Key Features

  • 2x CAN 2.0/CAN FD buses, 1x LIN bus

  • 2x Digital Input channels, 2x Analog Input channels

  • Powerful graphic interface application tool

  • Supported Data formats -ASAM MDF4 MATLAB (.mat), CSV, ASC, BLF & TRC

  • Up to 16GByte eMMC storage

  • Micro USB 2.0 -High-speed connection to logger

  • Functions as an interface device and supports J2534 (Pass-thru)

  • Supports CAN monitoring RAW CAN signals, SAE J1939

  • Very low power consumption in sleep mode and WakeOnCAN, WakeOnAlarm & WakeOnSignal

  • CAN frame error detection ASAM MDF(*.mf4 format) -international standard data format

  • LEDs support status indication

  • IP65 enclosure protection

  • Plug and play, easily stackable and installable

Technical Specifications

Functions

ReXgen 2

CAN Interfaces

2 x CAN/CAN FD

ISO 11898-1: Compliant with CAN (up to 1 Mbit/s)

ISO & Bosch CAN FD (up to 8 Mbit/s)

Conforms to CAN protocol version 2.0 - part A, B

Max 20000 mps

Meets the requirements of ISO 11898-2:2016 & ISO 11898-5:2007 physical layer standards

CAN/CAN FD Functions

Supports custom baud rates

CAN/CAN FD Bit timing selection

SAE J1939 support (Source Address, Destination Address & PGN Filters)

Silent Mode Configurable

CAN DBC Support

CAN frame error detection

LIN Interface

1 x LIN (up to 20 K Baud with LIN-Compatible Output Driver)

Inputs

2 x Digital and 2 x Analog (max sampling rate-1KHz)

PC Interfaces

Rugged Micro USB 2.0

(Datalogger mode and J2534)

Data Storage Capability

8 or 16 GB Inbuilt eMMC storage (uses FIFO logic once the eMMC is full)

Supported Protocols

CAN Monitoring (RAW CAN signals, SAE J1939 support)

LEDs

2

Triggering

Trigger on CAN ID, CAN Signal, and Digital Input.

Trigger on DM1 counter.

Data Storage Format

Log files accessible via ReXdesk Software

File Format Supported

ASAM MDF (.mf4), Peak TRC, CSV, MATLAB, ASC, BLF

Data Logger Configuration

Supplied with Influx ReXdesk configuration software, XML based

Analog Input

Number of channels

2 x Bipolar single-ended inputs

Range

± 10 V

Resolution (ADC)

12 Bit

Max sampling rate

1 kHz

Input Impedance

> 50 K Ohms

Safe Applied Voltage

± 28 V

Digital Input

Number of channels

2 x Unipolar single-ended inputs

Input Switching Thresholds

Low < 0.8 V, High > 2.5 V (up to 28V)

Safe Applied Voltage

± 28 V

Electrical Data

BUS & Signals

Operating Voltage

Power supply - OBD

+5V to +27V

Power supply - USB

+4.5 to +5.5V

CAN FD

+2 to +3V

LIN

0 to +24V

Digital Input

0 to +28V

Analog input

± 10V

Function
Description

Transceiver Protection(CAN)

Bus fault protection: ±58 V

Thermal-shutdown protection (TSD)

Common mode input voltage: ± 12V

TXD dominant timeout (prevents network blocking in the event of a failure)

Under-voltage protection

Transceiver Protection (LIN)

±8 kV HBM ESD, ±2 kV CDM, ± bus Fault

TXD dominant timeout (to prevent the LIN node from permanently driving the LIN Bus dominant)

Power Voltage

5V for external sensor (current consumed should be less than 10mAmp)

Enclosure

PC+ ABS

IP Rating

IP65

Dimension

L - 100 mm, W - 73.5 mm, H – 27.4 mm

Weight

164 gms

Mounting Holes

4 mounting holes and screws

Stackable

Yes

Environmental Tolerance

Working temperature -40degC to +85degC; Humidity max 90%

Silent Mode

Listen only mode available (configurable Silent mode)

Power Saving

Wake Up On CAN, Wake up on Movement, Power Down Mode, Sleep Modes

Power Safe

100% power safe data logging - no file corruption when disconnected or in sleep mode

Protection

Reverse voltage protection on CAN-bus supply

Power Consumption

Normal Operation: <75 mA at 12 V

Normal sleep <17mA

Deep Sleep <2 mA