LogoLogo
Home
  • 🏠Home
  • Cables & Device Pinouts: Influx Product Range
    • Cables
      • INF 41XX.XX
        • INF4100: Rebel Start-Up Kit Harness
          • Data Logger Socket.
          • CAN0/CAN1/Kline/PWR Connector
          • CAN 1 Connector
          • CAN 2 Connector
          • CAN 3 Connector
          • Digital and Analog Connector
        • INF4102: 180-degree OBD Type-B Cable to Rebel Data Logger Adapter Cable
          • 25-Way D-Type
          • OBDII Connector
        • INF4103: 180-degree OBD Type-B to 9-Way Sub D Adapter Cable
          • 9-Way D-Type
          • OBDII Connector
      • INF 42XX.XX
        • INF4202: Rebel FlexRay/CAN Breakout Cable
          • Expansion Port Connector
          • FlexRay 1 Connector
          • FlexRay 2 Connector
          • CAN 4 and LIN 3 Connector
          • CAN 5 Connector
          • CAN 6 Connector
        • INF4203: Rebel LT CAN Bus Breakout Cable
          • OBD and INST Connector
          • CAN0/PWR/K-Line Connector
          • AUX/CAN 1 Connector
        • INF4204.1: Rebel Multi-Connect Cable (5 Lead)
          • Rebel Data Logger Connector
          • CAN0/PWR Connector
          • AUX/CAN1 Connector
          • CAN 2/LIN 0 Connector
          • CAN 3/LIN 1 Connector
          • Digital & Analog Connector
        • INF4204.15: MOLEX – 5WAY DB9 SPLITTER CONNECTOR
        • INF4206: 180-degree OBD Type-B Cable to Rebel Data Logger Adapter cable
          • CAN/K-Line Connector
          • CAN/PWR/K-Line Connector
          • Power Connector (Banana)
        • INF4210: Rebel Dash Cable
          • Rebel Dash Connector
          • CAN/AUX Power Connector
        • INF4211: 25-way to 25-way D-sub shielded cable
        • INF4212.0: 9-way D-Sub screw terminal Male
        • INF4212.1: 9 way D-Sub screw terminal Female
        • INF4213: Multi-Connect digital and analog I/O terminal
        • INF4214: 25-way D-sub screw terminal Female
        • INF4216: ReXgen Air cable automotive connector to 25-way D-sub
          • 24-pin Molex Mini50 Connector
          • Male 25-pin Standard D Type connector
      • INF 43XX.XX
        • INF4300: Micro USB cable USB 2.0 A male to micro-B
        • INF4301: USB 2.0 A-B cable
        • INF4302: Rebel Digital Switch
          • DB15 Connector
        • INF4305.0: DB9 to DB9 Cable (Male to Female)
          • CAN Connector (Female 9)
          • CAN Connector (Male)
        • INF4305.1: DB9 to DB9 Cable (Male to Male)
          • Kvaser TCANnector Connector
          • K-Series CAN out Connector
        • INF4308C: 9-way to 9-way D-sub cable (Male to Female)
        • INF4310: D-Sub pin 120 Ohm termination adapter
    • ReXgen Series
      • ReXgen 1
      • ReXgen 2/IMU
      • ReXgen Air
    • Rebel Series
      • Rebel CT
        • The USB Connector
        • The OBD & INST Connector
        • The GPS Connector
        • The GPRS Connector
        • The WiFi Connector
        • The FlexRay/LIN & Can Ext Connector
      • Rebel LT
        • The USB Connector
        • The OBD & INST Connector
        • The GPS Connector
        • The GPRS Connector
    • K-Series
      • K-Box
      • K-AN8
      • KTC-XX
      • K-IEPE Pinouts (Add-On) (INF 2213) (Add-On)
      • K-PT
    • Rebel Dash
      • Pinout of the Rebel Dash Cable
      • Pinout of the OBD2 to DB9 Cable
      • Pinout of the Multi Connect Cable
    • Appendix 1
    • Appendix 2
    • Appendix 3
Powered by GitBook
On this page
  • The CAN Connectors (2x DB9 CAN Connectors)
  • The ADC Connector
  • The Thermocouple Connectors
Export as PDF
  1. Cables & Device Pinouts: Influx Product Range
  2. K-Series

K-Box

(INF 2201)

PreviousK-SeriesNextK-AN8

Last updated 9 months ago

The CAN Connectors (2x DB9 CAN Connectors)

The CAN Connectors are 1x Male and 1x Female 9-pin Standard D Type Connectors with nuts.

