Loading...
Loading...
Loading...
Loading...
Loading...
Loading...
Loading...
Loading...
Loading...
Loading...
Loading...
Loading...
Loading...
Loading...
Loading...
Loading...
Loading...
Loading...
Loading...
Loading...
Loading...
Loading...
Loading...
Loading...
Loading...
Loading...
Loading...
Loading...
Loading...
Loading...
Loading...
Loading...
Loading...
Loading...
Loading...
Loading...
Loading...
Loading...
Loading...
Loading...
Loading...
Loading...
Loading...
Loading...
Loading...
Loading...
Loading...
Loading...
Loading...
Loading...
Loading...
Loading...
Loading...
Loading...
Loading...
Loading...
Loading...
Loading...
Loading...
Loading...
Loading...
Loading...
Loading...
Loading...
Loading...
Loading...
Loading...
Loading...
Loading...
Loading...
Loading...
Loading...
Loading...
Loading...
Loading...
Loading...
Loading...
Loading...
Loading...
Loading...
Loading...
Loading...
Loading...
Loading...
Loading...
Loading...
Cables
ReXgen Series
Rebel Series
K-Series
Rebel Dash
This cable is specifically designed to work with the Rebel 100, making it easier access the data loggerIO during the early engineering development stages.
The Rebel 100 is designed to be installed for long term event monitoring on production machinery and therefore the connector type is the same that you would normally find on an ECU. This type of connector is not very convenient for engineering development since these connectors are harder to work with. The Rebel100 start-up harness will enable you to connect to the Rebel 100 using standard9 PIN D-Sub connectors like the Rebel CT multi-connect cable.
Parameter
Value
Cable Length
890 mm
Cable Thickness
UNKNOWN
Connector A
Automotive Connectors ME ENCLOSURE CINCH 581-01-30-065
Connector B
9-pin D-sub (DB9) plug/nuts, pins compatible with CiA 303-1 (CAN0 and Power)
Connector C
9-pin D-sub (DB9) socket, pins compatible with CiA 303-1 (CAN 1)
Connector D
9-pin D-sub (DB9) socket, pins compatible with CiA 303-1 (CAN 2)
Connector E
9-pin D-sub (DB9) socket, pins compatible with CiA 303-1 (CAN 3)
Connector F
15 pin D-Sub (DB15) socket, digital and analog inputs
Temperature
Operating temperature: -20degC to +80degC (Start-up kit harness only)
Weight
469 g
Colour
Black
Data Logger Socket
CAN0/CAN1/Kline/PWR Connector
CAN 1 Connector
CAN 2 Connector
CAN 3 Connector
Digital and Analog Connector
Pin
Pin Function
Pin
Pin Function
Pin
Pin Function
1A
CAN 1-L
2A
CAN 1-H
3A
Dig0
1B
CAN 0-L
2B
CAN 0-H
3B
Dig1
1C
CAN 3-L
2C
CAN 3-H
3C
Dig2
1D
CAN 2-L
2D
CAN 2-H
3D
Dig3
1E
K-Line
2E
Wake-up#
3E
6-41V
1F
Erase#
2F
GND
3F
PowerGND
1G
Ain3_inst
2G
GNDa
3G
usb_+5V
1H
Ain2_inst
2H
GNDa
3H
usb_GND
1J
Ain1_inst
2J
GNDa
3J
usb_D+
1K
Ain0_inst
2K
GNDa
3K
usb_D-
Pin No
Pin Function
Pin 1
CAN Bus 1 (Medium Speed Bus) Low Signal
Pin 2
CAN Bus 0 (High Speed Bus) Low Signal
Pin 3
Ground
Pin 4
K-Line (1 wire bus) of ISO 9141
Pin 5
Power Ground
Pin 7
CAN Bus 0 (High Speed Bus) High Signal
Pin 8
CAN Bus 1 (Medium Speed Bus) High Signal
Pin 9
4.5-41V Supply Voltage
Pin No
Pin Function
Pin 2
CAN 3 Bus Low Signal
Pin 3
Power Ground
Pin 7
CAN 3 Bus High Signal
Pin No
Pin Function
Pin 2
Digital Input or Output 1 - When used as an input do not apply voltages outside of the 0 to +12V range, when used as an Output ensure that current draw is not more than 50mA.
More information on use of this pin can be found in Appendix 2 and 3
Pin 4
Ground
Pin 5
Erase
Pin 6
Analog Ground
Pin 7
Analog Input 1 - do not apply voltages outside of the -10 to +10V range
Pin 8
Analog Input 3 - do not apply voltages outside of the -10 to +10V range
Pin 9
Digital Input or Output 0 - When used as an input do not apply voltages outside of the 0 to +12V range, when used as an Output ensure that current draw is not more than 50mA.
More information on use of this pin can be found in Appendix 2 and 3-Normal
Pin 10
Digital Input or Output 2 - When used as an input do not apply voltages outside of the 0 to +12V range, when used as an Output ensure that current draw is not more than 50mA.
