ReXgen Series

This space contains the technical specification details for all the Influx ReXgen devices.

Technical Specifications

The following space contains the details about the Key features, advantages and technical specificatons of the Influx Products listed below.

ReXgen 1

INF2109.01- Hardware Version- 8 GB

Key Features

  • Supports 1XCAN bus

  • Functions as an interface device and supports J2534 (Pass-thru)

  • Supports live CAN trace monitoring RAW CAN signals, SAE J1939

  • Sleep modes with wake-up on CAN and low power consumption

  • Encrypts data logs using Advanced Encryption Standard (AES)

  • Enables locking of the device using RSA data security

  • Open Libraries for logger management and data Conversion

  • XML-based configuration (Schema provided)

  • Free ReXdesk software that allows the user to export the loaded data to .mf4, .csv, mat, .asc, .blf, .trc and rxd format

  • Supports free firmware updates for adding features

  • Tolerable to harsh environments with an IP65 rating

  • Free powerful graphic interface application tool ReXdesk provided

  • Micro USB 2.0 PC interface

  • CAN error logging

ReXgen 1’s additional features:

  • Efficiently records CAN bus data and advanced message filtering on configurable channels (J1939 and CAN)

  • Supports advanced triggering options and advanced CAN bit timing configuration.

  • The most compact, cost-effective, plug-and-play device operates as a CAN bus interface for real-time USB streaming and has 8GB eMMc storage (uses FIFO logic once the eMMc is full).

  • It supports cyclic logging mode and operates in silent mode.

Technical Specifications

Functions

ReXgen 1

CAN Interfaces

1 x CAN

ISO 11898-1: Compliant with CAN (up to 1 Mbit/s)

Conforms to CAN protocol version 2.0 - part A, B Max 20000 MPs

Meets the requirements of ISO 11898-2:2016 & ISO 11898-5:2007 physical layer standards

PC Interfaces

Rugged Micro USB 2.0 (Datalogger mode and J2534)

Data Storage Capability

8 GB Inbuilt eMMC storage (uses FIFO logic once the eMMC is full)

Supported Protocols

CAN Monitoring (RAW CAN signals, SAE J1939 support)

LEDs

1

Triggering

Trigger on a CAN ID, Trigger on Parameter Value, Trigger on DM1 counter.

Data Storage format

FAT32, Log files accessible via ReXdesk software

File Format Supported

ASAM MDF (.mf4), CSV, MATLAB, ASC, BLF, TRC

Data Logger Configuration

Supplied with Influx ReXdesk configuration software, XML based

BUS & Signals

Operating Voltage

Power supply - OBD

+5V to +27V

Power supply - USB

+4.5 to +5.5V

Transceiver Protection

Bus fault protection: ±58 V Thermal-shutdown protection (TSD)

Under-voltage protection

Enclosure

PC+ ABS

IP Rating

IP65

Dimension

L - 100 mm, W - 73.5 mm, H – 27.4 mm

Weight

164 Grams

Mounting Holes

Four mounting holes and screws

Environmental Tolerance

Working temperature -40degC to +85degC; Humidity max 90%

Power Saving

Wake Up On CAN, Power Down Mode, Sleep Modes,

Power Consumption

Normal Operation: 87 mA at 12 V

Normal Sleep <17mA

Deep Sleep: <2 mA

ReXgen 2 IMU

INF2112.02/INF2112.03- Hardware Versions- 16/32GB GNSS- Current Range (Non-modular)

The ReXgen 2 IMU is the upgraded version of ReXgen 2, which also supports GNSS, Gyro and Accelerometer. A device that can also record vibration and position information in very harsh environments, even if no GPS signal is available.

Logs data continuously for hours from a CAN bus and simultaneously saves it to the embedded SD memory card. Supplied with ReXdesk, freely distributable software for the ReXgen 2. used for logger configuration and file exporter.

Key Features

  • 2x CAN 2.0/CAN FD buses, 1x LIN buses

  • 2x Digital Input channels, 2x Analog Input channels

  • Powerful graphic interface application tool

  • Supported Data formats -ASAM MDF4 MATLAB (.mat), CSV, ASC, BLF & TRC

  • Up to 32GByte eMMC storage

  • Micro USB 2.0 -Higher speed connection to the logger

  • Functions as an interface device and supports J2534 (Pass-thru)

  • Supports CAN trace monitoring RAW CAN signals, SAE J1939

  • Very low power consumption in sleep mode and WakeOnCAN, WakeOnAlarm & WakeOnSignal

  • CAN frame error detection ASAM MDF(*.mf4 format) -international standard data format

  • LEDs support status indication

  • IP65 easily stackable and installable enclosure

  • Up to 18Hz GNSS rate/u-Blox -Supports 4 position systems for highly accurate positioning.

  • Gyro and Accelerometer system

*Automotive customized connector is also available

Technical Specifications

Electrical Data

* CEP - circular error probable

*Automotive customized connector is also available

Comparison List

For ReXgen and Rebel Series data loggers

Rebel Series

Function

Feature
ReXgen 1
ReXgen 2
ReXgen 2 IMU
ReXgen Air
Rebel LT
Rebel CT
Rebel CT CAN FD
Rebel CT Flexray

Functions

ReXgen 2 IMU

CAN Interfaces

2 x CAN/CAN FD

ISO 11898-1: Compliant with CAN (up to 1 Mbit/s)

ISO & Bosch CAN FD (up to 8 Mbit/s)

Conforms to CAN protocol version 2.0 - part A, B

Max 20000 mps

Meets the requirements of ISO 11898-2:2016 & ISO 11898-5:2007 physical layer standards

CAN/CAN FD Functions

Supports custom baud rates

CAN/CAN FD Bit timing selection

SAE J1939 support (Source Address, Destination Address & PGN Filters)

Silent Mode Configurable

CAN DBC Support

CAN frame error detection

LIN Interface

1 x LIN (up to 20 K Baud with LIN-Compatible Output Driver)

Inputs

2 x Digital and 2 x Analog (max sampling rate-1KHz)

Positioning & IMU Sensors

GNSS

Up to 18 Hz rate

GNSS Receiver Type

72-channel, GNSS L1C/A, SBAS L1C/A, QZSS L1C/A, QZSS L1-SAIF, GLONASS L1OF, BeiDou B1I , Galileo E1B/C

Position Accuracy

2.0 m CEP*

Acquisition

Cold starts: 26s

Reacquisition: 2 s

Antenna

External

Accuracy

Velocity: 0.05m/s

Heading: 0.3 degrees

Altitude: not specified

Accelerometer

±2/±4/±8/±16 g full scale

(max sampling rate-1KHz)

Gyroscope

±125/±250/±500/±1000/±2000 dps full scale

(max sampling rate-1KHz)

PC Interfaces

Rugged Micro USB 2.0

(Datalogger mode and J2534

Data Storage Capability

16 or 32 GB Inbuilt eMMC storage (uses FIFO logic once the eMMC is full)

Supported Protocols

CAN Monitoring (RAW CAN signals, SAE J1939 support)

LEDs

2

Triggering

Trigger on CAN ID, CAN Signal, and Digital Input.

