Page cover image

K Box Pinouts (INF 2201)

K-Box instrumentation device

The CAN Connectors (2x DB9 CAN Connectors)

The CAN Connectors are 1x Male and 1x Female 9-pin Standard D Type Connectors with nuts.

Female 9-pin Standard D-Type Connector
Male 9-pin Standard D Type Connector

Pin No

Pin Function

Pin 1

Digital Output 4 or +4.5V Instrumentation Supply Voltage, ensure that current draw is not more than 100mA

Pin 2

CAN Bus Low Signal

Pin 3

Ground

Pin 4

Digital Input or Output 1 - Do not apply voltages outside of the 0 to +12V range when used as an input. When used as an Output, ensure that the current drawn is not more than 100mA. More information on the use of this pin can be found in Appendix 2 and 3

Pin 5

Power Ground

Pin 6

Digital Input or Output 3

Pin 7

CAN Bus High Signal

Pin 8

Digital Input or Output 2 - Do not apply voltages outside of the 0 to +12V range when used as an input. When used as an Output, ensure that the current drawn is not more than 100mA. More information on the use of this pin can be found in Appendix 2 and 3

Pin 9

4.5-36V Supply Voltage

WARNING:

The ADC Connector

The ADC Connector is a Male 25-pin Standard D-Type Connector with nuts.

Male 25-pin Standard D-Type Connector

Pin No

Pin Function

Pin 1

+24V Output - ensure that the current drawn is not more than 75mA

Pin 2

+5V Output - ensure that the current drawn is not more than 75mA

Pin 5

Analog Ground

Pin 6

Analog Input 0 + ve (do not apply voltages outside the voltage range the K-Box is configured for).

Pin 7

Analog Input 1 + ve (do not apply voltages outside the voltage range the K-Box is configured for).

Pin 8

Analog Input 2 + ve (do not apply voltages outside the voltage range the K-Box is configured for).

Pin 9

Analog Input 3 + ve (do not apply voltages outside the voltage range the K-Box is configured for).

Pin 10

Analog Input 4 + ve (do not apply voltages outside the voltage range the K-Box is configured for).

Pin 11

Analog Input 5 + ve (do not apply voltages outside the voltage range the K-Box is configured for).

Pin 12

Analog Input 6 + ve (do not apply voltages outside the voltage range the K-Box is configured for).

Pin 13

Analog Input 7 + ve (do not apply voltages outside the voltage range the K-Box is configured for).

Pin 14

Ground Out

Pin 15

Ground Out

Pin 17

Analog Ground

Pin 18

Analog Input 0 - ve (do not apply voltages outside the voltage range the K-Box is configured for).

Pin 19

Analog Input 1 - ve (do not apply voltages outside the voltage range the K-Box is configured for).

Pin 20

Analog Input 2 - ve (do not apply voltages outside the voltage range the K-Box is configured for).

Pin 21

Analog Input 3 - ve (do not apply voltages outside the voltage range the K-Box is configured for).

Pin 22

Analog Input 4 - ve (do not apply voltages outside the voltage range the K-Box is configured for).

Pin 23

Analog Input 5 - ve (do not apply voltages outside the voltage range the K-Box is configured for).

Pin 24

Analog Input 6 - ve (do not apply voltages outside the voltage range the K-Box is configured for).

Pin 25

Analog Input 7 - ve (do not apply voltages outside the voltage range the K-Box is configured for).

The Thermocouple Connectors

The Thermocouple Connectors on the K-Box are miniature-size flat-type sockets.

Miniature-size flat-socket type thermocouple connectors

IEC Connector

Pin Function

Top

+ Signal from the Thermocouple

Bottom

K Signal from the Thermocouple

The dimensions of the Male Flat Type Miniature Size Thermocouple Plug that you would plug into it are as follows:

Dimensions of the Male Flat Type Miniature Size Thermocouple

Note:

  • Pins not mentioned in the description table(s) are NC.

Last updated