Page cover

K-Box: Product Manual

Introduction

The K-Box is Influx’s stackable instrumentation compatible with the ReXgen and Rebel range of data loggers. It can also be integrated with any device configured via DBC files, other logger systems, or output signals CAN to the Rebel Dash display.

The K-Box is an ideal solution for applications that require a large number of thermocouples and analog inputs. The K-Box’s accurate sensor data is transmitted periodically on the CAN bus, enabling multiple devices to be connected. The K-Box CAN bus settings, calibration, and sampling rates are all easily configurable, and these settings are stored within the K-Box even when the device is not powered.

Advantages:

  • Wide switchable software voltage input ranges ±80V, ±40V, ±20V or ±10V.

  • Accuracy: - Analog ±0.0015%, Thermocouples ±0.08%.

  • High input impedance.

  • They have isolated Differential Inputs to prevent earthing problems.

Key features:

  • Stackable enclosure.

  • Simple signal configuration using a DBC file.

  • Each unit enables up to 8 K-type connections at a 20Hz sampling rate and 8 analog inputs at a 1kHz sampling rate.

  • Pulse Width Measurement: 3 inputs frequency measurements or pulse measurements.

  • Regulated +5V and +12V output power supply for external sensors.

  • Instrumentation data time is synchronised with the recorded vehicle network data.

  • Analog inputs and thermocouple inputs are galvanically isolated.

  • Connect and measure data from up to 4 IEPE sensors using the K-IEPE addon.

  • Measure temperature using RTDs with K-PT100/1000 addon.

Technical Specification:

Technical Data
Description

Power supply

6V to 36V DC.

Interfaces

CAN Bus

PC interfaces

None

Enclosure

Dimension (L115xH79xW105) / Weight 450g / IP65 / ABS

Environmental

-40°C to +85°C Humidity max 90%

Output voltages

5V and 24V (Max current drawn 80 mA combined)

Analog Inputs

Number of channels

8 Bipolar differential inputs

Accuracy

±0.0015%

Software switchable range

±80V, ±40V, ±20V, ±10V

Resolution (ADC)

16 Bit

Max Sampling Rate

1 KHz (all 8 channels), 2 KHz (4Channels), 10 KHz (2 Channels)

Input impedance

> 4 M Ohm

Max input voltage

±75 Analog Ground, ±34V Analog inputs

Thermocouple Inputs

Number of channels

8 J/K/T-type inputs

Accuracy

±1°C accuracy

Measurement Range

Measurement: -200 °C to 1250 °C

Max Sampling Rate

10 Hz (all 8 channels)

Maximum input voltage

±3.3 V

Digital Input / Output

Number of channels

×4 unipolar single-ended hardware configured as inputs or outputs

Input switching thresholds

Low < 1.5V

High > 2.0V (up to 12V)

Input leakage current

< 10nA

Output states

(Optional) Open collector - 510 Ohm

Output drive capability (OK):

Collector-emitter voltage

45V max

Collector current (DC)

10mA max

Saturation voltage (OK on)

< 0.15V

Equivalent on-resistance

< 510Ohm

Leakage current at OK off

< 5uA

Min-max applied voltage

Digital input -8V to +12V; Digital output 0V to +40V power supply, which limits the current to 10mA

PWM

3 digital input frequency measurements up to 100kHz or pulse measurements. (min 100 Nano sec) (between pulses 10 microseconds)

Last updated