Functions | Description |
---|---|
Supported Protocols
OBD (CAN) ISO15765/ISO14229 (UDS)
CCP, xCPOnCAN
CAN monitoring (raw CAN messages or signals via CAN DBC)
J1939
CAN functions
Output CAN signals (applications include display units)
Create user-defined CAN messages for periodic transmission
Data storage format
FAT32 (PC readable)
Data logger configuration
Configuration via USB and SD card
Trigger Condition
Up to 20 configurable conditions
(>,< ,=, increment, decrement or on-change)
TrIgger Action
Up to 20 configurable triggers
Functions include start or stop, sample one-shot data, sample DTC, and read OBD data.
Configurable pre and post-trigger times
Configurable LED functions
Wake up time
Wake up from normal sleep mode logging starts within 20mSec
Wake up from power down mode; logging starts < 5 seconds
Data formats
Large quantities of recorded data can be conveniently converted to MDF, MDF4, MAT (Matlab), nCode, and by batch processing.
Power supply
4.7V to 36V DC (12V typical) internally fused with reverse protection
Power consumption @12V
Normal operation approx. 250mA to 350mA
Sleep mode approx. 80mA
Power down standby mode < 2mA
Wake up
WakeOnCAN function
PC interfaces
Isolated USB2.0 (Type B) - can be powered by USB
Functions
Description
CAN interfaces
2x CAN 2.0B Max 1MBit/s
LED
9x LEDs
Enclosure
Dimension (LxHxW): 115x26x105mm
Weight 400g
IP40
Stackable ABS
Environmental
-40degC to +80degC
Humidity max 90%
Data storage capability
Removable SDHC max 64GByte
Analog Inputs
Number of channels
4 bipolar single-ended inputs
Range
±10V
Resolution (ADC)
12 bits
Max sampling rate
1 KHz
Input impedance
>50K Ohms
Min/Max applied voltage
±40V
Digital Inputs/Outputs
Number of channels
3 unipolar single-ended inputs/outputs
Input switch thresholds
Low < 2V, High > 2.5V (up to 36V)
Output Drive details
Collector-emitter voltage 36V
Collector current (DC) 50mA max
max Saturation voltage <0.6V
Min-Max applied voltage
-0.5V to 36V
Optional
GNSS