN flight data recorder. Supplied with ReXdesk, freely distributable software for the ReXgen 2. used for logger configuration and file exporter.

    hashtag
    Key Features

    K-IEPE

    INF2213

    Our K-IEPE module is designed to connect IEPE sensors to a K-Box or K-AN8 voltage measurement device that normally cannot support IEPE sensors.

    The powered K-IEPE module simply enables IEPE sensors to be connected via the BNC terminals and will output the signal voltages to the analog measurement device.

    Calibration and sampling rates can be configured using the freely distributed K-Cal software.

    hashtag

    Enclosure

    Dimension (L115xH79xW105) / Weight 450g / IP65 / ABS

    Environmental

    -40°C to +85°C Humidity max 90%

    Output voltages

    5V and 24V (Max current drawn 80 mA combined)

    Analog Inputs

    Number of channels

    8 Bipolar differential inputs

    Accuracy

    ±0.0015%

    Software switchable range

    ±80V, ±40V, ±20V, ±10V

    Resolution (ADC)

    16 Bit

    Max Sampling Rate

    1 KHz (all 8 channels), 2 KHz (4Channels), 10 KHz (2 Channels)

    Input impedance

    > 4 M Ohm

    Max input voltage

    ±75 Analog Ground, ±34 V Analog inputs

    Thermocouple Inputs

    Number of channels

    8 J/K/T-type inputs

    Accuracy

    ±1°C accuracy

    Measurement Range

    Measurement: -200 °C to 1250 °C

    Max Sampling Rate

    10 Hz (all 8 channels)

    Maximum input voltage

    ±3.3 V

    Digital Input / Output

    Number of channels

    Ă—4 unipolar single-ended hardware configured as inputs or outputs

    Input switching thresholds

    Low < 1.5V

    High > 2.0V (up to 12V)

    Input leakage current

    < 10nA

    Output states

    (Optional) Open collector - 510 Ohm

    Output drive capability (OK):

    Collector-emitter voltage

    45V max

    Collector current (DC)

    10mA max

    Saturation voltage (OK on)

    < 0.15V

    Equivalent on-resistance

    < 510Ohm

    Leakage current at OK off

    < 5uA

    Min-max applied voltage

    Digital input -8V to +12V; Digital output 0V to +40V power supply, which limits the current to 10mA

    PWM

    3 digital input frequency measurements up to 100kHz or pulse measurements. (min 100 Nano sec) (between pulses 10 microseconds)

    Outputs: 4 Relay outputs. (Optional)
  • Regulated +5V and +24V output power supply for external sensors

  • Supplied with configuration software, Influx K-Cal for Windows® and configurable via a DBC file

  • Instrumentation data time synchronised with recorded vehicle network data via CAN

  • Galvanic isolation between modules (enclosure, power, CAN BUS and analog input module)

  • Analog channel over-voltage protection +150 Volt

  • Stackable ABS enclosure

  • High input impedance on Analog inputs
  • WakeOnCAN and power down deep sleep mode

  • Dimension (L115xH56xW105)

    Weight 450g

    IP65

    ABS

    Environmental

    -40°C to +85°C Humidity max 90%

    Output Voltages

    5V and 24V (Max current drawn 80 mA combined)

    Analog Inputs

    Number of channels

    8 Bipolar differential inputs

    Accuracy

    ±0.0015%

    Software switchable Range

    ±80V, ±40V, ±20V, ±10V

    Resolution (ADC)

    16 Bit

    Max Sampling Rate

    1 KHz (all 8 channels), 2 KHz (4Channels), 10 KHz (2 Channels)

    Input Impedance

    > 4 MOhm

    Min-Max Applied Voltage

    ±75 V vs Analog Ground, ±150 V between Analog inputs

    Digital Input / Output

    Number of channels

    Ă—4 unipolar single-end hardware configured as input or output.

    Input switching thresholds

    Low < 1.5V

    High > 2.0V (up to 12V)

    Input leakage current

    < 10nA

    Output states

    (Optional) Open collector & 510Ohm

    Output drive capability

    45V max

    Collector current (DC)

    10mA max

    Saturation voltage (OK on)

    < 0.15V

    Equivalent on-resistance

    < 510Ohm

    Leakage current at OK off

    < 5uA

    Min-Max applied voltage

    Digital input -8V to +12V; Digital output 0V to +40V power supply, which limits the current to 10mA

    PWM

    3 digital inputs frequency measurements up to 100KHz or pulse measurements. (min 100 Nanoseconds, min time between pulses 10 microseconds)

    Power supply

    6 to 36V DC.