Trigger on DM1 counte

Data Storage Format

Log files accessible via ReXdesk Software

File Format Supported

ASAM MDF (.mf4), Peak TRC, CSV, MATLAB, ASC, BLF

Data Logger Configuration

Supplied with Influx ReXdesk configuration software, XML based

Analog Input

Number of channels

2 x Bipolar single-ended inputs

Range

± 10 V

Resolution (ADC)

12 Bit

Max sampling rate

1 kHz

Input Impedance

> 50 K Ohms

Safe Applied Voltage

± 28 V

Digital Input

Number of channels

2 x Unipolar single-ended inputs

Input Switching Thresholds

Low < 0.8 V, High > 2.5 V (up to 28V)

Safe Applied Voltage

± 28 V

BUS & Signals

Operating Voltage

Power supply - OBD

+5V to +27V

Power supply - USB

+4.5 to +5.5V

CAN FD

+2 to +3V

LIN

0 to +24V

Digital Input

0 to +28V

Analog input

± 10V

Transceiver Protection(CAN)

Bus fault protection: ±58 V

Thermal-shutdown protection (TSD)

Common mode input voltage: ± 12V

TXD dominant timeout (prevents network blocking in the event of a failure)

Under-voltage protection

Transceiver Protection (LIN)

±8 kV HBM ESD, ±2 kV CDM, ± bus Fault

TXD dominant timeout (to prevent the LIN node from permanently driving the LIN Bus dominant)

Power Voltage

5V for external sensor (current consumed should be less than 10mAmp)

Enclosure

PC+ ABS

IP Rating

IP65

Dimension

L - 100 mm, W - 73.5 mm, H – 27.4 mm

Weight

164 gms

Mounting Holes

4 mounting holes and screws

Stackable

Yes

Environmental Tolerance

Working temperature -40degC to +85degC; Humidity max 90%

Silent Mode

Listen only mode available (configurable Silent mode)

Power Saving

Wake Up On CAN, Wake up on Movement, Power Down Mode, Sleep Modes

Power Safe

100% power safe data logging - no file corruption when disconnected or in sleep mode

Protection

Reverse voltage protection on CAN-bus supply

Power Consumption

Normal Operation: <80 mA at 12 V

Normal sleep <25mA

Deep Sleep <2 mA

LTE CAT 1 Connectivity

✖

✖

✖

✔

Optional

Optional

Optional

Optional

Digital Inputs

✖

2

2

2

3

3

3

3

CAN/CAN FD Bus

1x CAN

2x CAN FD

2x CAN FD

4x CAN FD

2x CAN

4x CAN

2x CAN FD/2x CAN

7x CAN

eMMC Storage

8 GB

8/16 GB

16/32 GB

16/32/64 GB

SD card up to 64 GB

SD card up to 128 GB

SD card up to 128 GB

SD card up to 128 GB

Starting Price

£259

£396.55

£597.40

£705

Contact Us

Contact US

Contact US

Contact US

Live CAN Bus Monitoring

✔

✔

✔

✔

✔

✔

✔

✔

Sleep & Wake On CAN

✔

✔

✔

✔

✔

✔

✔

✔

Analog Inputs

✖

2

2

2

4

4

4

4

Trigger Functions

✔

✔

✔

✔

✔

✔

✔

✔

Over The Air Updates

✖

✖

✖

✔

✖

✖

✖

✖

Real Time Clock

✔

✔

✔

✔

✔

✔

✔

✔

GNSS Positioning System

✖

✖

✔

✔

Optional

Optional

Optional

✔

FTPs for File Transfer

✖

✖

✖

✔

✖

✖

✖

✖

AWS S3

✖

✖

✖

✔

✖

✖

✖

✖

StreamLog*

✖

✖

✖

✖

✔

✔

✔

✔

IP Rating

IP 65

IP 65

IP 65

IP 50

IP 20

IP 65

IP 65

IP 65

USB 2.0 Interface

✔

✔

✔

✔

✔

✔

✔

✔

Open API

✔

✔

✔

✔

✖

✖

✖

✖

Supports J2534

✔

✔

✔

✔

✔

✔

✔

✔

Free Configuration Software ReXdesk

✔

✔

✔

✔

✖

✖

✖

✖

3D Accelerometer

✖

✖

✔

✔

Optional

Optional

Optional

✔

LIN Bus

✖

1

1

1

2

2

2

2

CAN Error Logging

✔

✔

✔

✔

✔

✔

✔

✔

Availability

Available Online

Available Online

Available Online

Enquire

Enquire

Enquire

Enquire

Enquire

J1939 Support

✔

✔

✔

✔

✔

✔

✔

✔

Gyroscope

✖

✖

✔

✔

Optional

Optional

Optional

Optional

Encryption Support (Licenced Feature)

✔

✔

✔

✔

✔

✔

✔

✔

ReXgen Series

K-Series

Rebel Series

Comparision List for ReXgen and Rebel Series data loggers

ReXgen 1
ReXgen 2
ReXgen 2 IMU
ReXgen Air
ReXgen Pro
K-Box
K-TC
K-AN8
K-IEPE
K-PT
Rebel LT

K-Series

Rebel LT

Functions
Description

Supported Protocols

OBD (CAN) ISO15765/ISO14229 (UDS)

CCP, xCPOnCAN

CAN monitoring (raw CAN messages or signals via CAN DBC)

J1939

CAN functions

Output CAN signals (applications include display units)

Create user-defined CAN messages for periodic transmission

Data storage format

FAT32 (PC readable)

Data logger configuration

Configuration via USB and SD card

Trigger Condition

Up to 20 configurable conditions

(>,< ,=, increment, decrement or on-change)

TrIgger Action

Up to 20 configurable triggers

Functions include start or stop, sample one-shot data, sample DTC, and read OBD data.

