ReXgen Air
INF2116.NN - Hardware Configurable (Up to 32 GB)
Last updated
INF2116.NN - Hardware Configurable (Up to 32 GB)
Last updated
ReXgen Air is a compact, robust, accurate and cost-effective solution designed to become part of your fleet during production.
This is a progressive system that works on LTE CAT1. A data logger with onboard processing and telematics capabilities connects machines to the cloud or stores data locally.
Allows the encryption of data logs with the Secure Hash Algorithm (SHA).
An open platform that can be supported by any third-party tools and integrated into any data system. It is supplied with a free, powerful graphic interface application tool.
ReXgen Air allows you to build your system to maintain your data.
Up to 4 CAN/CAN FD buses
x1 LIN bus
x2 Analog Inputs, x2 Digital inputs & x1 Power Stage Relay Driver (Optional)
Integrated 18Hz GNSS (u-Blox) and IMU (6 axis)
Encrypts data logs using Advanced Encryption Standard (AES)
Open API or XML Schema provided
Live CAN/CAN FD trace Monitoring
Enables Locking of the device using RSA data security
Micro USB 2.0 for data transfer and configuration
CAT -1 connectivity
Secure Data transfer using FTPs and Amazon S3
Supported Data formats -ASAM MDF4 MATLAB (.mat), CSV, ASC, BLF & TRC
Various sleep modes with low power consumption
x4 configurable LEDs
CAN/J1939 filters
Easily stackable and installable
Automotive grade Molex Mini50 connection system
CAN Interfaces
Up to 4 x CAN/CAN FD
ISO 11898-1: Compliant with CAN (up to 1 Mbit/s)
ISO & Bosch CAN FD (up to 8 Mbit/s)
Conforms to CAN protocol version 2.0 - part A, B
Up to 20000 mps
Meets the requirements of ISO 11898-2:2016 & ISO 11898-5:2007 physical layer standards
CAN/CAN FD Functions
CAN/CAN FD Bit timing selection
SAE J1939 support (Source Address, Destination Address & PGN Filters)
Silent Mode Configurable Periodic CAN Transmission CAN DBC Support
CAN frame error detection
Identifiers
Compliant with CAN specifications 2.0A (11-Bit ID) and 2.0B (29-Bit ID)
CAN Error Frames
Support for logging CAN error frames (bit-stuffing, form, CRC, bit, acknowledgement)
Retransmission
Configurable retransmission of frames that have lost arbitration or been disturbed by errors
Prescaling
Pre-scale CAN frames to record e.g., by time (per X ms) or by data (e.g., if byte X or Y changes)
Transmit
Transmit lists of CAN frames per channel (periodic) - e.g., for OBD2 requests- Capability to link multiple CAN messages
LIN Interface
1 x LIN (Master & Slave mode)
Compliant with LIN Bus Specifications 1.3, 2.0 and 2.1 and are compliant to SAE J2602
LIN channel can be configured as a LIN subscriber/publisher with support for LIN data transmission
Support for custom frame lengths
Parallel CAN/LIN
Record data from up to upto 4 x CAN channels + 1 x LIN channels, simultaneously
Connector
Molex Mini50 Dual Row 24 Pin connector (enables the device to be easily and robustly installed in production machines)
LTE
CAT 1 (see uBlox Lara R2 Series)/Quectel CAT 4
Inputs
2 x Digital and 2 x Analog
Bit-Rate Auto-Detect
Bit rate can be auto-detected or set manually
Instrumentation Supply
5 Volts (Ensure that current draw is not more than 100mA)
Real-Time Clock
Yes - CAN frames are date & timestamped with 10 microsecond resolution (battery backup)
The RTC can be configured to match local time zones (default: UTC)
The RTC can be auto-synced via 3G/4G LTE Timestamp or a CAN message (e.g., from the internal GNSS timestamp)
File Split
Configurable log file split size (by size: 10-500 MB and/or by time period)
Unique Device ID
Each device has a globally unique ID ensuring unique log file naming
Signed Firmware
Firmware updates are digitally signed to verify that they are from a trusted source
Cyclic Logging
Enabled by default
Positioning Sensors
GNSS Module
M8U-30 Hz (supports dead reckoning) / M8Q-18Hz (does not support dead reckoning) Supports 4 position systems with highly accurate positioning.
GNSS Receiver Type
72-channel, GNSS L1C/A, SBAS L1C/A, QZSS L1C/A, QZSS L1-SAIF, GLONASS L1OF, BeiDou B1I , Galileo E1B/C
Position Accuracy
2.0 m CEP*
Sensitivity
Tracking/Navigation: 167 dBm | Cold starts: 148 dBm
Acquisition
Cold starts: 26s
Reacquisition: 2 s
Antenna
External FAKRA antenna (3m included) Code C
Accuracy
Velocity: 0.05m/s
Heading: 0.3 degrees
Others
IMU
6D IMU
Accelerometer
±2/±4/±8/±16 g full scale
Gyroscope
±125/±250/±500/±1000/±2000 dps full scale
PC Interfaces
Micro USB Type AB 2.0 interface (Standard version)
USB interface via the Molex Mini50 connector (Optional)
Data Storage Capability
Up to 32 GB eMMC storage (non-removable) (uses FIFO logic once the eMMC is full)
Supported Protocols
CAN Monitoring (RAW CAN signals, SAE J1939 support, FMS, CANopen, NMEA 2000, OBD2, CAN FD, UDS)
LEDs
4
Triggering
Trigger on CAN ID, CAN Signal, Digital Input.