    Interfaces

    CAN Bus

    PC interfaces

    None

    Enclosure

    2x CAN 2.0/CAN FD buses, 1x LIN bus
  • 2x Digital Input channels, 2x Analog Input channels

  • Powerful graphic interface application tool

  • Supported Data formats -ASAM MDF4 MATLAB (.mat), CSV, ASC, BLF & TRC

  • Up to 16GByte eMMC storage

  • Micro USB 2.0 -High-speed connection to logger

  • Functions as an interface device and supports J2534 (Pass-thru)

  • Supports CAN monitoring RAW CAN signals, SAE J1939

  • Very low power consumption in sleep mode and WakeOnCAN, WakeOnAlarm & WakeOnSignal

  • CAN frame error detection ASAM MDF(*.mf4 format) -international standard data format

  • LEDs support status indication

  • IP65 enclosure protection

  • Plug and play, easily stackable and installable

  • hashtag
    Technical Specifications

    Functions

    ReXgen 2

    CAN Interfaces

    2 x CAN/CAN FD

    ISO 11898-1: Compliant with CAN (up to 1 Mbit/s)

    ISO & Bosch CAN FD (up to 8 Mbit/s)

    Conforms to CAN protocol version 2.0 - part A, B

    Max 20000 mps

    Meets the requirements of ISO 11898-2:2016 & ISO 11898-5:2007 physical layer standards

    CAN/CAN FD Functions

    Supports custom baud rates

    CAN/CAN FD Bit timing selection

    SAE J1939 support (Source Address, Destination Address & PGN Filters)

    Silent Mode Configurable

    CAN DBC Support

    CAN frame error detection

    LIN Interface

    1 x LIN (up to 20 K Baud with LIN-Compatible Output Driver)

    hashtag
    Electrical Data

    BUS & Signals

    Operating Voltage

    Power supply - OBD

    +5V to +27V

    Power supply - USB

    +4.5 to +5.5V

    CAN FD

    +2 to +3V

    Function
    Description

    Transceiver Protection(CAN)

    Bus fault protection: ±58 V

    Thermal-shutdown protection (TSD)

    Common mode input voltage: ± 12V

    TXD dominant timeout (prevents network blocking in the event of a failure)

    Under-voltage protection

    Transceiver Protection (LIN)

    ±8 kV HBM ESD, ±2 kV CDM, ± bus Fault

    TXD dominant timeout (to prevent the LIN node from permanently driving the LIN Bus dominant)

    Power Voltage

    5V for external sensor (current consumed should be less than 10mAmp)

    *Automotive customized connector is also available

    file-pdf
    1MB
    Rexgen 2 & IMU flyer_V1.5.pdf
    PDF
    arrow-up-right-from-squareOpen
    PDF Download
    Key Features
    • Connects to the K-Series K-Box/K-AN8 via the Analog inputs

    • Refresh rates achievable (4 channels 1kHz)

    • ABS enclosure

    hashtag
    Advantages

    • Wide frequency range

    • Linear amplitude characteristics in a wide dynamic range

    • Ability to operate in severe ambient conditions (temperature, humidity, radiation and magnetic fields)

    • High mechanical reliability and durability at the expense of moving parts in the sensor

    • High vibration and shock resistance

    • No need for other power supplies for sensors

    • Compact structure and a large ratio of sensitivity to mass

    hashtag
    Technical Specifications

    Technical Data
    Description

    Measurement inputs

    4

    Internal resolution

    18 bit

    Internal sampling rate per ch.

    6.25kHz

    file-pdf
    509KB
    KIEPE&PT Flyer.pdf
    PDF
    arrow-up-right-from-squareOpen
    PDF Download
    K-IEPE

    Measurement data rate per ch.