Configurable pre and post-trigger times

Configurable LED functions

Wake up time

Wake up from normal sleep mode logging starts within 20mSec

Wake up from power down mode; logging starts < 5 seconds

Data formats

Large quantities of recorded data can be conveniently converted to MDF, MDF4, MAT (Matlab), nCode, and by batch processing.

Power supply

4.7V to 36V DC (12V typical) internally fused with reverse protection

Power consumption @12V

Normal operation approx. 250mA to 350mA

Sleep mode approx. 80mA

Power down standby mode < 2mA

Wake up

WakeOnCAN function

PC interfaces

Isolated USB2.0 (Type B) - can be powered by USB

Functions

Description

CAN interfaces

2x CAN 2.0B Max 1MBit/s

LED

9x LEDs

Enclosure

Dimension (LxHxW): 115x26x105mm

Weight 400g

IP40

Stackable ABS

Environmental

-40degC to +80degC

Humidity max 90%

Data storage capability

Removable SDHC max 64GByte

Analog Inputs

Number of channels

4 bipolar single-ended inputs

Range

±10V

Resolution (ADC)

12 bits

Max sampling rate

1 KHz

Input impedance

>50K Ohms

Min/Max applied voltage

±40V

Digital Inputs/Outputs

Number of channels

3 unipolar single-ended inputs/outputs

Input switch thresholds

Low < 2V, High > 2.5V (up to 36V)

Output Drive details

Collector-emitter voltage 36V

Collector current (DC) 50mA max

max Saturation voltage <0.6V

Min-Max applied voltage

-0.5V to 36V

Optional

GNSS

K-TC

INF2204.02/INF2205.02/INF2206.02

The K-TC 2.0 modules belong to the Influx K-series instrumentation range for CAN applications and are stackable, fast, accurate and reliable temperature measurement devices. Ideal for applications requiring many thermocouples, such as vehicle durability during winter and summer testing.

The K-TC 2.0 modules CAN Bus settings, calibration and sampling rates are all easily configurable and stored in the K-TC 2.0 module even when not powered.

The input calibration and set-up of the K-TC 2.0 module are easily configurable via freely distributable Windows PC applications, Influx K-Cal and TC Logger software.

Logs and stores data to an integrated memory card independently (without the support of any other data logger).

Key Features

  • Each K-TC 2.0 unit has up to 8, 16 or 32 thermocouple connections at a 20Hz sampling rate.

  • Supports K, J and T-type thermocouples

  • Simple signal configuration using a DBC file

  • Supports logging of timestamped temperature data inside an integrated eMMC (8GB)

  • Supplied with configuration software Influx K-Cal for Windows® and configurable via a DBC file

  • Device drivers available for Windows® applications (32/64-bit)

  • Configuration and programming via CAN or USB interface

  • WakeOnCAN enables K-TC 2.0 modules to power up and power down in deep sleep mode

  • Measurement accuracy: ±1 degree C, Measurement resolution: 0.001 degree C

  • Instrumentation data time synchronised with recorded vehicle network data via CAN

  • Galvanic isolation (USB, CAN, Power, and TC Boards)

  • Free TC Logger software

Technical Specifications

K-AN8

INF2210

K-AN8 Analog Modules- for combined Voltages, Current and PWM Signals Accurate analog and digital sensor measurement data for CAN applications. A stackable, Easy, and cost-effective solution to measuring Analog and digital/P.W.M. sensors together in one module.

The K-AN8 includes our unique power down and WakeOnCAN feature for quick installation on long-term unattended fleet test vehicles. Accurate sensor measurement data is transmitted periodically on the CAN Bus, enabling multiple K-Series modules to be connected together.

The K-AN8 CAN Bus settings, calibration, and sampling rates are all configurable and stored even when not powered.

Key Features

  • 8 analog inputs with variable input sampling rates

  • (8 channels at 1k Hz, 4 channels at 2kHz, 2 channels at 10k Hz and 5kHz)

  • PWM: 3 inputs frequency measurements, counters or pulse measurements

  • Outputs: 4 Relay outputs. (Optional)

  • Regulated +5V and +24V output power supply for external sensors

  • Supplied with configuration software, Influx K-Cal for Windows® and configurable via a DBC file

  • Instrumentation data time synchronised with recorded vehicle network data via CAN

  • Galvanic isolation between modules (enclosure, power, CAN BUS and analog input module)

  • Analog channel over-voltage protection +150 Volt

  • Stackable ABS enclosure

Advantages

  • Combined Voltage, P.W.M./Digital measurements

  • Software switchable voltage input ranges from ±80V to ±10V

  • Very high accuracy- Analog ±0.0015%

  • High input impedance on Analog inputs

  • WakeOnCAN and power down deep sleep mode

Technical Specification

K-PT

INF2212

Our K-PT module is designed to connect PT100/1000 sensors to a K-Box or K-AN8 voltage measurement device that normally cannot support these sensors. The powered K-PT module enables PT100/1000 sensors to be connected via the D-Sub 9 terminals and will output the signal voltages to an Analogue measurement device.

Calibration and sampling rates can be configured using the freely distributed K-Cal software.

Key Features

  • Connects up to 4 RTD sensors to the K-Series K-Box/K-AN8 via the Analogue inputs

  • Simple signal configuration using a DBC file

  • Supplied with configuration software Influx K-Cal for Windows®

  • Refresh rates achievable (4 channels 20Hz)

  • ABS enclosure

Technical Specifications

ReXgen Air

INF2116.NN - Hardware Configurable (Up to 32 GB)

ReXgen Air is a compact, robust, accurate and cost-effective solution designed to become part of your fleet during production.

This is a progressive system that works on LTE CAT1. A data logger with onboard processing and telematics capabilities connects machines to the cloud or stores data locally.

Allows the encryption of data logs with the Secure Hash Algorithm (SHA).

