Gateway Routing CAN0 Signal to CAN1.
In this example, we will see how we can configure a ReXgen data logger to route all the CAN traffic from CAN 0 Bus to CAN 1 Bus
Documentation
The below image shows how each element is linked in the XML file.
They are connected using Unique IDs (UID).
Default Settings
CAN Baud Rate: 500 Kbps
All CAN IDs are Routed
The following parameters can be modified by editing the XML as required.
Modifying CAN Bus Channel:
Edit the value of the CANBusSpeed element in the XML file under the CAN interface block.
Value has to be specified in bps
Users can load the XML file into the ReXgen logger using the ReXdesk application/ReXdesk Convert application or the Rxlibrary DLL.
The process sends XML to the logger using ReXdesk. Click on Config Menu > Run > Run Config Using External File > Browse the XML file and click Open.