More information on use of this pin can be found in Appendix 2 and 3
Pin 11
Ground
Pin 13
Wake-Up pin to wake logger from sleep mode (for use see Appendix 1)
Pin 14
Analog Input 0 - do not apply voltages outside of the -10 to +10V range
Pin 15
Analog Input 2 - do not apply voltages outside of the -10 to +10V range
Pin No
Pin Function
Pin 2
CAN 2 Bus Low Signal
Pin 3
Power Ground
Pin 7
CAN 2 Bus High Signal
Pin No
Pin Function
Pin 6
CAN Bus 1 (Medium Speed Bus) Low Signal
Pin 7
CAN Bus 0 (High Speed Bus) Low Signal
Pin 8
K-Line (1 wire bus) of ISO 9141
Pin 9
4.5-36V Supply Voltage
Pin 19
CAN Bus 1 (Medium Speed Bus) High Signal
Pin 20
CAN Bus 0 (High Speed Bus) High Signal
Pin 21
Ground
Pin 22
Power Ground
Pin No
Pin Function
Pin 3
CAN Bus 1 (Medium Speed Bus) High Signal
Pin 4
Power Ground
Pin 5
Ground
Pin 6
CAN Bus 0 (High Speed Bus) High Signal
Pin 7
K-Line (1 wire bus) of ISO 9141
Pin 11
CAN Bus 1 (Medium Speed Bus) Low Signal
Pin 14
CAN Bus 0 (High Speed Bus) Low Signal
Pin 16
4.5-36V Supply Voltage
This 1.7-meter cable with 180-degree OBD2 Type B connector to 25 Way D-Sub connector (Female screw) enables you to connect Rebel LT and Rebel CT data loggers directly to the vehicle OBD port. Using this cable, the Rebel data logger is directly connected to the vehicle diagnostic CAN bus and also the vehicle permanent battery supply (please see the pin outs for more details). This cable is only recommended for use with the Rebel LT and Rebel CT data loggers.
Note that Type B can connect to type A port.
This 1.7-meter cable with 180-degree OBD2 Type B connector to 9 Way D-Sub connector (female screw) enables you to connect devices (CiA 303-1 compliant) to the vehicle OBD port.
To use this cable with a Rebel data logger you will also need one of our Rebel multi-connect breakout cables. This cable combination enables CAN 0 of the Rebel data logger to be directly connected to the vehicle diagnostic CAN bus and also the permanent battery supply.
INF4203: 2 CAN breakout cable (4 Lead)
INF4204.1: Multi-Connect Cable for Rebel data loggers (5 Lead)
This cable enables a direct connection from the ReXgen 9 Way D-Sub to the vehicle diagnostic
CAN bus and also the permanent battery supply.
This cable enables a direct connection from the Kvaser 9-Way D-Sub to the vehicle diagnostic CAN bus and battery supply.
Note that Type B can connect to type A port.
Parameter
Value
Cable Length
1700mm
Cable Thickness
22 AWG TBC
Connector A
25-pin D-sub (DB25) socket
Connector B
OBDII 16-pin connector
Temperature
Operating temperature: -20degC to +80degC
Weight
247 g
Colour
Black
Pin No
Pin Function
Pin 2
CAN Bus 0 (High Speed Bus) Low Signal
Pin 3
Ground
Pin 4
K-Line (1 wire bus) of ISO 9141
Pin 5
Power Ground
Pin 7
CAN Bus 0 (High Speed Bus) High Signal
Pin 9
4.5-36V Supply Voltage
Pin No
Pin Function
Pin 4
Power Ground
Pin 5
Ground
Pin 6
CAN Bus 0 (High Speed Bus) High Signal
Pin 7
K-Line (1 wire bus) of ISO 9141
Pin 14
CAN Bus 0 (High Speed Bus) Low Signal
Pin 16
4.5-36V Supply Voltage
Parameter
Value
Cable Length
1700mm
Cable Thickness
22 AWG TBC
DB9 Pins
In accordance with CiA 303 - 1
Connector A
9-pin D-sub (DB25) socket
Connector B
OBDII 16-pin connector
Operating temperature
-20degC to +80degC
Weight
236 g
Colour
Black
Pin No
Pin Function
Pin 2
FlexRay Bus 1 BM Signal
Pin 3
Ground for the FlexRay Buses
Pin 5
Power Ground
Pin 7
FlexRay Bus 1 BP Signal
Parameter
Value
Cable Length
700 mm
Cable Thickness
22 AWG 0.6 mm
Connector A
Micro D (DB15) socket, compatible with the Rebel CT FlexRay and RebelCT 7 dataloggers communication expansion port.
Connector B
9-pin D-sub (DB9) socket, pins compatible with CiA 303-1 (CAN 4 & LIN3)
Connector C
9-pin D-sub (DB9) socket, pins compatible with CiA 303-1 (CAN 5)
Connector D
9-pin D-sub (DB9) socket, pins compatible with CiA 303-1 (CAN 6)
Connector E
9-pin D-sub (DB9) plug, FleXray channel A
Connector F
9-pin D-sub (DB9) plug, FleXray channel B
Temperature
Operating temperature: -20degC to +80degC
Weight
236 g
Colour
Black
Expansion Port Connector
FlexRay 1 Connector
Flexray 2 Connector
CAN 4 and LIN 3 Connector
CAN 5 Connector
CAN 6 Connector
Pin No
Pin Function
Pin 1
CAN Bus 4 (Ext 1) Low Signal
Pin 2
CAN Bus 4 (Ext 1) High Signal
Pin 3
CAN Bus 5 (Ext 2) Low Signal
Pin 4
CAN Bus 5 (Ext 2) High Signal
Pin 5
CAN Bus 6 (Ext 3) Low Signal
Pin 6
CAN Bus 6 (Ext 3) High Signal
Pin 7
LIN (Local Interconnect Network) Bus
Pin 8
+Vin Supply Voltage
Pin 9
FlexRay Bus 1 BP Signal
Pin 10
FlexRay Bus 1 BM Signal
Pin 11
FlexRay Bus 2 BP Signal
Pin 12
FlexRay Bus 2 BM Signal
Pin 13
Ground for the FlexRay Buses
Pin 14
Ground for the CAN and LIN Buses
Pin 15
Power Ground
Pin No
Pin Function
Pin 2
FlexRay Bus 2 BM Signal
Pin 3
Ground for the FlexRay Buses
Pin 5
Power Ground
Pin 7
FlexRay Bus 2 BP Signal
Pin No | Pin Function |
Pin 2 | CAN Bus 4 (Ext 1) Low Signal |
Pin 3 | Ground for the CAN and LIN Buses |
Pin 4 | LIN 3 (Local Interconnect Network) Bus |
Pin 5 | Power Ground |
Pin 7 | CAN Bus 4 (Ext 1) High Signal |
Pin No
Pin Function
Pin 2
CAN Bus 5 (Ext 2) Low Signal
Pin 3
Ground for the CAN and LIN Buses
Pin 5
Power Ground
Pin 7
CAN Bus 5 (Ext 2) High Signal
This 230 mm breakout cable is supplied with each Rebel LT data logger making it suitable to connect devices that are compliant with the standard CIA 9-PIN D-Sub pinout directly to the data loggers.