An open platform that can be supported by any third-party tools and integrated into any data system. It is supplied with a free, powerful graphic interface application tool.

ReXgen Air allows you to build your system to maintain your data.

Key Features

  • Up to 4 CAN/CAN FD buses

  • x1 LIN bus

  • x2 Analog Inputs, x2 Digital inputs & x1 Power Stage Relay Driver (Optional)

  • Integrated 18Hz GNSS (u-Blox) and IMU (6 axis)

  • Encrypts data logs using Advanced Encryption Standard (AES)

  • Open API or XML Schema provided

  • Live CAN/CAN FD trace Monitoring

  • Enables Locking of the device using RSA data security

  • Micro USB 2.0 for data transfer and configuration

  • CAT -1 connectivity

  • Secure Data transfer using FTPs and Amazon S3

  • Supported Data formats -ASAM MDF4 MATLAB (.mat), CSV, ASC, BLF & TRC

  • Various sleep modes with low power consumption

  • x4 configurable LEDs

  • CAN/J1939 filters

  • Easily stackable and installable

  • Automotive grade Molex Mini50 connection system

Technical Specifications

Attention:

  • To set up a USB via the Molex connector, please specify this requirement when ordering, or the device must be sent back to Influx (as this requires some hardware modification).

*CEP - circular error probable

*FTPS- PROT P (Data channel encryption not supported.

* The region and category of the modem should be specified when ordering.

* Works with AT&T and T-Mobile in the USA.

Electrical Data

ReXgen Pro

LTE Modem Data

ELECTRICAL DATA

K-IEPE

INF2213

Our K-IEPE module is designed to connect IEPE sensors to a K-Box or K-AN8 voltage measurement device that normally cannot support IEPE sensors.

The powered K-IEPE module simply enables IEPE sensors to be connected via the BNC terminals and will output the signal voltages to the analog measurement device.

Calibration and sampling rates can be configured using the freely distributed K-Cal software.

Key Features

  • Connects to the K-Series K-Box/K-AN8 via the Analog inputs

  • Refresh rates achievable (4 channels 1kHz)

  • ABS enclosure

Advantages

  • Wide frequency range

  • Linear amplitude characteristics in a wide dynamic range

  • Ability to operate in severe ambient conditions (temperature, humidity, radiation and magnetic fields)

  • High mechanical reliability and durability at the expense of moving parts in the sensor

  • High vibration and shock resistance

  • No need for other power supplies for sensors

  • Compact structure and a large ratio of sensitivity to mass

Technical Specifications

ReXgen 2

INF2110.01/INF2110.02- Hardware Versions- 8/16 Gb- Current Range (Non-modular)

The Influx ReXgen 2 is a small, robust, powerful CAN bus data recorder. Targeted at applications that require a CAN 2.0, CAN FD and LIN flight data recorder. Supplied with ReXdesk, freely distributable software for the ReXgen 2. used for logger configuration and file exporter.

Key Features

  • 2x CAN 2.0/CAN FD buses, 1x LIN bus

  • 2x Digital Input channels, 2x Analog Input channels

  • Powerful graphic interface application tool

  • Supported Data formats -ASAM MDF4 MATLAB (.mat), CSV, ASC, BLF & TRC

  • Up to 16GByte eMMC storage

  • Micro USB 2.0 -High-speed connection to logger

  • Functions as an interface device and supports J2534 (Pass-thru)

  • Supports CAN monitoring RAW CAN signals, SAE J1939

  • Very low power consumption in sleep mode and WakeOnCAN, WakeOnAlarm & WakeOnSignal

  • CAN frame error detection ASAM MDF(*.mf4 format) -international standard data format

  • LEDs support status indication

  • IP65 enclosure protection

  • Plug and play, easily stackable and installable

Technical Specifications

Electrical Data

*Automotive customized connector is also available

ReXgen pro

Technical Data
Description

Technical Data
Description
Technical Data
Description
Functions
ReXgen Air
Function
Description

Technical Data
Description
Function
Description

Power supply

4.5 to 31V DC (isolated)

Power consumption

K-TC8 / K-TC16 / K-TC32

Normal operation

120mA at 12V / 140mA at 12V / 200mA at 12V

Power down standby mode

24mA at 12V / 25mA at 12V / 30mA at 12V

Configuration

Via CAN bus with K-Cal for calibration. Via USB with TC Logger SW for logging configurations stored in the device

Interfaces (Isolated)

CAN bus (max 1000 kbps) and USB 2.0

Storage

8 GB eMMc

PC Interfaces

USB2.0 Type B (isolated)

Enclosure

Dimension (LxHxW): 115x56(K-TC8) / 79(K-TC16) / 149(K-TC32) x 105mm

Weight 450g(K-TC8), 570g(K-TC16), 900g(K-TC32)

IP 40 IP 65 (With all thermocouples plugged in)

ABS/Aluminum Allow* (depending upon the stock availability)

Environmental

-40°C to +85°C

Humidity max 90%

Thermocouple Inputs

K, J, T-type

Accuracy ± 1°C

Measurement: -200 °C to 1250 °C

Connection type

Thermocouples: mini K, J ,T-Type (galvanically connected)

Thermocouple Inputs

Number of channels

K-TC8: 8 channels, K-TC16: 16 channels, K-TC32: 32 channels (group of 8 isolated/each galvanically connected)

Channel Input Types

K, J, T

Measurement Range

(-)200°C to (+)1200°C

Max Sampling Rate

20 Hz per channel

Max applied voltage

± 3.3 V

Peak Galvanic Isolation Voltage (from all other modules and power supplies)

Three-wire CAN Bus

780 V

Four-wire USB Bus

840 V

Two-wire power module

560V

Power supply

6 to 36V DC.

Interfaces

CAN Bus

PC interfaces

None

Enclosure

Dimension (L115xH56xW105)

Weight 450g

IP65

ABS

Environmental

-40°C to +85°C Humidity max 90%

Output Voltages

5V and 24V (Max current drawn 80 mA combined)

Analog Inputs

Number of channels

8 Bipolar differential inputs

Accuracy

±0.0015%

Software switchable Range

±80V, ±40V, ±20V, ±10V

Resolution (ADC)

16 Bit

Max Sampling Rate

1 KHz (all 8 channels), 2 KHz (4Channels), 10 KHz (2 Channels)

Input Impedance

> 4 MOhm

Min-Max Applied Voltage

±75 V vs Analog Ground, ±150 V between Analog inputs

Digital Input / Output

Number of channels

×4 unipolar single-end hardware configured as input or output.