    4 channels: 1kHz. CAN bus: 1Mbit/s

    SW input filter

    A digital filter in the ADC module is automatically adjusted to the sampling rate

    High pass filter

    13.8Hz

    Bandwidth

    21.8Hz

    Operational safety

    -0.7V to +24V permanent, additional

    Device safety

    -0.7V to +24V permanent, additional ESD protection

    Input impedance

    >10K

    Broken sensor detection

    Yes

    Typical SNR @ 30kHz Band Width

    Sampling @6.25Hz: 102dB

    Linearity

    ADC ±0.75 LSB

    Current source

    5.1mA ± 2%

    Voltage

    24V

    Output power

    Maximum total (for 4 channel) current: 60mA

    Channel/ power supply Isolation

    1000 VDC minimum

    Sensor excitation/ power supply Isolation

    1000 VDC minimum

    CAN channel Isolation

    1000 VDC minimum

    CAN power supply Isolation

    CAN and power are galvanically connected

    Configuration

    Configuration with K-Box Cal application by company protocol

    Power supply

    4.5V to 36V DC.

    Power consumption

    Typ. 2.6W

    Housing

    ABS

    Dimensions/ Weight/ Protection Class

    D: (128x46x105mm); W: 450g; PC: IP65

    CAN/ Power supply

    Two 9-pin D-Type connections with duplicate signals

    Signal Inputs

    BNC Connector

    Operating temperature range

    -40degC to +85degC

    Inputs

    2 x Digital and 2 x Analog (max sampling rate-1KHz)

    PC Interfaces

    Rugged Micro USB 2.0

    (Datalogger mode and J2534)

    Data Storage Capability

    8 or 16 GB Inbuilt eMMC storage (uses FIFO logic once the eMMC is full)

    Supported Protocols

    CAN Monitoring (RAW CAN signals, SAE J1939 support)

    LEDs

    2

    Triggering

    Trigger on CAN ID, CAN Signal, and Digital Input.

    Trigger on DM1 counter.

    Data Storage Format

    Log files accessible via ReXdesk Software

    File Format Supported

    ASAM MDF (.mf4), Peak TRC, CSV, MATLAB, ASC, BLF

    Data Logger Configuration

    Supplied with Influx ReXdesk configuration software, XML based

    Analog Input

    Number of channels

    2 x Bipolar single-ended inputs

    Range

    ± 10 V

    Resolution (ADC)

    12 Bit

    Max sampling rate

    1 kHz

    Input Impedance

    > 50 K Ohms

    Safe Applied Voltage

    ± 28 V

    Digital Input

    Number of channels

    2 x Unipolar single-ended inputs

    Input Switching Thresholds

    Low < 0.8 V, High > 2.5 V (up to 28V)

    Safe Applied Voltage

    ± 28 V

    LIN

    0 to +24V

    Digital Input

    0 to +28V

    Analog input

    ± 10V

    Enclosure

    PC+ ABS

    IP Rating

    IP65

    Dimension

    L - 100 mm, W - 73.5 mm, H – 27.4 mm

    Weight

    164 gms

    Mounting Holes

    4 mounting holes and screws

    Stackable

    Yes

    Environmental Tolerance

    Working temperature -40degC to +85degC; Humidity max 90%

    Silent Mode

    Listen only mode available (configurable Silent mode)

    Power Saving

    Wake Up On CAN, Wake up on Movement, Power Down Mode, Sleep Modes

    Power Safe

    100% power safe data logging - no file corruption when disconnected or in sleep mode

    Protection

    Reverse voltage protection on CAN-bus supply

    Power Consumption

    Normal Operation: <75 mA at 12 V

    Normal sleep <17mA

    Deep Sleep <2 mA

    ReXgen Air

    INF2116.NN - Hardware Configurable (Up to 32 GB)

    ReXgen Air is a compact, robust, accurate and cost-effective solution designed to become part of your fleet during production.

    This is a progressive system that works on LTE CAT1. A data logger with onboard processing and telematics capabilities connects machines to the cloud or stores data locally.

    Allows the encryption of data logs with the Secure Hash Algorithm (SHA).

    An open platform that can be supported by any third-party tools and integrated into any data system. It is supplied with a free, powerful graphic interface application tool.

    ReXgen Air allows you to build your system to maintain your data.

    hashtag
    Key Features

    • Up to 4 CAN/CAN FD buses

    • x1 LIN bus

    • x2 Analog Inputs, x2 Digital inputs & x1 Power Stage Relay Driver (Optional)

    hashtag
    Technical Specifications

    Functions
    ReXgen Air
    circle-exclamation

    hashtag
    Attention:

    • To set up a USB via the Molex connector, please specify this requirement when ordering, or the device must be sent back to Influx (as this requires some hardware modification).