The cable has one 25-Way D-Sub connector, which connects directly to the Rebel LT data logger and two 9-Way D-Sub connectors as described here:
POWER/CAN0 enables power and a CAN bus to be connected to the Rebel data logger. Type - 9-Way D-Sub (Plug)
AUX/CAN 1 enables a CAN bus to be connected to the Rebel data logger. This cable can also be used to supply auxiliary power from the Rebel data loggers to other devices that will be powered from the data logger. Type 9-Way D-Sub (Socket)
This cable is suitable for LT Data Loggers and can also be used to supply power directly to the K-series modules or the Rebel Dash from the Rebel data loggers. This helps to make the installation of our data loggers and instrumentation modules easy and with less cables required.
Parameter
Value
Cable Length
230mm
Cable Thickness
24 AWG 0.5 mm
Connector A
25-pin D-sub (DB25) socket, compatible with Rebel CT and Rebel LT data loggers
Connector B
9-pin D-sub (DB9) plug/nuts, pins compatible with CiA 303-1 (CAN 0 and Power)
Connector C
9-pin D-sub (DB9) socket, pins compatible with CiA 303-1 (CAN 1 and LIN)
Temperature
Operating temperature: -20degC to +80degC
Weight
142 g
Colour
Black
Pin No
Pin Function
Pin 2
CAN Bus 1 (Medium Speed Bus) Low Signal
Pin 3
Ground
Pin 5
Ground
Pin 6
Digital Input or Output 0 - When used as an input do not apply voltages outside of the 0 to +12V range, when used as an Output ensure that current draw is not more than 50mA.
More information on use of this pin can be found in Appendix 2 and 3
Pin 7
CAN Bus 1 (Medium Speed Bus) High Signal
Pin 9
Power Supply Switched
Pin No
Pin Function
Pin 5
Wake-Up pin to wake logger from sleep mode (for use see Appendix 1)
Pin 6
CAN Bus 1 (Medium Speed Bus) Low Signal
Pin 7
CAN Bus 0 (High Speed Bus) Low Signal
Pin 8
K-Line (1 wire bus) of ISO 9141
Pin 9
4.5-36V Supply Voltage
Pin 12
Digital Input or Output 0 - When used as an input do not apply voltages outside of the 0 to +12V range, when used as an Output ensure that current draw is not more than 50mA.
More information on use of this pin can be found in Appendix 2 and 3
Pin 19
CAN Bus 1 (Medium Speed Bus) High Signal
Pin 20
CAN Bus 0 (High Speed Bus) High Signal
Pin 21
Ground
Pin 22
Power Ground
Pin 23
Digital Input or Output 3 (can also be used as a switched power supply +Vd)
Female 25-pin standard D-Type connector with screws
Pin No
Pin Function
Pin 2
CAN Bus 0 (High Speed Bus) Low Signal
Pin 3
Ground
Pin 4
K-Line (1 wire bus) of ISO 9141
Pin 5
Power Ground
Pin 7
CAN Bus 0 (High Speed Bus) High Signal
Pin 9
4.5-36V Supply Voltage
Pin No | Pin Function |
Pin 1 | Analog Input 3 - do not apply voltages outside of the -10 to +10V range |
Pin 2 | LIN 1 |
Pin 3 | CAN/CAN FD 3 L |
Pin 4 | Analog Input 1 - do not apply voltages outside of the -10 to +10V range |
Pin 5 | Wake-Up pin to wake logger from sleep mode (for use see Appendix 1) |
Pin 6 | CAN Bus 1 (Medium Speed Bus) Low Signal |
Pin 7 | CAN Bus 0 (High Speed Bus) Low Signal |
Pin 8 | K-Line (1 wire bus) of ISO 9141 |
Pin 9 | 4.5-36V Supply Voltage |
Pin 10 | +4.5V Instrumentation Supply Voltage, ensure that current draw is not more than 100mA |
Pin 11 | Digital Input or Output 2 - When used as an input do not apply voltages outside of the 0 to +12V range, when used as an Output ensure that current draw is not more than 100mA. More information on use ofthis pin can be found in Appendix 2 and 3 |
Pin 12 | Digital Input or Output 0 - When used as an input do not apply voltages outside of the 0 to +12V range, when used as an Output ensure that current draw is not more than 100mA. More information on use ofthis pin can be found in Appendix 2 and 3 |
Pin 13 | CAN/CAN FD Bus 2 (Instrumentation Bus) Low Signal |
Pin 14 | Analog Input 2 - do not apply voltages outside of the -10 to +10V range |
Pin 15 | LIN 0 |
Pin 16 | CAN/CAN FD 3 H |
Pin 17 | Analog Input 0 - do not apply voltages outside of the -10 to +10V range |
Pin 18 | Analog Ground |
Pin 19 | CAN Bus 1 (Medium Speed Bus) High Signal |
Pin 20 | CAN Bus 0 (High Speed Bus) High Signal |
Pin 21 | Ground |
Pin 22 | Power Ground |
Pin 23 | Digital Input or Output 3 (can also be used as a switched power supply +Vd) |
Pin 24 | Digital Input or Output 1 - When used as an input do not apply voltages outside of the 0 to +12V range, when used as an Output ensure that current draw is not more than 100mA. More information on use ofthis pin can be found in Appendix 2 and 3 |
Pin 25 | CAN/CAN FD Bus 2 (Instrumentation Bus) High Signal |
This 230 mm breakout cable is supplied with each Rebel CT data logger making it suitable to connect devices that are compliant with the standard CIA 9-pin D-Sub pinout directly to our data loggers.
