K-AN8
(INF 2210)
Last updated
(INF 2210)
Last updated
(2x DB9 CAN Connectors)
The CAN Connectors are 1x Male and 1x Female 9-pin Standard D Type Connectors with nuts.
Pin No
Pin Function
Pin 1
Digital Output 4 or +4.5V Instrumentation Supply Voltage, ensure that the current drawn is not more than 100mA
Pin 2
CAN Bus Low Signal
Pin 3
Ground
Pin 4
Digital Input or Output 1 - Do not apply voltages outside of the 0 to +12V range when used as an input. When used as an Output, ensure that the current drawn is not more than 100mA. More information on the use of this pin can be found in Appendix 2 and 3
Pin 5
Power Ground
Pin 6
Digital Input or Output 3
Pin 7
CAN Bus High Signal
Pin 8
Digital Input or Output 2 - Do not apply voltages outside of the 0 to +12V range when used as an input. When used as an Output, ensure that the current drawn is not more than 100mA. More information on the use of this pin can be found in Appendix 2 and 3
Pin 9
4.5-36V Supply Voltage
The ADC Connector is a Male 25-pin Standard D-Type Connector with nuts.
Pin No
Pin Function
Pin 1
+24V Output - ensure that the current drawn is not more than 75mA
Pin 2
+5V Output - ensure that the current drawn is not more than 75mA
Pin 5
Analog Ground
Pin 6
Analog Input 0 + ve (do not apply voltages outside the voltage range the K-AN8 is configured for).
Pin 7
Analog Input 1 + ve (do not apply voltages outside the voltage range the K-AN8 is configured for).
Pin 8
Analog Input 2 + ve (do not apply voltages outside the voltage range the K-AN8 is configured for).
Pin 9
Analog Input 3 + ve (do not apply voltages outside the voltage range the K-AN8 is configured for).
Pin 10
Analog Input 4 + ve (do not apply voltages outside the voltage range the K-AN8 is configured for).
Pin 11
Analog Input 5 + ve (do not apply voltages outside the voltage range the K-AN8 is configured for).
Pin 12
Analog Input 6 + ve (do not apply voltages outside the voltage range the K-AN8 is configured for).
Pin 13
Analog Input 7 + ve (do not apply voltages outside the voltage range the K-AN8 is configured for).
Pin 14
Ground Out
Pin 15
Ground Out
Pin 17
Analog Ground
Pin 18
Analog Input 0 - ve (do not apply voltages outside the voltage range the K-AN8 is configured for).
Pin 19
Analog Input 1 - ve (do not apply voltages outside the voltage range the K-AN8 is configured for).
Pin 20
Analog Input 2 - ve (do not apply voltages outside the voltage range the K-AN8 is configured for).
Pin 21
Analog Input 3 - ve (do not apply voltages outside the voltage range the K-AN8 is configured for).
Pin 22
Analog Input 4 - ve (do not apply voltages outside the voltage range the K-AN8 is configured for).
Pin 23
Analog Input 5 - ve (do not apply voltages outside the voltage range the K-AN8 is configured for).
Pin 24
Analog Input 6 - ve (do not apply voltages outside the voltage range the K-AN8 is configured for).
Pin 25