    *CEP - circular error probable

    *FTPS- PROT P (Data channel encryption not supported.

    * The region and category of the modem should be specified when ordering.

    * Works with AT&T and T-Mobile in the USA.

    hashtag
    Electrical Data

    Function
    Description

    Integrated 18Hz GNSS (u-Blox) and IMU (6 axis)
  • Encrypts data logs using Advanced Encryption Standard (AES)

  • Open API or XML Schema provided

  • Live CAN/CAN FD trace Monitoring

  • Enables Locking of the device using RSA data security

  • Micro USB 2.0 for data transfer and configuration

  • CAT -1 connectivity

  • Secure Data transfer using FTPs and Amazon S3

  • Supported Data formats -ASAM MDF4 MATLAB (.mat), CSV, ASC, BLF & TRC

  • Various sleep modes with low power consumption

  • x4 configurable LEDs

  • CAN/J1939 filters

  • Easily stackable and installable

  • Automotive grade Molex Mini50 connection system

  • Support for logging CAN error frames (bit-stuffing, form, CRC, bit, acknowledgement)

    Retransmission

    Configurable retransmission of frames that have lost arbitration or been disturbed by errors

    Prescaling

    Pre-scale CAN frames to record e.g., by time (per X ms) or by data (e.g., if byte X or Y changes)

    Transmit

    Transmit lists of CAN frames per channel (periodic) - e.g., for OBD2 requests- Capability to link multiple CAN messages

    LIN Interface

    1 x LIN (Master & Slave mode)

    Compliant with LIN Bus Specifications 1.3, 2.0 and 2.1 and are compliant to SAE J2602

    LIN channel can be configured as a LIN subscriber/publisher with support for LIN data transmission

    Support for custom frame lengths

    Parallel CAN/LIN

    Record data from up to upto 4 x CAN channels + 1 x LIN channels, simultaneously

    Connector

    Molex Mini50 Dual Row 24 Pin connector (enables the device to be easily and robustly installed in production machines)

    LTE

    CAT 1 (see uBlox Lara R2 Series)/Quectel CAT 4

    Inputs

    2 x Digital and 2 x Analog

    Bit-Rate Auto-Detect

    Bit rate can be auto-detected or set manually

    Instrumentation Supply

    5 Volts (Ensure that current draw is not more than 100mA)

    Real-Time Clock

    Yes - CAN frames are date & timestamped with 10 microsecond resolution (battery backup)

    The RTC can be configured to match local time zones (default: UTC)

    The RTC can be auto-synced via 3G/4G LTE Timestamp or a CAN message (e.g., from the internal GNSS timestamp)

    File Split

    Configurable log file split size (by size: 10-500 MB and/or by time period)

    Unique Device ID

    Each device has a globally unique ID ensuring unique log file naming

    Signed Firmware

    Firmware updates are digitally signed to verify that they are from a trusted source

    Cyclic Logging

    Enabled by default

    Positioning Sensors

    GNSS Module

    M8U-30 Hz (supports dead reckoning) / M8Q-18Hz (does not support dead reckoning) Supports 4 position systems with highly accurate positioning.

    GNSS Receiver Type

    72-channel, GNSS L1C/A, SBAS L1C/A, QZSS L1C/A, QZSS L1-SAIF, GLONASS L1OF, BeiDou B1I , Galileo E1B/C

    Position Accuracy

    2.0 m CEP*

    Sensitivity

    Tracking/Navigation: 167 dBm | Cold starts: 148 dBm

    Acquisition

    Cold starts: 26s

    Reacquisition: 2 s

    Antenna

    External FAKRA antenna (3m included) Code C

    Accuracy

    Velocity: 0.05m/s

    Heading: 0.3 degrees

    Others

    IMU

    6D IMU

    Accelerometer

    ±2/±4/±8/±16 g full scale

    Gyroscope

    ±125/±250/±500/±1000/±2000 dps full scale

    PC Interfaces

    Micro USB Type AB 2.0 interface (Standard version)

    USB interface via the Molex Mini50 connector (Optional)

    Data Storage Capability

    Up to 32 GB eMMC storage (non-removable) (uses FIFO logic once the eMMC is full)

    Supported Protocols

    CAN Monitoring (RAW CAN signals, SAE J1939 support, FMS, CANopen, NMEA 2000, OBD2, CAN FD, UDS)

    LEDs

    4

    Triggering

    Trigger on CAN ID, CAN Signal, Digital Input.