Pin No

Pin Function

Pin 1

Digital Output 4 or +4.5V Instrumentation Supply Voltage, ensure that current draw is not more than 100mA

Pin 2

CAN Bus Low Signal

Pin 3

Ground

Pin 4

Digital Input or Output 1 - Do not apply voltages outside of the 0 to +12V range when used as an input. When used as an Output, ensure that the current drawn is not more than 100mA. More information on the use of this pin can be found in Appendix 2 and 3

Pin 5

Power Ground

Pin 6

Digital Input or Output 3

Pin 7

CAN Bus High Signal

Pin 8

Digital Input or Output 2 - Do not apply voltages outside of the 0 to +12V range when used as an input. When used as an Output, ensure that the current drawn is not more than 100mA. More information on the use of this pin can be found in Appendix 2 and 3

Pin 9

4.5-36V Supply Voltage

WARNING:

  • Each End of the CAN bus must be terminated with a 120-ohm resistor across CAN H and CAN L.

The ADC Connector

The ADC Connector is a Male 25-pin Standard D-Type Connector with nuts.

Pin No

Pin Function

Pin 1

+24V Output - ensure that the current drawn is not more than 75mA

Pin 2

+5V Output - ensure that the current drawn is not more than 75mA

Pin 5

Analog Ground

Pin 6

Analog Input 0 + ve (do not apply voltages outside the voltage range the K-Box is configured for).

Pin 7

Analog Input 1 + ve (do not apply voltages outside the voltage range the K-Box is configured for).

Pin 8

Analog Input 2 + ve (do not apply voltages outside the voltage range the K-Box is configured for).

Pin 9

Analog Input 3 + ve (do not apply voltages outside the voltage range the K-Box is configured for).

Pin 10

Analog Input 4 + ve (do not apply voltages outside the voltage range the K-Box is configured for).

Pin 11

Analog Input 5 + ve (do not apply voltages outside the voltage range the K-Box is configured for).

Pin 12

Analog Input 6 + ve (do not apply voltages outside the voltage range the K-Box is configured for).

Pin 13

Analog Input 7 + ve (do not apply voltages outside the voltage range the K-Box is configured for).

Pin 14

Ground Out

Pin 15

Ground Out

Pin 17

Analog Ground

Pin 18

Analog Input 0 - ve (do not apply voltages outside the voltage range the K-Box is configured for).

Pin 19

Analog Input 1 - ve (do not apply voltages outside the voltage range the K-Box is configured for).

Pin 20

Analog Input 2 - ve (do not apply voltages outside the voltage range the K-Box is configured for).

Pin 21

Analog Input 3 - ve (do not apply voltages outside the voltage range the K-Box is configured for).

Pin 22

Analog Input 4 - ve (do not apply voltages outside the voltage range the K-Box is configured for).

Pin 23

Analog Input 5 - ve (do not apply voltages outside the voltage range the K-Box is configured for).

Pin 24

Analog Input 6 - ve (do not apply voltages outside the voltage range the K-Box is configured for).

Pin 25

Analog Input 7 - ve (do not apply voltages outside the voltage range the K-Box is configured for).

The Thermocouple Connectors

The Thermocouple Connectors on the K-Box are miniature-size flat-type sockets.

IEC Connector

Pin Function

Top

+ Signal from the Thermocouple

Bottom

K Signal from the Thermocouple

The dimensions of the Male Flat Type Miniature Size Thermocouple Plug that you would plug into it are as follows:

Note:

  • Pins not mentioned in the description table(s) are NC.

K-Box instrumentation device
Male 9-pin Standard D-Type Connector
Female 9-pin Standard D-Type Connector
Male 25-pin Standard D-Type Connector
Miniature-size flat-socket type thermocouple connectors
Dimensions of the Male Flat Type Miniature Size Thermocouple