Electrical Data
* CEP - circular error probable
Last updated
* CEP - circular error probable
Last updated
Function | Description | |
---|---|---|
BUS & Signals
Operating Voltage
Power supply - OBD
+5V to+ 27V
Power supply - USB
+4.5 to +5.5V
CAN FD
+2 to +3V
LIN
0 to +24V
Digital Input
0 to +28V
Analog input
± 10V
ReXgen 2
ReXgen 2IMU
Transceiver Protection(CAN)
Bus fault protection: ±58 V
Thermal-shutdown protection (TSD)
Common mode input voltage: ± 12V
TXD dominant timeout (prevents network blocking in the event of a failure)
Under-voltage protection
Bus fault protection: ±58 V
Thermal-shutdown protection (TSD)
Common mode input voltage: ± 12V
TXD dominant timeout (prevents network blocking in the event of a failure)
Under-voltage protection
Transceiver Protection (LIN)
±8 kV HBM ESD, ±2 kV CDM, ± bus Fault
TXD dominant timeout (to prevent the LIN node from permanently driving the LIN Bus dominant)
±8 kV HBM ESD, ±2 kV CDM, ± bus Fault
TXD dominant timeout (to prevent the LIN node from permanently driving the LIN Bus dominant)
Power Voltage
5V for external sensor (current consumed should be less than 10mAmp)
5V for external sensor (current consumed should be less than 10mAmp)
Enclosure
PC+ ABS
PC+ ABS
IP Rating
IP65
IP65
Dimension
L - 100 mm, W - 73.5 mm, H – 27.4 mm
L - 100 mm, W - 73.5 mm, H – 27.4 mm
Weight
164 gms
164 gms
Mounting Holes
4 mounting holes and screws
4 mounting holes and screws
Stackable
Yes
Yes
Environmental Tolerance
Working temperature -40degC to +85degC; Humidity max 90%
Working temperature -40degC to +85degC; Humidity max 90%
Silent Mode
Listen only mode available (configurable Silent mode)
Listen only mode available (configurable Silent mode)
Power Saving
Wake Up On CAN, Wake up on Movement, Power Down Mode, Sleep Modes
Wake Up On CAN, Wake up on Movement, Power Down Mode, Sleep Modes
Power Safe
100% power safe data logging - no file corruption when disconnected or in sleep mode
100% power safe data logging - no file corruption when disconnected or in sleep mode
Protection
Reverse voltage protection on CAN-bus supply
Reverse voltage protection on CAN-bus supply
Power Consumption
Normal Operation: <75 mA at 12 V
Normal sleep <17mA
Deep Sleep <2 mA
Normal Operation: <80 mA at 12 V
Normal sleep <25mA
Deep Sleep <2 mA