    Trigger on DM1 counter.

    Filters

    200* regular/extended ID filters per channel (range, acceptance)

    File Format Supported

    RXD, RXE, ASAM MDF (.mf4), CSV, MATLAB, ASC, BLF, TRC

    Warranty

    12 months from the date of invoice.

    Support

    Yes, during the warranty period

    Origin

    UK

    Protocol

    FTP/FTPS/HTTP/HTTPS

    Data Transfer Protocol

    FTPS and Amazon S3

    Security Functions

    Encryption of data logs, Locking of device.

    Encryption Standard

    RSA* (for locking device) and AES* (for log data)/GDPR/CCPA/SHA

    Data Logger Configuration

    Supplied with Influx ReXdesk configuration software, API, CLI

    Software

    Supplied with Influx ReXdesk configuration software, API, CLI

    Free open Source ReXcloud platform for managing devices and data via your browser

    Free open source asammdf software & API, DBC converting & plotting MF4 data

    Free data convertors, CLI based/ .net DLL for converting RXD into RXE, ASAM MDF (.mf4), CSV, MATLAB, ASC, BLF, TRC

    Free open-source AWS Lambda, Example Application for data processing/ Supports AWS time stream/DB to integrate with third party dashboard

    Firmware

    Supports free firmware updates for adding features

    Analog Input

    Number of channels

    2 x Bipolar single-ended inputs

    Range

    ± 10 V

    Resolution (ADC)

    12 Bit

    Max sampling rate

    1 kHz

    Input Impedance

    > 50 K Ohms

    Safe Applied Voltage

    ±28 V

    Digital Input

    Number of channels

    2 x Unipolar single-ended inputs

    Input Switching Thresholds

    Low < 0.8 V, High > 2.5 V (up to 28V)

    Safe Applied Voltag

    28 V

  • ReXgen Air is an IP50 device (please ensure it is covered when mounting it in locations that may have water ingress).

  • Coverage

    Global * Available on request

    Antenna

    External FAKRA antenna (3m included) Code D

    Server Interface

    FTP/FTPS/S3

    SIM Slot

    External nano sim slot/ esim available on request

    Over-The-Air (OTA)

    Configuration & firmware over-the-air (COTA/FOTA). Configurable sync rate. Optionally disable

    Heartbeat

    Yes

    Data Upload State

    Yes

    CAN Heartbeat

    Optionally transmit heartbeat CAN frame with device info, device status, storage used RTC time & config-details

    Snapshot

    Decode and send CAN signals periodically to the server

    HTTPS

    Data & over-the-air updates can be sent via HTTPS (TLS 1.2) for secure transfer

    User Policies

    Fully customize access rights across devices and end users through S3 policies * (when using AWS upload)

    Credential Encryption

    S3 server credentials can be encrypted in the config on the device

    LIN

    0 to +24V

    Digital Input

    0 to +28V

    Analog input

    ± 10V

    PC+ ABS

    IP Rating

    IP50 (Please ensure to cover the device when mounting it in locations that may have water ingress)

    Dimension

    L - 100 mm, W - 65 mm, H – 30 mm

    Weight

    112 Grams

    Mounting Holes

    4 mounting holes and screws

    Stackable

    Yes

    Environmental Tolerance

    Working temperature -40degC to +85degC; Humidity max 90%

    Silent Mode

    Listen only mode available (configurable Silent mode)

    Power Saving

    Wake Up On CAN, Wake up on Movement, Power Down Mode, Sleep Modes

    Power Safe

    100% power safe data logging - no file corruption when disconnected or in sleep mode

    Power Consumption

    Normal (usage without Cloud) <120mA at 12V

    Normal (usage with Cloud) <300mA

    Normal sleep <21mA

    Deep sleep <10mA

    Protection

    Reverse voltage protection on CAN-bus supply

    CAN Interfaces

    Up to 4 x CAN/CAN FD

    ISO 11898-1: Compliant with CAN (up to 1 Mbit/s)

    ISO & Bosch CAN FD (up to 8 Mbit/s)