The cable has one 25-Way D-Sub connector, which connects directly to the Rebel CT data logger and four 9-Way D-Sub connectors to connect up to the separate CAN buses as described here:
POWER/CAN0 enables power and a CAN bus to be connected to the Rebel data logger. Type
- 9-Way D-Sub (Plug)
AUX/CAN 1 enables a CAN bus to be connected to the Rebel data logger and can be used to supply auxiliary power from the Rebel data loggers to other devices. Type -9-Way D-Sub (Socket)
CAN 2 Type - 9-Way D-Sub (Socket)
CAN 3 Type - 9-Way D-Sub (Socket)
Additionally, a 15-Way D-Sub (Socket) connector enables easy connection to the data logger analog and digital pins.
Parameter
Value
Cable Length
230mm
Cable Thickness
24 AWG 0.5 mm
Connector A
25-pin D-sub (DB25) socket, compatible with Rebel CT and Rebel LT data loggers
Connector B
9-pin D-sub (DB9) plug/nuts, pins compatible with CiA 303-1 (CAN0 and Power)
Connector C
9-pin D-sub (DB9) socket, pins compatible with CiA 303-1 (CAN 1)
Connector D
9-pin D-sub (DB9) socket, pins compatible with CiA 303-1 (CAN 2)
Connector E
9-pin D-sub (DB9) socket, pins compatible with CiA 303-1 (CAN 3)
Connector F
15-pin D-sub (DB15) socket, digital and analog inputs
Temperature
Operating temperature: -20degC to +80degC
Weight
263 g
Colour
Black
Pin No | Pin Function |
Pin 2 | CAN Bus 1 (Medium Speed Bus) Low Signal |
Pin 3 | Ground |
Pin 5 | Power Ground |
Pin 7 | CAN Bus 1 (Medium Speed Bus) High Signal |
Pin 9 | Power Supply Switched |
Pin No
Pin Function
Pin 1
CAN Bus 1 (Medium Speed Bus) Low Signal
Pin 2
CAN Bus 0 (High Speed Bus) Low Signal
Pin 3
Ground
Pin 4
K-Line (1 wire bus) of ISO 9141
Pin 5
Power Ground
Pin 7
CAN Bus 0 (High Speed Bus) High Signal
Pin 8
CAN Bus 1 (Medium Speed Bus) High Signal
Pin 9
4.5-36V Supply Voltage
Pin No | Pin Function |
Pin 1 | LIN 1 |
Pin 2 | CAN CAN FD Bus 3 (Instrumentation Bus) Low Signal |
Pin 3 | Ground |
Pin 5 | Power Ground |
Pin 7 | CAN/CAN FD Bus 3 (Instrumentation Bus) High Signal |
Pin 9 | Digital Input or Output 3 (can also be used as a switched power supply +Vd). When used as an input do not apply voltages outside of the 0 to +12V range |
Pin No
Pin Function
Pin 1
LIN 0
Pin 2
CAN/CAN FD Bus 2 (Instrumentation Bus) Low Signal
Pin 3
Ground
Pin 5
Power Ground
Pin 7
CAN/CAN FD Bus 2 (Instrumentation Bus) High Signal
Pin 9
Digital Input or Output 3 (can also be used as a switched power supply +Vd). When used as an input do not apply voltages outside of the 0 to +12V range
Pin No | Pin Function |
Pin 2 | Digital Input or Output 1 - When used as an input do not apply voltages outside of the 0 to +12V range, when used as an Output ensure that current draw is not more than 100mA. More information on use of this pin can be found in Appendix 2 and 3 |
Pin 3 | +4.5V Instrumentation Supply Voltage, ensure that current draw is not more than 100mA |
Pin 4 | Ground |
Pin 6 | Analog Ground |
Pin 7 | Analog Input 1 - do not apply voltages outside of the -10 to +10V range |
Pin 8 | Analog Input 3 - do not apply voltages outside of the -10 to +10V range |
Pin 9 | Digital Input or Output 0 - When used as an input do not apply voltages outside of the 0 to +12V range, when used as an Output ensure that current draw is not more than 100mA. More information on use of this pin can be found in Appendix 2 and 3 |
Pin 10 | Digital Input or Output 2 - When used as an input do not apply voltages outside of the 0 to +12V range, when used as an Output ensure that current draw is not more than 100mA. More information on use of this pin can be found in Appendix 2 and 3 |
Pin 11 | Ground |
Pin 13 | Wake-Up pin to wake logger from sleep mode (for use see Appendix 1) |
Pin 14 | Analog Input 0 - do not apply voltages outside of the -10 to +10V range |
Pin 15 | Analog Input 2 - do not apply voltages outside of the -10 to +10V range |
Parameter | Value |
Cable Length | 1500mm |
Cable Thickness | 24 AWG 0.5 mm |
Connector A | Connects to Rebel Dash, Deutsch connector 12-way |
Connector B | 9-pin D-sub [DB9] plug, compatible with CiA 303-1 |
Temperature | Operating temperature: -20degC to +80degC |
Weight | 122 g |
Colour | Black |
Pin No | Pin Function |
Pin 2 | CAN Bus Low Signal |
Pin 3 | Ground |
Pin 4 | K-Line |
Pin 5 | Power Ground |
Pin 7 | CAN Bus High Signal |
Pin 9 | Power Supply 4.5 – 36 V |
This cable is ideal if you require power to a K-Series devices or Rebel data logger without the usual access to the OBD port. Simply use either the vehicle auxiliary power outlet or banana plugs (battery) for the power supply.
