The OBD & INST Connector

The OBD & INST Connector is a Male 25-pin Standard D Type Connector nut.

Pin No

Pin Function

Pin 1

Analog Input 3 - do not apply voltages outside of the -10 to +10V range

Pin 2

NC

Pin 3

NC

Pin 4

Analog Input 1 - do not apply voltages outside of the -10 to +10V range

Pin 5

Wake-Up pin to wake logger from sleep mode (for use, see Appendix 1)

Pin 6

CAN Bus 1 (Medium Speed Bus) Low Signal

Pin 7

CAN Bus 0 (High-Speed Bus) Low Signal

Pin 8

K-Line (1 wire bus) of ISO 9141

Pin 9

4.5-36V Supply Voltage

Pin 10

+4.5V Instrumentation Supply Voltage, ensure that the current drawn is not more than 100mA

Pin 11

Digital Input or Output 2 - Do not apply voltages outside of the 0 to +12V range when used as an input. When used as an Output, ensure that the current drawn is not more than 100mA.

More information on the use of this pin can be found in Appendix 2 and 3

Pin 12

Digital Input or Output 0 - Do not apply voltages outside the 0 to +12V range when used as an input. When used as an Output, ensure that the current draw is not more than 100mA.

More information on the use of this pin can be found in Appendix 2 and 3

Pin 13

NC

Pin 14

Analog Input 2 - do not apply voltages outside of the -10 to +10V range

Pin 15

NC

Pin 16

NC

Pin 17

Analog Input 0 - do not apply voltages outside of the -10 to +10V range

Pin 18

Analog Ground

Pin 19

CAN Bus 1 (Medium Speed Bus) High Signal

Pin 20

CAN Bus 0 (High-Speed Bus) High Signal

Pin 21

Ground

Pin 22

Power Ground

Pin 23

Digital Input or Output 3 (can also be used as a switched power supply +Vd). When used as an input, do not apply voltages outside of the 0 to +12V range

Pin 24

Digital Input or Output 1 - Do not apply voltages outside of the 0 to +12V range when used as an input. When used as an Output, ensure that the current drawn is not more than 100mA.

More information on the use of this pin can be found in Appendix 2 and 3

Pin 25

NC

WARNING

DON'T SHORT CIRCUIT OR OVERLOAD ANY DIGITAL I/O e.g. IF USING DIGITAL INPUT OR OUTPUT 3 TO SUPPLY TO POWER A K-BOX OR REBEL DASH, DO NOT CONNECT MORE THAN ONE K-BOX TO THIS OUTPUT AND BE CAREFUL THAT NO SHORT CIRCUIT OCCURS.

WARNING

OVERLOADING (I > 100mA) ON PIN 10 (+4.5V Instrumentation) WILL RESULT IN A DROP IN THE OUTPUT VOLTAGE.

WARNING

EACH END OF THE CAN BUS MUST BE TERMINATED WITH A 120 OHM RESISTOR ACROSS CAN H AND CAN L. THE LOGGER HAS DIP SWITCHES INSIDE, WHICH MAY BE TURNED OFF IF IT IS AT THE END OF A CAN BUS TO ALLOW THE BUS TO BE TERMINATED.

Last updated