    Conforms to CAN protocol version 2.0 - part A, B

    Up to 20000 mps

    Meets the requirements of ISO 11898-2:2016 & ISO 11898-5:2007 physical layer standards

    CAN/CAN FD Functions

    CAN/CAN FD Bit timing selection

    SAE J1939 support (Source Address, Destination Address & PGN Filters)

    Silent Mode Configurable Periodic CAN Transmission CAN DBC Support

    CAN frame error detection

    Identifiers

    Compliant with CAN specifications 2.0A (11-Bit ID) and 2.0B (29-Bit ID)

    Integrated GPRS

    LTE modem

    Category

    Professional-grade uBlox Lara R2 Series LTE Cat1/ Quectel EC 20/25 CAT 4*

    LTE CAT1 Bands

    LTE FDD Bands: 1(2100 MHz) ,2(1500 MHz), 3(1800 MHz),4(1700 MHz), 7(2600 MHz), 8(900 MHz), 12(700 MHz), 13(700 MHz), 19(850 MHz), 20(800 MHz), 28(700 MHz)

    Receiver input Sensitivity

    -98dBm to -114dBm: 700MHz to 2100MHz

    BUS & Signals

    Operating Voltage

    Power supply - OBD

    +5V to +27V

    Power supply - USB

    +4.5 to +5.5V

    CAN/CAN FD

    +2 to +3V

    Transceiver Protection (CAN)

    Bus fault protection: ±58 V

    Thermal-shutdown protection (TSD)

    Common mode input voltage: ± 12V

    TXD dominant timeout (prevents network blocking in the event of a failure)

    Under-voltage protection

    Transceiver Protection (LIN)

    ±8 kV HBM ESD, ±2 kV CDM, ± bus Fault

    TXD dominant timeout (to prevent the LIN node from permanently driving the LIN Bus dominant)

    Power Voltage

    5V for external sensor (current consumed should be less than 100mAmp)

    file-pdf
    1MB
    ReXgen Air_V1.2.pdf
    PDF
    arrow-up-right-from-squareOpen
    PDF Download
    ReXgen Air

    CAN Error Frames

    Enclosure

    ReXgen 2 IMU

    INF2112.02/INF2112.03- Hardware Versions- 16/32GB GNSS- Current Range (Non-modular)

    The ReXgen 2 IMU is the upgraded version of ReXgen 2, which also supports GNSS, Gyro and Accelerometer. A device that can also record vibration and position information in very harsh environments, even if no GPS signal is available.

    Logs data continuously for hours from a CAN bus and simultaneously saves it to the embedded SD memory card. Supplied with ReXdesk, freely distributable software for the ReXgen 2. used for logger configuration and file exporter.

    file-pdf
    1MB
    Rexgen 2 & IMU flyer_V1.5.pdf
    PDF
    arrow-up-right-from-squareOpen
    PDF Download

    hashtag
    Key Features

    • 2x CAN 2.0/CAN FD buses, 1x LIN buses

    • 2x Digital Input channels, 2x Analog Input channels

    • Powerful graphic interface application tool

    *Automotive customized connector is also available

    hashtag
    Technical Specifications

    hashtag
    Electrical Data

    Function

    * CEP - circular error probable

    *Automotive customized connector is also available

    Supported Data formats -ASAM MDF4 MATLAB (.mat), CSV, ASC, BLF & TRC
  • Up to 32GByte eMMC storage

  • Micro USB 2.0 -Higher speed connection to the logger

  • Functions as an interface device and supports J2534 (Pass-thru)

  • Supports CAN trace monitoring RAW CAN signals, SAE J1939

  • Very low power consumption in sleep mode and WakeOnCAN, WakeOnAlarm & WakeOnSignal

  • CAN frame error detection ASAM MDF(*.mf4 format) -international standard data format

  • LEDs support status indication

  • IP65 easily stackable and installable enclosure

  • Up to 18Hz GNSS rate/u-Blox -Supports 4 position systems for highly accurate positioning.