Connector A, is a 9 Way D-Sub (Socket) connected to power from either a vehicle auxiliary power outlet (cigar lighter) OR banana plugs and the CAN bus (PIN 2 &7) Connector B, is a 9 Way D-Sub (Plug) connected to the CAN bus (PIN 2 & 7).
Parameter
Value
Cable Length
230mm
Cable Thickness
26 AWG 0.4 mm
Connector A
9-pin D-sub (DB9) plug [nuts], pins compatible with CiA 303-1 (CAN
and Power)
Connector B
9-pin D-sub (DB9) socket [screw], pins compatible with CiA 303-1 (CAN only)
AUX Socket
Power with LED
Banana +
Power (+)
Banana -
Power (-)
Connector F
9-pin D-sub (DB9) plug, FleXray channel B
Temperature
Operating temperature: -20degC to +80degC
Weight
219 g
Colour
Black
CAN/K-Line Connector
CAN/PWR/K-Line Connector
Power Connector (Banana)
Pin No
Pin Function
Pin 2
CAN Bus Low Signal
Pin 3
Ground
Pin 4
K-Line (1 wire bus) of ISO 9141
Pin 7
CAN Bus High Signal
The Power Connector is Red and Black Banana Connector.
Pin No
Pin Function
Red
Power Supply 4.5 – 36 V
Black
Power Ground
Pin No | Pin Function |
Pin 1 | Power Ground |
Pin 2 | Power Supply 10 to 32 V |
Pin 4 | Ground |
Pin 7 | CAN Bus Low Signal |
Pin 8 | CAN Bus High Signal |
Parameter
Value
Cable Length
200mm
Cable Thickness
21 AWG 0.7 mm
Connections
Fully pinned direct pin to pin, shielded
Connector A
25 pin D-Sub (DB25) socket
Connector B
25 pin D-Sub (DB25) plug
Type
Screw terminal
Weight
148 g
Colour
Black
Parameter
Value
No of Pins
15
Gender
Male (Plug)
Connector A
15 pin D-Sub (DB15) plug
Temperature
Operating temperature: -20degC to +80N.degC
Type
Screw terminal
Weight
30g
Parameter
Value
No of Pins
15
Gender
Male (Plug)
Connector A
15 pin D-Sub (DB15) plug
Temperature
Operating temperature: -20degC to +80degC
Type
Screw terminal
Weight
45g
Parameter
Value
No Of Pins
25
Gender
Female (Socket)
Connector A
25 pin D-Sub (DB15) socket
Temperature
Operating temperature: -20degC to +80degC
Type
Screw terminal
Weight
75g
Parameter
Value
No of Pins
9
Gender
Female (Socket)
Connector A
9 pin D-Sub (DB15) socket
Temperature
Operating temperature: -20degC to +80degC
Type
Screw terminal
Weight
30g
Parameter
Value
Cable Length
250mm
Cable Thickness
22AWG
Connector A
Male 25-pin Standard D Type connector
Connector B
24-pin Molex Mini50 connector
Colour
Black
PIN No | PIN Function | Optional |
Pin 1 | RelayOut0 | Relay Driver |
Pin 2 | DigIn0 |
|
Pin 3 | AnalogGnd |
|
Pin 4 | Adc1 |
|
Pin 5 | Clamp-15 |
|
Pin 6 | CAN0-L |
|
Pin 7 | CAN1-L |
|
Pin 8 | CAN2-L | Additional CAN FD 3rd bus |
Pin 9 | CAN3-L | Additional CAN FD 4th bus |
Pin 10 | usbDP_conn | Request when ordering |
Pin 11 | 4.5Vout |
|
Pin 12 | DIgIn1 |
|
Pin 13 | Adc0 |
|
Pin 14 | Erase# |
|
Pin 15 | LIN |
|
Pin 16 | GND |
|
Pin 17 | PowerGND |
|
Pin 18 | 5V to 27V |
|
Pin 19 | CAN0-H |
|
Pin 20 | CAN1-H |
|
Pin 21 | CAN2-H | Additional CAN FD 3rd bus |
Pin 22 | CAN3-H | Additional CAN FD 4th bus |
Pin 23 | usb5V | Request when ordering |
Pin 24 | usbDM_conn | Request when ordering |
(Mini 50 to D Sub 25 cable Sold separately).