Input switching thresholds

Low < 1.5V

High > 2.0V (up to 12V)

Input leakage current

< 10nA

Output states

(Optional) Open collector & 510Ohm

Output drive capability

45V max

Collector current (DC)

10mA max

Saturation voltage (OK on)

< 0.15V

Equivalent on-resistance

< 510Ohm

Leakage current at OK off

< 5uA

Min-Max applied voltage

Digital input -8V to +12V; Digital output 0V to +40V power supply, which limits the current to 10mA

PWM

3 digital inputs frequency measurements up to 100KHz or pulse measurements. (min 100 Nanoseconds, min time between pulses 10 microseconds)

Measurement inputs

4

Type of measured sensors

PT100/1000

Measurement range

-200degC to +850degC

Linearization

Standard tables for different types of ALPHA

Internal resolution

18 Bit

Internal sampling rate per channel.

6.25kHz

Measurement data rate per channel.

1, 2, 5, 10, 20 Hz

HW HW input filter

Input filter common mode; Output filter on the amplifier; Differential-Mode Corner Frequency 7.6Hz, Common-Mode Corner Frequency: 159Hz

SW input filter

A digital filter in the ADC module is automatically adjusted to the sampling rate. With the current setting (sampling at 6.25kHz), the filter has a frequency of 3kHz

Broken sensor detection

Yes

Measurement current

The current changes, depending on the resistance of the sensor, within the range: 212-224µA

Gain error at 25degC

± 0.1% of measured value

Offset and scaling error

±1K

Gain drift

±10ppm/K of measured value

Zero drift

±5 mK/K

CAN channel Isolation

1000VDC minimum

CAN power supply Isolation

CAN and Power are galvanically connected

CAN interface

CAN 2.0B, up to 1Mbit/s

Configuration

Configuration with K-Box Cal application by company protocol

Power supply

4.5V to 36V DC.

Power consumption

Typ. 1.9W

Designation housing

ABS

Protection class

IP65

Weight

450g

Dimensions

115x46x105mm

CAN power supply

Two 9 pin D-type connectors with duplicate signals

Signal inputs

Two channels are integrated into a 9 pin D-type connector

Operation temperature range

-40degC to +85degC

CAN Interfaces

Up to 4 x CAN/CAN FD

ISO 11898-1: Compliant with CAN (up to 1 Mbit/s)

ISO & Bosch CAN FD (up to 8 Mbit/s)

Conforms to CAN protocol version 2.0 - part A, B

Up to 20000 mps

Meets the requirements of ISO 11898-2:2016 & ISO 11898-5:2007 physical layer standards

CAN/CAN FD Functions

CAN/CAN FD Bit timing selection

SAE J1939 support (Source Address, Destination Address & PGN Filters)

Silent Mode Configurable Periodic CAN Transmission CAN DBC Support

CAN frame error detection

Identifiers

Compliant with CAN specifications 2.0A (11-Bit ID) and 2.0B (29-Bit ID)

CAN Error Frames

Support for logging CAN error frames (bit-stuffing, form, CRC, bit, acknowledgement)

Retransmission

Configurable retransmission of frames that have lost arbitration or been disturbed by errors

Prescaling

Pre-scale CAN frames to record e.g., by time (per X ms) or by data (e.g., if byte X or Y changes)

Transmit

Transmit lists of CAN frames per channel (periodic) - e.g., for OBD2 requests- Capability to link multiple CAN messages

LIN Interface

1 x LIN (Master & Slave mode)

Compliant with LIN Bus Specifications 1.3, 2.0 and 2.1 and are compliant to SAE J2602

LIN channel can be configured as a LIN subscriber/publisher with support for LIN data transmission

Support for custom frame lengths

Parallel CAN/LIN

Record data from up to upto 4 x CAN channels + 1 x LIN channels, simultaneously

Connector

Molex Mini50 Dual Row 24 Pin connector (enables the device to be easily and robustly installed in production machines)

LTE

CAT 1 (see uBlox Lara R2 Series)/Quectel CAT 4

Inputs

2 x Digital and 2 x Analog

Bit-Rate Auto-Detect

Bit rate can be auto-detected or set manually

Instrumentation Supply

5 Volts (Ensure that current draw is not more than 100mA)

Real-Time Clock

Yes - CAN frames are date & timestamped with 10 microsecond resolution (battery backup)

The RTC can be configured to match local time zones (default: UTC)

The RTC can be auto-synced via 3G/4G LTE Timestamp or a CAN message (e.g., from the internal GNSS timestamp)

File Split

Configurable log file split size (by size: 10-500 MB and/or by time period)

Unique Device ID

Each device has a globally unique ID ensuring unique log file naming

Signed Firmware

Firmware updates are digitally signed to verify that they are from a trusted source

Cyclic Logging

Enabled by default

Positioning Sensors

GNSS Module

M8U-30 Hz (supports dead reckoning) / M8Q-18Hz (does not support dead reckoning) Supports 4 position systems with highly accurate positioning.

GNSS Receiver Type

72-channel, GNSS L1C/A, SBAS L1C/A, QZSS L1C/A, QZSS L1-SAIF, GLONASS L1OF, BeiDou B1I , Galileo E1B/C

Position Accuracy

2.0 m CEP*

Sensitivity

Tracking/Navigation: 167 dBm | Cold starts: 148 dBm

Acquisition

Cold starts: 26s

Reacquisition: 2 s

Antenna

External FAKRA antenna (3m included) Code C

Accuracy

Velocity: 0.05m/s

Heading: 0.3 degrees

Others

IMU

6D IMU

Accelerometer

±2/±4/±8/±16 g full scale

Gyroscope

±125/±250/±500/±1000/±2000 dps full scale

PC Interfaces

Micro USB Type AB 2.0 interface (Standard version)

USB interface via the Molex Mini50 connector (Optional)

Data Storage Capability

Up to 32 GB eMMC storage (non-removable) (uses FIFO logic once the eMMC is full)

Supported Protocols

CAN Monitoring (RAW CAN signals, SAE J1939 support, FMS, CANopen, NMEA 2000, OBD2, CAN FD, UDS)

LEDs

4

Triggering

Trigger on CAN ID, CAN Signal, Digital Input.

