Rebel CT FAQs

What is different from other products

CT is more rugged with IP 65 rating and can support up to 7 CANbus and Flexray. One of the most powerful logger that supports advanced protocols like xCP/CCP.

Where can i get the Pinout details for this logger?
Does it support an SD Card & what is the maximum storage capacity of the logger?

SDHC up to 128GB

How to install drivers for this logger?

It is available under the influx technology folder in the Start menu. If it is not availble there, then please install from the Influx technology support page. https://www.influxtechnology.com/support

What is the current consumption of this logger?

250 to 400mA in operation, <2mA in power-down mode

Why my logger is not getting Detected?

Ensure the Rebel Driver is installed on your computer.

How can I move the Licence from one PC to another?

Open the Licence Manager from the Dialog Help section, Note down the Activation identification code, and De Activate the Licence from the existing PC. In the new PC, use the I Moved from Another PC option.

Why my logger is not recording CAN Data?

There could be several reasons:

  1. Ensure that you have configured the correct Baud Rate.

  2. Make sure the physical connections are correct.

  3. Ensure CAN Bus is terminated.

For more info, refer to our website's Troubleshooting flow chart in Dialog Help or the CAN Troubleshooting guide.

Why is the logger not recording OBD data?

There could be several reasons:

  1. Ensure that you are using the Proper Tester and Module Ident in ISO settings

  2. Ensure that the PID added is supported by the vehicle or not

  3. Disable Send start section and Sample only valid PID option in ISO settings

Why is the logger not recording GNSS data?

There could be several reasons:

  1. Ensure that the GNSS bus is added to the configuration

  2. Ensure that the GNSS antenna is interfaced with the logger

  3. Ensure that the vehicle is not inside any location where a satellite signal is not available

  4. If the CAN bus is logged along with GNSS, make sure that CAN Bus is active; if the CAN bus is not active, GNSS logging will stop after some time.

How can I get data from the logger SD card?

You can retrieve the data from the Rebel logger in two ways:

  1. Using the Dialog software via USB cable from the Rebel Explorer option

  2. Directly from the SD card by plugging it into the PC

My logger is recording data at the wrong time; what should I do?

Rebel Data loggers use Rechargeable batteries for the RTC; if the logger is not used for several weeks, the battery voltage will get low. You can plug the logger into a 12V power source and leave it for more than 12 hr to charge the cell. Once charged, you can set the time and confirm if the logger is keeping time. If the logger shows the wrong time, the battery might be dead and need to be replaced.

My logger is not connecting to StreamLog; what should I do to diagnose the issue?

There could be several reasons:

  1. Ensure that the SIM card is active and has sufficient data

  2. Ensure that the GPRS/LTE antenna is connected to the logger

  3. Check the Server and APN settings of the logger

  4. Ensure the logger serial number is added to the StreamLog administration tab.

  5. Test the connection with Streamlog Assistant. Refer Rebel Support page for the instruction manual.

My Dialog software is showing software licence expired, what should I do? Will the software stop working?

The standard SLA period for Dialog Software is one year (Key-based and Dongle-based Licence can be purchased with a longer SLA duration); once the SLA period is complete, the software will start showing the Licence Expiry notification. Once the Licence expires, you will no longer be eligible to get New software or firmware updates. The GNSS Map overlay feature in Dialog Plus Version will be disabled as it is subscription-based. All the other functions will not be affected.

I have connected the instrumentation device to Aux CAN1, but it is not powered ON. Why?

Ensure that the AUX Power settings are enabled in the configuration properties. Refer K-series Support page for more information.

How can I access the SD card of the Rebel CT logger?

A Flap protects the SD Card inside a Rebel CT logger. It can be opened by pressing the flap from the top and lifting it.

Which type of SD card will be purchased if my existing SD card is damaged?

Influx Technology recommends Sandisk Extreme Pro SD cards for its data loggers.

Where can I find the information about the LED if the LED functions written on my logger got erased?
  • F1. CAN 1 (MS) Bus traffic.

  • F2. Data Logger is configured and ready.

  • F3. Instrumentation/Trigger status.

  • F4. GPS status—flashes when acquiring data.

  • F5. CAN 0 (HS) Bus traffic.

    • Status. On—waiting, Flashing—Logging. Connect. They on—connected (USB/WIFI/LTE). SD Card. They are connected.

    • CN—Connect—ON—connected to StreamLog or DiaLog, Blinking—attempting to connect or active communication.

Why is the GPS Map function not working in my Dialog?

There could be several reasons:

  1. Ensure that you have an active internet connection

  2. If you are using the corporate connection, make sure the proxy is disabled

  3. Map overlay will be disabled if you don't have an active License

Last updated