Trigger on DM1 counter.
Filters
200* regular/extended ID filters per channel (range, acceptance)
File Format Supported
RXD, RXE, ASAM MDF (.mf4), CSV, MATLAB, ASC, BLF, TRC
Warranty
12 months from the date of invoice.
Support
Yes, during the warranty period
Origin
UK
Protocol
FTP/FTPS/HTTP/HTTPS
Data Transfer Protocol
FTPS and Amazon S3
Security Functions
Encryption of data logs, Locking of device.
Encryption Standard
RSA* (for locking device) and AES* (for log data)/GDPR/CCPA/SHA
Data Logger Configuration
Supplied with Influx ReXdesk configuration software, API, CLI
Software
Supplied with Influx ReXdesk configuration software, API, CLI
Free open Source ReXcloud platform for managing devices and data via your browser
Free open source asammdf software & API, DBC converting & plotting MF4 data
Free data convertors, CLI based/ .net DLL for converting RXD into RXE, ASAM MDF (.mf4), CSV, MATLAB, ASC, BLF, TRC
Free open-source AWS Lambda, Example Application for data processing/ Supports AWS time stream/DB to integrate with third party dashboard
Firmware
Supports free firmware updates for adding features
Analog Input
Number of channels
2 x Bipolar single-ended inputs
Range
± 10 V
Resolution (ADC)
12 Bit
Max sampling rate
1 kHz
Input Impedance
> 50 K Ohms
Safe Applied Voltage
±28 V
Digital Input
Number of channels
2 x Unipolar single-ended inputs
Input Switching Thresholds
Low < 0.8 V, High > 2.5 V (up to 28V)
Safe Applied Voltag
28 V
To set up a USB via the Molex connector, please specify this requirement when ordering, or the device must be sent back to Influx (as this requires some hardware modification).
*CEP - circular error probable
*FTPS- PROT P (Data channel encryption not supported.
Integrated GPRS
LTE modem
Category
Professional-grade uBlox Lara R2 Series LTE Cat1/ Quectel EC 20/25 CAT 4*
LTE CAT1 Bands
LTE FDD Bands: 1(2100 MHz) ,2(1500 MHz), 3(1800 MHz),4(1700 MHz), 7(2600 MHz), 8(900 MHz), 12(700 MHz), 13(700 MHz), 19(850 MHz), 20(800 MHz), 28(700 MHz)
Receiver input Sensitivity
-98dBm to -114dBm: 700MHz to 2100MHz
Coverage
Global * Available on request
Antenna
External FAKRA antenna (3m included) Code D
Server Interface
FTP/FTPS/S3
SIM Slot
External nano sim slot/ esim available on request
Over-The-Air (OTA)
Configuration & firmware over-the-air (COTA/FOTA). Configurable sync rate. Optionally disable
Heartbeat
Yes
Data Upload State
Yes
CAN Heartbeat
Optionally transmit heartbeat CAN frame with device info, device status, storage used RTC time & config-details
Snapshot
Decode and send CAN signals periodically to the server
HTTPS
Data & over-the-air updates can be sent via HTTPS (TLS 1.2) for secure transfer
User Policies
Fully customize access rights across devices and end users through S3 policies * (when using AWS upload)
Credential Encryption
S3 server credentials can be encrypted in the config on the device
* The region and category of the modem should be specified when ordering.
* Works with AT&T and T-Mobile in the USA.
BUS & Signals
Operating Voltage
Power supply - OBD
+5V to +27V
Power supply - USB
+4.5 to +5.5V
CAN/CAN FD
+2 to +3V
LIN
0 to +24V
Digital Input
0 to +28V
Analog input
± 10V
Transceiver Protection (CAN)
Bus fault protection: ±58 V
Thermal-shutdown protection (TSD)
Common mode input voltage: ± 12V
TXD dominant timeout (prevents network blocking in the event of a failure)
Under-voltage protection
Transceiver Protection (LIN)
±8 kV HBM ESD, ±2 kV CDM, ± bus Fault
TXD dominant timeout (to prevent the LIN node from permanently driving the LIN Bus dominant)
Power Voltage
5V for external sensor (current consumed should be less than 100mAmp)
Enclosure
PC+ ABS
IP Rating
IP 50
Dimension
L - 100 mm, W - 65 mm, H – 30 mm
Weight
112 Grams
Mounting Holes
4 mounting holes and screws
Stackable
Yes
Environmental Tolerance
Working temperature -40degC to +85degC; Humidity max 90%
Silent Mode
Listen only mode available (configurable Silent mode)
Power Saving
Wake Up On CAN, Wake up on Movement, Power Down Mode, Sleep Modes
Power Safe
100% power safe data logging - no file corruption when disconnected or in sleep mode
Power Consumption
Normal (usage without Cloud) <120mA at 12V
Normal (usage with Cloud) <300mA
Normal sleep <21mA
Deep sleep <10mA
Protection
Reverse voltage protection on CAN-bus supply