Trigger on DM1 counter.

Filters

200* regular/extended ID filters per channel (range, acceptance)

File Format Supported

RXD, RXE, ASAM MDF (.mf4), CSV, MATLAB, ASC, BLF, TRC

Warranty

12 months from the date of invoice.

Support

Yes, during the warranty period

Origin

UK

Protocol

FTP/FTPS/HTTP/HTTPS

Data Transfer Protocol

FTPS and Amazon S3

Security Functions

Encryption of data logs, Locking of device.

Encryption Standard

RSA* (for locking device) and AES* (for log data)/GDPR/CCPA/SHA

Data Logger Configuration

Supplied with Influx ReXdesk configuration software, API, CLI

Software

Supplied with Influx ReXdesk configuration software, API, CLI

Free open Source ReXcloud platform for managing devices and data via your browser

Free open source asammdf software & API, DBC converting & plotting MF4 data

Free data convertors, CLI based/ .net DLL for converting RXD into RXE, ASAM MDF (.mf4), CSV, MATLAB, ASC, BLF, TRC

Free open-source AWS Lambda, Example Application for data processing/ Supports AWS time stream/DB to integrate with third party dashboard

Firmware

Supports free firmware updates for adding features

Analog Input

Number of channels

2 x Bipolar single-ended inputs

Range

± 10 V

Resolution (ADC)

12 Bit

Max sampling rate

1 kHz

Input Impedance

> 50 K Ohms

Safe Applied Voltage

±28 V

Digital Input

Number of channels

2 x Unipolar single-ended inputs

Input Switching Thresholds

Low < 0.8 V, High > 2.5 V (up to 28V)

Safe Applied Voltag

28 V

Integrated GPRS

LTE modem

Category

Professional-grade uBlox Lara R2 Series LTE Cat1/ Quectel EC 20/25 CAT 4*

LTE CAT1 Bands

LTE FDD Bands: 1(2100 MHz) ,2(1500 MHz), 3(1800 MHz),4(1700 MHz), 7(2600 MHz), 8(900 MHz), 12(700 MHz), 13(700 MHz), 19(850 MHz), 20(800 MHz), 28(700 MHz)

Receiver input Sensitivity

-98dBm to -114dBm: 700MHz to 2100MHz

Coverage

Global * Available on request

Antenna

External FAKRA antenna (3m included) Code D

Server Interface

FTP/FTPS/S3

SIM Slot

External nano sim slot/ esim available on request

Over-The-Air (OTA)

Configuration & firmware over-the-air (COTA/FOTA). Configurable sync rate. Optionally disable

Heartbeat

Yes

Data Upload State

Yes

CAN Heartbeat

Optionally transmit heartbeat CAN frame with device info, device status, storage used RTC time & config-details

Snapshot

Decode and send CAN signals periodically to the server

HTTPS

Data & over-the-air updates can be sent via HTTPS (TLS 1.2) for secure transfer

User Policies

Fully customize access rights across devices and end users through S3 policies * (when using AWS upload)

Credential Encryption

S3 server credentials can be encrypted in the config on the device

BUS & Signals

Operating Voltage

Power supply - OBD

+5V to +27V

Power supply - USB

+4.5 to +5.5V

CAN/CAN FD

+2 to +3V

LIN

0 to +24V

Digital Input

0 to +28V

Analog input

± 10V

Transceiver Protection (CAN)

Bus fault protection: ±58 V

Thermal-shutdown protection (TSD)

Common mode input voltage: ± 12V

TXD dominant timeout (prevents network blocking in the event of a failure)

Under-voltage protection

Transceiver Protection (LIN)

±8 kV HBM ESD, ±2 kV CDM, ± bus Fault

TXD dominant timeout (to prevent the LIN node from permanently driving the LIN Bus dominant)

Power Voltage

5V for external sensor (current consumed should be less than 100mAmp)

Enclosure

PC+ ABS

IP Rating

IP 50

Dimension

L - 100 mm, W - 65 mm, H – 30 mm

Weight

112 Grams

Mounting Holes

4 mounting holes and screws

Stackable

Yes

Environmental Tolerance

Working temperature -40degC to +85degC; Humidity max 90%

Silent Mode

Listen only mode available (configurable Silent mode)

Power Saving

Wake Up On CAN, Wake up on Movement, Power Down Mode, Sleep Modes

Power Safe

100% power safe data logging - no file corruption when disconnected or in sleep mode

Power Consumption

Normal (usage without Cloud) <120mA at 12V

Normal (usage with Cloud) <300mA

Normal sleep <21mA

Deep sleep <10mA

Protection

Reverse voltage protection on CAN-bus supply

Functions

ReXgen Air Pro

CAN Interfaces

Up to 4 x CAN/CAN FD (Arbitration Rate 500 Kbps & Data Rate 8 Mbps) ISO 11898-1: Compliant with CAN (up to 1 Mbit/s) ISO & Bosch CAN FD (up to 8 Mbit/s) Conforms to CAN protocol version 2.0 - part A, B Max 20000 mps Meets the requirements of ISO 11898-2:2016 & ISO 11898-5:2007 physical layer standards

CAN/CAN FD Functions

Supports custom baud rates CAN/CAN FD Bit timing selection Silent Mode Configurable CAN DBC Support CAN frame error detection

LIN Interface

2 x LIN (Master & Slave mode) (optional)

Data Storage

32GB eMMC

Secure Element

Configurable

Wi-Fi

Murata 1MW Wi-Fi module

Wi-Fi Antenna

External FAKRA Code Z

LTE

CAT 4

LTE Antenna

FAKRA Code D

Data Transfer Protocol

Configurable app

Inputs

2x Digital and 3x Analog

Positioning & IMU Sensors

IMU

6 Axis accelerometer ( Max sampling rate 1KHz)

Accelerometer

±2/±4/±8/±16 g full scale (max sampling rate-1KHz)

Gyroscope

±125/±250/±500/±1000/±2000 dps full scale (max sampling rate-1KHz)

