GNSS Data Recording & Transmission Over CAN Bus.
Last updated
Last updated
In this example, we will see how to configure a ReXgen data logger to transmit the GNSS positioning data over the CAN Bus and record the GNSS data in the internal storage.
Latitude Longitude Altitude Speed Over Ground Ground Distance Course Over Ground Number Of Satellites Quality
The image below shows how each element is linked in the XML file.
They are connected using Unique IDs (UID).
CAN Baud Rate: 500 Kbps
GNSS Sampling Rate: 100ms
CAN ID For various signals:
0x12B – Altitude, GPS Speed
0x12C – Longitude, Latitude
0x12D – Ground Distance
0x12E – Number Of Satellites, Course
0x12F - Quality
Example DBC provided with XML.
Modifying CAN Bus Channel:
Edit the value of the PhysicalNumber element in the XML file under the CAN interface block. 0 for CAN 0, 1 for CAN 1, 2 for CAN 2 and 3 for CAN 3
Modifying CAN Baud Rate:
Edit the value of the CANBusSpeed element in the XML file under the CAN interface block. Value has to be specified in bps
Modifying GNSS Sampling Rate:
Edit the value of the SamplingRate element under the GNSSINTERFACE Block
Value has to be specified in milliseconds
Modifying the CAN Identifier for the messages:
Edit the values of MessageIdentStart and MessageIdentEnd Elements under the CANMESSAGE block for the message you wish to edit. Please note that the example DBC will be invalid after this change.
Value has to be entered in Decimal
Modifying the CAN Message transmission period:
Edit the values of Period Elements under the CANMESSAGE block for the message you wish to edit.
Value has to be entered in milliseconds
The process to send XML to logger using ReXdesk. Click on Config Menu > Run > Run Config Using External File > Browse the XML file and click Open.
GitHub Link
XML file
DBC file