Pin No
Pin Function
Pin 3
CAN Bus 3 Low Signal (Available only on 4x CAN Model)
Pin 4
Analog Input 1 - do not apply voltages outside of the -10 to +10V range
Pin 5
Wake-Up pin to wake logger from sleep mode (Appendix 1)
Pin 6
CAN Bus 1 Low Signal
Pin 7
CAN Bus 0 Low Signal
Pin 9
+5V to +27V Supply Voltage
Pin 10
+4.5V Instrumentation Supply Voltage, ensure that current draw is not more than 100mA
Pin 11
Erase PIN
Pin 12
Digital Input 0 - When used as an input, do not apply voltages outside the 0 to +12V range.
More information on the use of this pin can be found in Appendix 2
Pin 13
CAN Bus 2 Low Signal (Available only on 4x CAN Model)
Pin 15
LIN 0 Signal
Pin 16
CAN Bus 3 High Signal (Available only on 4x CAN Model)
Pin 17
Analog Input 0 - do not apply voltages outside of the -10 to +10V range
Pin 18
Analog Ground
Pin 19
CAN Bus 1 High Signal
Pin 20
CAN Bus 0 High Signal
Pin 21
Ground
Pin 22
Power Ground
Pin 23
Relay Out (Optional Feature)
Pin 24
Digital Input 1 - When used as input, do not apply voltages outside the 0 to +12V range
More information on the use of this pin can be found in Appendix 2
PIN 25
CAN Bus 2 High Signal (Available only on 4x CAN Model)
Parameter
Value
Cable Length
914 mm
Parameter
Value
Cable Length
914mm
Cable Thickness
26 AWG 0.4 mm
Connector A
USB 2.0 A
Connector B
USB 2.0 B
Temperature
Operating temperature: -20degC to +80degC
Weight
35 g
Colour
Black
Pin No
Pin Function
Pin 4
Shields
Pin 9
S1 Light Blue
Pin 11
S1 Black
Pin No
Pin Function
C
Ground/Shield
NO
Vid+
NC
Vid-
Pin No
Pin Function
Pin 2
CAN Low Signal
Pin 3
Ground
Pin 5
Power Ground
Pin 7
CAN High Signal
Pin 9
Power Supply 4.5 – 36 V
Pin No
Pin Function
Pin 2
CAN Low Signal
Pin 3
Ground
Pin 5
Power Ground
Pin 7
CAN High Signal
Pin 9
Power Supply 4.5 – 36 V
Parameter
Value
Cable Length
300mm
Cable Thickness
5.75mm
Connector A
9 pin D-Sub (DB9) plug [nut]
Connector B
9 pin D-Sub (DB9) plug [screw]
Temperature
Operating temperature: -20degC to +80degC
Weight
UNKNOWN
Colour
Black
Parameter
Value
No of Pins
300mm
Cable Thickness
24 AWG 0.5 mm
Connector A
V
Type
9 pin D-Sub (DB9) plug [screw], pins compatible with CiA 303-1 (CAN and Power)
Temperature
Operating temperature: -20degC to +80degC
Weight
68 g
Colour
Black
Pin No
Pin Function
Pin 2
CAN Low Signal
Pin 3
Ground
Pin 5
Power Ground
Pin 7
CAN High Signal
Pin 9
Power Supply 4.5 – 36 V
Kvaser TCANnector Connector
K-Series CAN out Connector
CAN Connector (Female 9)
CAN Connector (Male)
Pin No
Pin Function
Pin 2
CAN Low Signal
Pin 3
Ground
Pin 5
Power Ground
Pin 7
CAN High Signal
Pin 9
Power Supply 4.5 – 36 V
Influx branded 120 Ohm termination adapter.
Highly recommended to terminate the CAN bus on the K-Series.
Parameter
Value
Cable Length
500mm
Cable Thickness
5.75mm
Connections
Fully pinned direct pin to pin
Connector A
9 pin D-Sub (DB9) [plug][nuts], fully pinned
Connector B
9 pin D-Sub (DB9) [socket][screw], fully pinned
Temperature
Operating temperature: -20degC to +80degC
Weight
UNKNOWN
Colour
Black
There is one 9-pin Standard D-Type connector.
Pin No
Pin Function
Pin 1
NC
Pin 2
CAN-Low
Pin 3
GND
Pin 4
Nc
Pin 5
Power GND
Pin 6
NC
Pin 7
CAN-High
Pin 9
Power Supply 5V to 27V
There are two connectors, a 24-pin Molex Mini50 connector and a male 25-pin Standard D Type connector
PIN No
PIN Function
Optional
Pin 1
RelayOut0
Relay Driver
Pin 2
DigIn0
Pin 3
AnalogGnd
Pin 4
Adc1
Pin 5
Clamp-15
Pin 6
CAN0-L
Pin 7
CAN1-L
Pin 8
CAN2-L
Additional CAN FD 3rd bus
Pin 9
CAN3-L
Additional CAN FD 4th bus
Pin 10
usbDP_conn
Request when ordering
Pin 11
4.5Vout
Pin 12
DIgIn1
Pin 13
Adc0
Pin 14
Erase#
Pin 15
LIN
Pin 16
GND
Pin 17
PowerGND
Pin 18
5V to 27V
Pin 19
CAN0-H
Pin 20
CAN1-H
Pin 21
CAN2-H
Additional CAN FD 3rd bus
Pin 22
CAN3-H
Additional CAN FD 4th bus
Pin 23
usb5V
Request when ordering
Pin 24
usbDM_conn
Request when ordering
Pin No
Pin Function
Pin 3
CAN Bus 3 Low Signal (Available only on 4x CAN Model)
Pin 4
Analog Input 1 - do not apply voltages outside of the -10 to +10V range
Pin 5
Wake-Up pin to wake logger from sleep mode (Appendix 1)
Pin 6
CAN Bus 1 Low Signal
Pin 7
CAN Bus 0 Low Signal
Pin 9
+5V to +27V Supply Voltage
Pin 10
+4.5V Instrumentation Supply Voltage, ensure that current draw is not more than 100mA
Pin 11
Erase PIN
Pin 12
Digital Input 0 - When used as an input, do not apply voltages outside the 0 to +12V range.