GNSS Antenna

FAKRA Code C

GNSS Receiver Type

72-channel, GNSS L1C/A, SBAS L1C/A, QZSS L1C/A, QZSS L1-SAIF, GLONASS L1OF, BeiDou B1I, Galileo E1B/C

Position Accuracy**

2.0 m CEP*

Acquisition**

Cold starts: 26s

Reacquisition: 2 s

GPS Accuracy**

Velocity: 0.05m/s

Heading: 0.3 degrees

Altitude: not specified

Clock

Battery backed RTC

Transceiver Protection

Bus fault protection: ±58 V

Thermal-shutdown protection (TSD)

Under-voltage protection

Enclosure

Aluminium

IP Rating

IP65

Dimension

L - 159.4mm, W - 81mm, H – 27.8mm

Weight

300g

Mounting Holes

4 mounting holes and screws

Environmental Tolerance

Working temperature -40degC to +70degC; Humidity max 90%

Power Saving

Power Down Mode, Sleep Modes Wake Up On CAN, Wake up on Movement, Digital Input,

Analog input

Number of channels

3 x Bipolar single-ended inputs

Range

± 10V

Resolution (ADC)

12 Bit

Max sampling rate

1 kHz

Input Impedance

> 50 K Ohms

Safe Applied Voltage

± 28 V

Digital Input

Number of channels

2 x Unipolar single-ended inputs (1x PWM)

Input Switching Thresholds

Low < 0.8 V, High > 2.5 V (up to 28V)

Safe Applied Voltage

±28 V

Integrated GPRS

LTE modem

Category

CAT 4 (Regional or Global)

SIM

Nano/ Soldered SIM (optional)

LTE CAT1 Bands

LTE FDD: B1/B2/B3/B4/B5/B7/B8/B12/B13/B18/B19/B20/B25/B26/B28 LTE TDD: B38/B39/B40/B41

Receiver input Sensitivity

-98dBm to -114dBm: 700MHz to 2100MHz

Antenna

External FAKRA Code D

Interfaces

LTE CAT4, Wi-Fi (Bluetooth & Ethernet in future upgrades)

Supported Protocols

CAN or CAN FD Monitoring (RAW CAN signals, SAE J1939 support) UDS, OBD, XCP

LEDs

8

Triggering

Trigger on CAN ID, CAN Signal, and Digital Input.

Trigger on DM1 counter.

Log files accessible Via.

ReXdesk Software or on cloud

File Format Supported

ASAM, MDF, MF4, Peak TRC, CSV, MATLAB, ASC, BLF, RXD, Parquet

Data Logger Configuration

Supplied with Influx ReXdesk configuration software or XML-based Configuration

BUS & Signals

Operating Voltage

Power supply - OBD

6.5V to 27V

CAN FD

+2 to +3V

LIN

0 to +24V

Digital Input

0 to +28V

Analog input

± 10V

Measurement inputs

4

Internal resolution

18 bit

Internal sampling rate per ch.

6.25kHz

Measurement data rate per ch.

4 channels: 1kHz. CAN bus: 1Mbit/s

SW input filter

A digital filter in the ADC module is automatically adjusted to the sampling rate

High pass filter

13.8Hz

Bandwidth

21.8Hz

Operational safety

-0.7V to +24V permanent, additional

Device safety

-0.7V to +24V permanent, additional ESD protection

Input impedance

>10K

Broken sensor detection

Yes

Typical SNR @ 30kHz Band Width

Sampling @6.25Hz: 102dB

Linearity

ADC ±0.75 LSB

Current source

5.1mA ± 2%

Voltage

24V

Output power

Maximum total (for 4 channel) current: 60mA

Channel/ power supply Isolation

1000 VDC minimum

Sensor excitation/ power supply Isolation

1000 VDC minimum

CAN channel Isolation

1000 VDC minimum

CAN power supply Isolation

CAN and power are galvanically connected

Configuration

Configuration with K-Box Cal application by company protocol

Power supply

4.5V to 36V DC.

Power consumption

Typ. 2.6W

Housing

ABS

Dimensions/ Weight/ Protection Class

D: (128x46x105mm); W: 450g; PC: IP65

CAN/ Power supply

Two 9-pin D-Type connections with duplicate signals

Signal Inputs

BNC Connector

Operating temperature range

-40degC to +85degC

Functions

ReXgen 2

CAN Interfaces

2 x CAN/CAN FD

ISO 11898-1: Compliant with CAN (up to 1 Mbit/s)

ISO & Bosch CAN FD (up to 8 Mbit/s)

Conforms to CAN protocol version 2.0 - part A, B

Max 20000 mps

Meets the requirements of ISO 11898-2:2016 & ISO 11898-5:2007 physical layer standards

CAN/CAN FD Functions

Supports custom baud rates

CAN/CAN FD Bit timing selection

SAE J1939 support (Source Address, Destination Address & PGN Filters)

Silent Mode Configurable

CAN DBC Support

CAN frame error detection

LIN Interface

1 x LIN (up to 20 K Baud with LIN-Compatible Output Driver)

Inputs

2 x Digital and 2 x Analog (max sampling rate-1KHz)

PC Interfaces

Rugged Micro USB 2.0

(Datalogger mode and J2534)

Data Storage Capability

8 or 16 GB Inbuilt eMMC storage (uses FIFO logic once the eMMC is full)

Supported Protocols

CAN Monitoring (RAW CAN signals, SAE J1939 support)

LEDs

2

Triggering

Trigger on CAN ID, CAN Signal, and Digital Input.

Trigger on DM1 counter.

