LogoLogo
Home
  • DiaLog Software
  • DiaLog Software Manual
    • Introduction
      • Overview
      • Licence Agreement
      • Limitation of Liability
      • System Requirements
      • Software Versions
    • Getting Started
      • Software Installation
      • Software Introduction
        • Database Panel
        • Navigation Bar
          • Configuration Menu
          • Advanced Configuration Menu
          • Project Menu
          • Import Menu
          • Export Menu
          • Presets Menu
          • Logger Menu
          • Analysis Menu
          • StreamLog Menu
          • Settings Menu
        • Import Tabs
        • Main Panel
        • Message Panel
      • GPRS Settings
      • Wi-Fi Settings
      • Steps to Enable FIFO
      • How to obtain the diagnostic log before contacting support
  • Quick Start Guide
    • Set the Date and Time of the Rebel Data Logger.
    • Format the SD card of the Rebel Data Logger.
    • Reflash firmware of Rebel Data Logger.
    • View Live data using DaiLog
    • Manage projects in Dialog software
      • Create a new project
      • Export a project
      • Delete a project
      • Import a project
    • Create and manage a Configuration in Dialog Software
    • Configure Rebel data logger to record raw CAN messages
      • Record Raw CAN Bus data
      • Reconfigure the Rebel data logger
      • View Raw CAN data
    • Configuring Rebel Data Logger with DBC file
      • Log CAN signals using a DBC file
      • Reconfigure the rebel data logger.
    • Log data using an A2L file
      • Log data using an A2L file
      • Reconfigure the rebel data logger
    • Configuring Rebel Data Logger to record GNSS data
      • Creating a Configuration to Record GNSS data
      • Reconfigure the rebel data logger
    • Configure Analogue and Digital Inputs using DiaLog
      • Configure Analogue and Digital inputs in Dialog software using the rebel data logger
      • Reconfigure the rebel data logger
    • Using Digital Switch to Start Logging in a Rebel Logger
    • Exporting an IVD file
      • Extract an IVD file using the DiaLog software
      • Export an IVD file
    • Interpolate or resample while exporting data
    • Import DBC signals to multiple log data using Batch Processing
    • Merge multiple log data from existing IVD files
      • Method 1
      • Method 2
      • Method 3
    • Export CAN trace, EOBD, Statistical report and DTC data using BP
    • Extracting data around specific triggers using Batch Processing
    • Various methods for exporting CAN trace
      • Export Raw CAN trace from IVD files
      • Export CAN trace log by adding DBC signals
    • Configuring Rebel Dash in Dialog Software
      • Steps to Reconfigure the Rebel data logger and Rebel Dash
    • Export data from Dialog's Configurator version
    • Configure SD card/Rebel data logger using Dialog remote
      • Formatting the Sd card and sending the configuration to it
      • Using tabs in Dialog Remote
        • Set Rebel time
        • Settings
        • Reflash Rebel
    • Log data using UDS in DiaLog Software
    • Create a shell script for converting files
    • Deactivating and Moving the License of Dialog software
      • Deactivate the DiaLog license
      • Move a DiaLog license from one PC to another
  • Appendix 1
    • Reflash
    • Edit PID Presets
    • License Manager
    • General Option of Navigation bar, Settings Menu
    • Data Option of the Navigation bar, Settings Menu
    • Protocol Priorities
  • Appendix 2
    • Glossary
    • CAN Modes
    • CAN Definitions
    • Standard OBD Periodic Identifiers
  • Appendix 3
Powered by GitBook
On this page
  1. DiaLog Software Manual
  2. Introduction

Overview

The DiaLog software is a complete data logging environment, which becomes a very flexible and powerful solution when combined with a Rebel data logger. DiaLog combines full data logger configuration capabilities, a graphics and data analysis package*, several administration facilities, user-friendly graphical interfaces, and an intuitive layout. DiaLog provides an easy-to-use environment capable of configuring data loggers to record any combination of data, retrieve the recorded data by multiple direct and remote methods and finally analyse the recovered data or prepare it for import into external tools.

  • Construct complex data logger configurations for the most challenging applications using a simple graphical interface, allowing intuitive construction from individual components without scripting.

  • A simple and efficient database system allows easy configuration administration, supporting import and export features and simple component transferal between configurations.

  • Create complex Triggers with up to 30 conditions and 20 events with logic and formulaic application.

  • Write customisable user messages for transmission to a vehicle.

  • Conversion tables and formulae for instant scaling or feedback in engineering units.

  • Configurable output signals.

  • Supports multiple methods for data logger configuration, both directly and remotely.

  • Provides USB, Wi-Fi and GPRS connectivity*

  • Simple recorded data retrieval by direct or remote connection to the data logger.

  • Live connection to the Rebel while data logging allows personal control and live data feed.

  • Powerful Data Analysis suite boasts data scaling, multiple data plotting, XY scatter plots, dual cursors, and calculated channels, among many other features.

  • Supports all standard data formats for simple data import and transfer to alternative software packages.

  • 'Listen to only' mode logging allows recording the raw CAN data for up to 50 signals.

  • Perform and store complete EOBD/OBDII reports on trigger commands.

  • Convert and export multiple data files to select formats and create Data event reports for multiple triggers.

  • J1939 signal monitoring and DBC import.

PreviousIntroductionNextLicence Agreement

Last updated 1 year ago