More information on the use of this pin can be found in Appendix 2
Pin 13
CAN Bus 2 Low Signal (Available only on 4x CAN Model)
Pin 15
LIN 0 Signal
Pin 16
CAN Bus 3 High Signal (Available only on 4x CAN Model)
Pin 17
Analog Input 0 - do not apply voltages outside of the -10 to +10V range
Pin 18
Analog Ground
Pin 19
CAN Bus 1 High Signal
Pin 20
CAN Bus 0 High Signal
Pin 21
Ground
Pin 22
Power Ground
Pin 23
Relay Out (Optional Feature)
Pin 24
Digital Input 1 - When used as input, do not apply voltages outside the 0 to +12V range
More information on the use of this pin can be found in Appendix 2
PIN 25
CAN Bus 2 High Signal (Available only on 4x CAN Model)
PCB Header
Mating Connector Details
Terminals
There are two connectors, a male and female 9-pin Standard D Type connector.
Pin No | Pin Function |
Pin 1 | Digital 1 |
Pin 2 | CAN 0 – Low |
Pin 3 | GND |
Pin 4 | LIN |
Pin 5 | Power GND |
Pin 6 | Digital 0 |
Pin 7 | CAN 0 – High |
Pin 9 | Power Supply 5V to 27V |
Pin No | Pin Function |
Pin 1 | GND A |
Pin 2 | CAN 1 – Low |
Pin 3 | GND |
Pin 4 | Analog IN 0 |
Pin 5 | GND A |
Pin 6 | Analog IN 1 |
Pin 7 | CAN 1 – High |
Pin 8 | Clamp-15 |
Bus and signals | Operating voltage | Safe applied voltage |
Power supply - OBD | +5V to +27V | ±34V |
Power supply - USB | +4.5V to +5.5V | 0V to +6V |
CAN/CAN FD | +2V to +3V | ± 28V |
ANALOGUE Input | ± 10 V | ± 28V |
DIGITAL INPUT | LOW < +0.8 V HIGH > 2.5 V | ± 28V |
Pin No
Pin Function
Pin 1
VBUS USB supply voltage 5V
Pin 2
Data- line of USB, this signal utilises NRZI line coding
Pin 3
Data+ line of USB, this signal utilises NRZI line coding
Pin 4
Ground
The OBD & INST Connector is a Male 25-pin Standard D Type Connector with nuts.
Pin No
Pin Function
Pin 1
Analog Input 3- do not apply voltage outside of the -10 to +10 V range
Pin 2
LIN 1
Pin 3
CAN / CAN FD Bus 3 Low signal
Pin 4
Analog Input 1 - do not apply voltages outside of the -10 to +10V range
Pin 5
Wake-Up pin to wake logger from sleep mode (for use, see Appendix 1)
Pin 6
CAN Bus 1 (Medium Speed Bus) Low Signal
Pin 7
CAN Bus 0 (High-Speed Bus) Low Signal
Pin 8
NC
Pin 9
4.5-36V Supply Voltage
Pin 10
+4.5V Instrumentation Supply Voltage, ensure that the current drawn is not more than 100mA
Pin 11
Digital Input or Output 2 - Do not apply voltages outside of the 0 to +12V range when used as an input. When used as an Output, ensure that the current drawn is not more than 100mA.
More information on the use of this pin can be found in Appendix 2 and 3
Pin 12
Digital Input or Output 0 - Do not apply voltages outside the 0 to +12V range when used as an input. When used as an Output, ensure that the current drawn is not more than 100mA.
More information on the use of this pin can be found in Appendix 2 and 3
Pin 13
CAN /CAN FD Bus 2 (Instrumentation Bus) Low Signal
Pin 14
Analog Input 2 - - do not apply voltages outside of the -10 to +10V range
Pin 15
LIN 0
Pin 16
CAN / CAN FD Bus 3 High signal
Pin 17
Analog Input 0 - - do not apply voltages outside of the -10 to +10V range
Pin 18
Analog Ground
Pin 19
CAN Bus 1 (Medium Speed Bus) High Signal
Pin 20
CAN Bus 0 (High-Speed Bus) High Signal
Pin 21
Ground - e.g. to be connected to pin 5 of the OBDII Connector
Pin 22
Power Ground - e.g. to be connected to pin 4 of the OBDII Connector
Pin 23
Digital Input or Output 3 (can also be used as a switched power supply +Vd). Do not apply voltages outside of the 0 to +12V range when used as an input.
Pin 24
Digital Input or Output 1 - Do not apply voltages outside of the 0 to +12V range when used as an input. When used as an Output, ensure that the current drawn is not more than 100mA.
More information on the use of this pin can be found in Appendix 2 and 3
Pin 25
CAN / CAN FD Bus 2 (Instrumentation Bus) High Signal
The Optional GPS Connector is a Male SMB Connector.
Pin No
Pin Function
Pin 1
Radio Frequency Signal Input
Pin 2
Ground
The Optional GPRS Connector is a Male RP-SMA Connector.
Pin No
Pin Function
Pin 1
Radio Frequency Signal Input
Pin 2
Ground
The Optional WiFi Connector is a Female RP-SMA Connector.
