The OBD & INST Connector

The OBD & INST Connector is a Male 25-pin Standard D Type Connector with nuts.

Pin No

Pin Function

Pin 1

Analog Input 3- do not apply voltage outside of the -10 to +10 V range

Pin 2

LIN 1

Pin 3

CAN / CAN FD Bus 3 Low signal

Pin 4

Analog Input 1 - do not apply voltages outside of the -10 to +10V range

Pin 5

Wake-Up pin to wake logger from sleep mode (for use, see Appendix 1)

Pin 6

CAN Bus 1 (Medium Speed Bus) Low Signal

Pin 7

CAN Bus 0 (High-Speed Bus) Low Signal

Pin 8

NC

Pin 9

4.5-36V Supply Voltage

Pin 10

+4.5V Instrumentation Supply Voltage, ensure that the current drawn is not more than 100mA

Pin 11

Digital Input or Output 2 - Do not apply voltages outside of the 0 to +12V range when used as an input. When used as an Output, ensure that the current drawn is not more than 100mA.

More information on the use of this pin can be found in Appendix 2 and 3

Pin 12

Digital Input or Output 0 - Do not apply voltages outside the 0 to +12V range when used as an input. When used as an Output, ensure that the current drawn is not more than 100mA.

More information on the use of this pin can be found in Appendix 2 and 3

Pin 13

CAN /CAN FD Bus 2 (Instrumentation Bus) Low Signal

Pin 14

Analog Input 2 - - do not apply voltages outside of the -10 to +10V range

Pin 15

LIN 0

Pin 16

CAN / CAN FD Bus 3 High signal

Pin 17

Analog Input 0 - - do not apply voltages outside of the -10 to +10V range

Pin 18

Analog Ground

Pin 19

CAN Bus 1 (Medium Speed Bus) High Signal

Pin 20

CAN Bus 0 (High-Speed Bus) High Signal

Pin 21

Ground - e.g. to be connected to pin 5 of the OBDII Connector

Pin 22

Power Ground - e.g. to be connected to pin 4 of the OBDII Connector

Pin 23

Digital Input or Output 3 (can also be used as a switched power supply +Vd). Do not apply voltages outside of the 0 to +12V range when used as an input.

Pin 24

Digital Input or Output 1 - Do not apply voltages outside of the 0 to +12V range when used as an input. When used as an Output, ensure that the current drawn is not more than 100mA.

More information on the use of this pin can be found in Appendix 2 and 3

Pin 25

CAN / CAN FD Bus 2 (Instrumentation Bus) High Signal

WARNING

DON'T SHORT CIRCUIT OR OVERLOAD AND DIGITAL I/O, e.g. IF USING DIGITAL INPUT OUTPUT 3 TO SUPPLY POWER TO POWER A K-BOX OR A REBEL DASH, DO NOT CONNECT MORE THAT 1 K-BOX TO THIS OUTPUT AND BE CAREFUL THAT NO SHORT CIRCUIT OCCURS.

WARNING

OVERLOADING (I > 100mA) OF PIN 10 (+4.5V Instrumentation) WILL RESULT IN A DROP IN THE OUTPUT VOLTAGE.

WARNING

EACH END OF THE CAN BUS MUST BE TERMINATED WITH A 120 OHM RESISTOR ACROSS CAN H AND CAN L. THE LOGGER HAS DIP SWITCHES INSIDE THAT MAY BE TURNED ON IF IT IS AT THE END OF A CAN BUS TO ALLOW THE BUS TO BE TERMINATED EASILY.