Data Storage Format

Log files accessible via ReXdesk Software

File Format Supported

ASAM MDF (.mf4), Peak TRC, CSV, MATLAB, ASC, BLF

Data Logger Configuration

Supplied with Influx ReXdesk configuration software, XML based

Analog Input

Number of channels

2 x Bipolar single-ended inputs

Range

± 10 V

Resolution (ADC)

12 Bit

Max sampling rate

1 kHz

Input Impedance

> 50 K Ohms

Safe Applied Voltage

± 28 V

Digital Input

Number of channels

2 x Unipolar single-ended inputs

Input Switching Thresholds

Low < 0.8 V, High > 2.5 V (up to 28V)

Safe Applied Voltage

± 28 V

BUS & Signals

Operating Voltage

Power supply - OBD

+5V to +27V

Power supply - USB

+4.5 to +5.5V

CAN FD

+2 to +3V

LIN

0 to +24V

Digital Input

0 to +28V

Analog input

± 10V

Transceiver Protection(CAN)

Bus fault protection: ±58 V

Thermal-shutdown protection (TSD)

Common mode input voltage: ± 12V

TXD dominant timeout (prevents network blocking in the event of a failure)

Under-voltage protection

Transceiver Protection (LIN)

±8 kV HBM ESD, ±2 kV CDM, ± bus Fault

TXD dominant timeout (to prevent the LIN node from permanently driving the LIN Bus dominant)

Power Voltage

5V for external sensor (current consumed should be less than 10mAmp)

Enclosure

PC+ ABS

IP Rating

IP65

Dimension

L - 100 mm, W - 73.5 mm, H – 27.4 mm

Weight

164 gms

Mounting Holes

4 mounting holes and screws

Stackable

Yes

Environmental Tolerance

Working temperature -40degC to +85degC; Humidity max 90%

Silent Mode

Listen only mode available (configurable Silent mode)

Power Saving

Wake Up On CAN, Wake up on Movement, Power Down Mode, Sleep Modes

Power Safe

100% power safe data logging - no file corruption when disconnected or in sleep mode

Protection

Reverse voltage protection on CAN-bus supply

Power Consumption

Normal Operation: <75 mA at 12 V

Normal sleep <17mA

Deep Sleep <2 mA

Detailed Documentation
Detailed Documentation
Detailed Documentation
Detailed Documentation
Detailed Documentation

K-Box

INF2201

K-Box Multi-DAQ Modules aid in measuring Thermocouples, Voltages, Currents and PWM. These include our unique power down and WakeOnCAN feature and can be stacked with all of our K-series instrumentation modules.

K-Box transmits the Data periodically on the CAN Bus for accurate sensor measurement.

Key Features

  • Software switchable voltage input ranges from ±80V to ±10V

  • Up to 8 thermocouple connections at up to 10 Hz sampling rate

  • 8 Analog inputs with variable input sampling rates (8 channels at 1kHz, 4 channels at 2kHz and 2 Channels at 10kHz)

  • Very high accuracy-Analog ±0.0015%,Thermocouples ±1°C

  • PWM: 3 inputs frequency measurements, counters or pulse measurements

  • Outputs: 4 Relay outputs (optional)

  • Regulated +5V and +24V output power supply for external sensors

  • Supplied with configuration software, Influx K-Cal for Windows® and configurable via a DBC file

  • Instrumentation data time synchronised with recorded vehicle network data via CAN

  • Galvanic isolation between modules (enclosure, power, CAN BUS and Analog input module and thermocouple input module)

  • Measurement accuracy: ±1° C

  • Measurement resolution: 0.1°C

  • Analog channel over-voltage protection ±150 Volt

Advantages

  • Combined Voltage, Thermocouple and PWM/Digital measurements

  • Cold junction compensation for accurate thermocouple measurement

  • High input impedance on Analog inputs

  • WakeOnCAN and power down deep sleep mode

Technical Specification

Technical Data
Description

Power supply

6V to 36V DC.

Interfaces

CAN Bus

PC interfaces

None

Enclosure

Dimension (L115xH79xW105) / Weight 450g / IP65 / ABS

Environmental

-40°C to +85°C Humidity max 90%

Output voltages

5V and 24V (Max current drawn 80 mA combined)

Analog Inputs

Number of channels

8 Bipolar differential inputs

Accuracy

±0.0015%

Software switchable range

±80V, ±40V, ±20V, ±10V

Resolution (ADC)

16 Bit

Max Sampling Rate

1 KHz (all 8 channels), 2 KHz (4Channels), 10 KHz (2 Channels)

Input impedance

> 4 M Ohm

Max input voltage

±75 Analog Ground, ±34 V Analog inputs

Thermocouple Inputs

Number of channels

8 J/K/T-type inputs

Accuracy

±1°C accuracy

Measurement Range

Measurement: -200 °C to 1250 °C

Max Sampling Rate

10 Hz (all 8 channels)

Maximum input voltage

±3.3 V

Digital Input / Output

Number of channels

×4 unipolar single-ended hardware configured as inputs or outputs

Input switching thresholds

Low < 1.5V

High > 2.0V (up to 12V)

Input leakage current

< 10nA

Output states

(Optional) Open collector - 510 Ohm

Output drive capability (OK):

Collector-emitter voltage

45V max

Collector current (DC)

10mA max

Saturation voltage (OK on)

< 0.15V

Equivalent on-resistance

< 510Ohm

Leakage current at OK off

< 5uA

Min-max applied voltage

Digital input -8V to +12V; Digital output 0V to +40V power supply, which limits the current to 10mA

PWM

3 digital input frequency measurements up to 100kHz or pulse measurements. (min 100 Nano sec) (between pulses 10 microseconds)

Detailed Documentation
657KB
ReXgen1.pdf
pdf
PDF Download
1MB
Rexgen 2 & IMU flyer_V1.5.pdf
pdf
PDF Download
1MB
K-Series Flyer.pdf
pdf
Downloadable pdfs for all K-Series instruments
1MB
Rebel LT_flyer.pdf
pdf
PDF Download
682KB
K-Tc Flyer.pdf
pdf
PDF Download
506KB
KAN8 Flyer.pdf
pdf
PDF Download
508KB
KIEPE&PT Flyer.pdf
pdf
PDF Download
1MB
ReXgen Air_V1.2.pdf
pdf
PDF Download
509KB
KIEPE&PT Flyer.pdf
pdf
PDF Download
1MB
Rexgen 2 & IMU flyer_V1.5.pdf
pdf
PDF Download
541KB
KBox Flyer.pdf
pdf
PDF Download
Cover

ReXgen 1

Cover

ReXgen 2

Cover

ReXgen 2 IMU

Cover

ReXgen Air

ReXgen 1
Cover

Rebel LT

Cover

K-Box

Cover

K-AN8

Cover

K-TC

Cover

K-IEPE

Cover

K-PT 100/1000

K-TC 8/16/32
K-PT 100/1000
ReXgen Air
K-IEPE