Pin No
Pin Function
Pin 1
Radio Frequency Signal Input
Pin 2
Ground
Pin No
Pin Function
Pin 1
CAN Bus 4 (Ext 1) Low Signal
Pin 2
CAN Bus 4 (Ext 1) High Signal
Pin 3
CAN Bus 5 (Ext 2) Low Signal
Pin 4
CAN Bus 5 (Ext 2) High Signal
Pin 5
CAN Bus 6 (Ext 3) Low Signal
Pin 6
CAN Bus 6 (Ext 3) High Signal
Pin 7
LIN (Local Interconnect Network) Bus
Pin 8
+Vin Supply Voltage
Pin 9
FlexRay Bus 1 BP Signal
Pin 10
FlexRay Bus 1 BM Signal
Pin 11
FlexRay Bus 2 BP Signal
Pin 12
FlexRay Bus 2 BM Signal
Pin 13
Ground for the FlexRay Buses
Pin 14
Ground for the CAN and LIN Buses
Pin 15
Power Ground
The Rebel LT (RC5-2) (INF 2101)
The Optional GPS Connector is a Male SMB Connector.
Pin No
Pin Function
Pin 1
Radio Frequency Signal Input
Pin 2
Ground
The USB Connector is a USB Series “B” Receptacle Interface.
The OBD & INST Connector is a Male 25-pin Standard D Type Connector nut.
Pin No
Pin Function
Pin 1
VBUS USB supply voltage 5V
Pin 2
Data- line of USB this signal utilises NRZI line coding
Pin 3
Data+ line of USB this signal utilises NRZI line coding
Pin 4
Ground
Pin No
Pin Function
Pin 1
Analog Input 3 - do not apply voltages outside of the -10 to +10V range
Pin 2
NC
Pin 3
NC
Pin 4
Analog Input 1 - do not apply voltages outside of the -10 to +10V range
Pin 5
Wake-Up pin to wake logger from sleep mode (for use, see Appendix 1)
Pin 6
CAN Bus 1 (Medium Speed Bus) Low Signal
Pin 7
CAN Bus 0 (High-Speed Bus) Low Signal
Pin 8
K-Line (1 wire bus) of ISO 9141
Pin 9
4.5-36V Supply Voltage
Pin 10
+4.5V Instrumentation Supply Voltage, ensure that the current drawn is not more than 100mA
Pin 11
Digital Input or Output 2 - Do not apply voltages outside of the 0 to +12V range when used as an input. When used as an Output, ensure that the current drawn is not more than 100mA.
More information on the use of this pin can be found in Appendix 2 and 3
Pin 12
Digital Input or Output 0 - Do not apply voltages outside the 0 to +12V range when used as an input. When used as an Output, ensure that the current draw is not more than 100mA.
More information on the use of this pin can be found in Appendix 2 and 3
Pin 13
NC
Pin 14
Analog Input 2 - do not apply voltages outside of the -10 to +10V range
Pin 15
NC
Pin 16
NC
Pin 17
Analog Input 0 - do not apply voltages outside of the -10 to +10V range
Pin 18
Analog Ground
Pin 19
CAN Bus 1 (Medium Speed Bus) High Signal
Pin 20
CAN Bus 0 (High-Speed Bus) High Signal
Pin 21
Ground
Pin 22
Power Ground
Pin 23
Digital Input or Output 3 (can also be used as a switched power supply +Vd). When used as an input, do not apply voltages outside of the 0 to +12V range
Pin 24
Digital Input or Output 1 - Do not apply voltages outside of the 0 to +12V range when used as an input. When used as an Output, ensure that the current drawn is not more than 100mA.
More information on the use of this pin can be found in Appendix 2 and 3
Pin 25
NC
Pin No
Pin Function
Pin 2
CAN Bus 1 (Medium Speed Bus) Low Signal
Pin 3
Ground
Pin 5
Ground
Pin 7
CAN Bus 1 (Medium Speed Bus) High Signal
Pin No
Pin Function
Pin 2
CAN Bus 6 (Ext 3) Low Signal
Pin 3
Ground for the CAN and LIN Buses
Pin 5
Power Ground
Pin 7
CAN Bus 6 (Ext 3) High Signal
Parameter
Value
Cable Length
1800 mm
Cable Thickness
26 AWG 0.4 mm
Connector A
15-pin D-sub (DB15) Male
Switch
UNKNOWN
Temperature
Operating temperature: -20degC to +80degC
Weight
116 g
Colour
Black
DB15 Connector
DB9 Pins
Pin Function
Pin 2
CAN Bus Low Signal
Pin 3
Ground (alternatively pin 5 may be used)
Pin 5
Ground (alternatively pin 3 may be used)
Pin 7
CAN Bus High Signal
Pin 9
Power Supply 10-32V
The Optional GPRS Connector is a Male RP-SMA Connector.
Pin No
Pin Function
Pin 1
Radio Frequency Signal Input
Pin 2
Ground
INF4202: Rebel FlexRay/CAN Breakout Cable
INF4203: Rebel LT CAN Bus Breakout Cable
INF4204.1: Rebel Multi-Connect Cable (5 Lead)
INF4206: 180-degree OBD Type-B Cable to Rebel Data Logger Adapter cable
INF4210: Rebel Dash Cable
INF4211: 25-way to 25-way D-sub shielded cable
INF4212.0: 9-way D-Sub screw terminal Male
INF4212.1: 9 way D-Sub screw terminal Female
INF4213: Multi-Connect digital and analog I/O terminal
INF4214: 25-way D-sub screw terminal Female
INF4216: ReXgen Air cable automotive connector to 25 way D-sub