  • Gyro and Accelerometer system

  • Inputs

    2 x Digital and 2 x Analog (max sampling rate-1KHz)

    Positioning & IMU Sensors

    GNSS

    Up to 18 Hz rate

    GNSS Receiver Type

    72-channel, GNSS L1C/A, SBAS L1C/A, QZSS L1C/A, QZSS L1-SAIF, GLONASS L1OF, BeiDou B1I , Galileo E1B/C

    Position Accuracy

    2.0 m CEP*

    Acquisition

    Cold starts: 26s

    Reacquisition: 2 s

    Antenna

    External

    Accuracy

    Velocity: 0.05m/s

    Heading: 0.3 degrees

    Altitude: not specified

    Accelerometer

    ±2/±4/±8/±16 g full scale

    (max sampling rate-1KHz)

    Gyroscope

    ±125/±250/±500/±1000/±2000 dps full scale

    (max sampling rate-1KHz)

    PC Interfaces

    Rugged Micro USB 2.0

    (Datalogger mode and J2534

    Data Storage Capability

    16 or 32 GB Inbuilt eMMC storage (uses FIFO logic once the eMMC is full)

    Supported Protocols

    CAN Monitoring (RAW CAN signals, SAE J1939 support)

    LEDs

    2

    Triggering

    Trigger on CAN ID, CAN Signal, and Digital Input.

    Trigger on DM1 counte

    Data Storage Format

    Log files accessible via ReXdesk Software

    File Format Supported

    ASAM MDF (.mf4), Peak TRC, CSV, MATLAB, ASC, BLF

    Data Logger Configuration

    Supplied with Influx ReXdesk configuration software, XML based

    Analog Input

    Number of channels

    2 x Bipolar single-ended inputs

    Range

    ± 10 V

    Resolution (ADC)

    12 Bit

    Max sampling rate

    1 kHz

    Input Impedance

    > 50 K Ohms

    Safe Applied Voltage

    ± 28 V

    Digital Input

    Number of channels

    2 x Unipolar single-ended inputs

    Input Switching Thresholds

    Low < 0.8 V, High > 2.5 V (up to 28V)

    Safe Applied Voltage

    ± 28 V

    LIN

    0 to +24V

    Digital Input

    0 to +28V

    Analog input

    ± 10V

    PC+ ABS

    IP Rating

    IP65

    Dimension

    L - 100 mm, W - 73.5 mm, H – 27.4 mm

    Weight

    164 gms

    Mounting Holes

    4 mounting holes and screws

    Stackable

    Yes

    Environmental Tolerance

    Working temperature -40degC to +85degC; Humidity max 90%

    Silent Mode

    Listen only mode available (configurable Silent mode)

    Power Saving

    Wake Up On CAN, Wake up on Movement, Power Down Mode, Sleep Modes

    Power Safe

    100% power safe data logging - no file corruption when disconnected or in sleep mode

    Protection

    Reverse voltage protection on CAN-bus supply

    Power Consumption

    Normal Operation: <80 mA at 12 V

    Normal sleep <25mA

    Deep Sleep <2 mA

    Functions

    ReXgen 2 IMU

    CAN Interfaces

    2 x CAN/CAN FD

    ISO 11898-1: Compliant with CAN (up to 1 Mbit/s)

    ISO & Bosch CAN FD (up to 8 Mbit/s)

    Conforms to CAN protocol version 2.0 - part A, B

    Max 20000 mps

    Meets the requirements of ISO 11898-2:2016 & ISO 11898-5:2007 physical layer standards

    CAN/CAN FD Functions

    Supports custom baud rates

    CAN/CAN FD Bit timing selection

    SAE J1939 support (Source Address, Destination Address & PGN Filters)

    Silent Mode Configurable

    CAN DBC Support

    CAN frame error detection

    LIN Interface

    1 x LIN (up to 20 K Baud with LIN-Compatible Output Driver)

    BUS & Signals

    Operating Voltage

    Power supply - OBD

    +5V to +27V

    Power supply - USB

    +4.5 to +5.5V

    CAN FD

    +2 to +3V

    Transceiver Protection(CAN)

    Bus fault protection: ±58 V

    Thermal-shutdown protection (TSD)

    Common mode input voltage: ± 12V

    TXD dominant timeout (prevents network blocking in the event of a failure)

    Under-voltage protection

    Transceiver Protection (LIN)

    ±8 kV HBM ESD, ±2 kV CDM, ± bus Fault

    TXD dominant timeout (to prevent the LIN node from permanently driving the LIN Bus dominant)

    Power Voltage

    5V for external sensor (current consumed should be less than 10mAmp)

    Enclosure