Male 25-pin Standard D Type connector

(Mini 50 to D Sub 25 cable Sold separately).

Pin No

Pin Function

Pin 3

CAN Bus 3 Low Signal (Available only on 4x CAN Model)

Pin 4

Analog Input 1 - do not apply voltages outside of the -10 to +10V range

Pin 5

Wake-Up pin to wake logger from sleep mode (Appendix 1)

Pin 6

CAN Bus 1 Low Signal

Pin 7

CAN Bus 0 Low Signal

Pin 9

+5V to +27V Supply Voltage

Pin 10

+4.5V Instrumentation Supply Voltage, ensure that current draw is not more than 100mA

Pin 11

Erase PIN

Pin 12

Digital Input 0 - When used as an input, do not apply voltages outside the 0 to +12V range.

More information on the use of this pin can be found in Appendix 2

Pin 13

CAN Bus 2 Low Signal (Available only on 4x CAN Model)

Pin 15

LIN 0 Signal

Pin 16

CAN Bus 3 High Signal (Available only on 4x CAN Model)

Pin 17

Analog Input 0 - do not apply voltages outside of the -10 to +10V range

Pin 18

Analog Ground

Pin 19

CAN Bus 1 High Signal

Pin 20

CAN Bus 0 High Signal

Pin 21

Ground

Pin 22

Power Ground

Pin 23

Relay Out (Optional Feature)

Pin 24

Digital Input 1 - When used as input, do not apply voltages outside the 0 to +12V range

More information on the use of this pin can be found in Appendix 2

PIN 25

CAN Bus 2 High Signal (Available only on 4x CAN Model)

Notes:

  • The connector needs to be tightened properly to make a proper connection, ensuring reliable operation.

  • Each end of the CAN bus must be terminated with a 120 Ohm resistor across CAN H & CAN L.

  • Do not short-circuit any pins.

  • The maximum safe applied voltage for analogue and digital I/P is ±28 V.

Last updated