Electrical Data

BUS & Signals

Operating Voltage

Power supply - OBD

+5V to+ 27V

Power supply - USB

+4.5 to +5.5V

CAN FD

+2 to +3V

LIN

0 to +24V

Digital Input

0 to +28V

Analog input

± 10V

FunctionDescription

ReXgen 2

ReXgen 2IMU

Transceiver Protection(CAN)

Bus fault protection: ±58 V

Thermal-shutdown protection (TSD)

Common mode input voltage: ± 12V

TXD dominant timeout (prevents network blocking in the event of a failure)

Under-voltage protection

Bus fault protection: ±58 V

Thermal-shutdown protection (TSD)

Common mode input voltage: ± 12V

TXD dominant timeout (prevents network blocking in the event of a failure)

Under-voltage protection

Transceiver Protection (LIN)

±8 kV HBM ESD, ±2 kV CDM, ± bus Fault

TXD dominant timeout (to prevent the LIN node from permanently driving the LIN Bus dominant)

±8 kV HBM ESD, ±2 kV CDM, ± bus Fault

TXD dominant timeout (to prevent the LIN node from permanently driving the LIN Bus dominant)

Power Voltage

5V for external sensor (current consumed should be less than 10mAmp)

5V for external sensor (current consumed should be less than 10mAmp)

Enclosure

PC+ ABS

PC+ ABS

IP Rating

IP65

IP65

Dimension

L - 100 mm, W - 73.5 mm, H – 27.4 mm

L - 100 mm, W - 73.5 mm, H – 27.4 mm

Weight

164 gms

164 gms

Mounting Holes

4 mounting holes and screws

4 mounting holes and screws

Stackable

Yes

Yes

Environmental Tolerance

Working temperature -40degC to +85degC; Humidity max 90%

Working temperature -40degC to +85degC; Humidity max 90%

Silent Mode

Listen only mode available (configurable Silent mode)

Listen only mode available (configurable Silent mode)

Power Saving

Wake Up On CAN, Wake up on Movement, Power Down Mode, Sleep Modes

Wake Up On CAN, Wake up on Movement, Power Down Mode, Sleep Modes

Power Safe

100% power safe data logging - no file corruption when disconnected or in sleep mode

100% power safe data logging - no file corruption when disconnected or in sleep mode

Protection

Reverse voltage protection on CAN-bus supply

Reverse voltage protection on CAN-bus supply

Power Consumption

Normal Operation: <75 mA at 12 V

Normal sleep <17mA

Deep Sleep <2 mA

Normal Operation: <80 mA at 12 V

Normal sleep <25mA

Deep Sleep <2 mA

* CEP - circular error probable

Last updated