INF4100: Rebel Start-Up Kit Harness
Last updated
Last updated
This cable is specifically designed to work with the Rebel 100, making it easier access the data loggerIO during the early engineering development stages.
The Rebel 100 is designed to be installed for long term event monitoring on production machinery and therefore the connector type is the same that you would normally find on an ECU. This type of connector is not very convenient for engineering development since these connectors are harder to work with. The Rebel100 start-up harness will enable you to connect to the Rebel 100 using standard9 PIN D-Sub connectors like the Rebel CT multi-connect cable.
Parameter | Value |
Cable Length | 890 mm |
Cable Thickness | UNKNOWN |
Connector A | Automotive Connectors ME ENCLOSURE CINCH 581-01-30-065 |
Connector B | 9-pin D-sub (DB9) plug/nuts, pins compatible with CiA 303-1 (CAN0 and Power) |
Connector C | 9-pin D-sub (DB9) socket, pins compatible with CiA 303-1 (CAN 1) |
Connector D | 9-pin D-sub (DB9) socket, pins compatible with CiA 303-1 (CAN 2) |
Connector E | 9-pin D-sub (DB9) socket, pins compatible with CiA 303-1 (CAN 3) |
Connector F | 15 pin D-Sub (DB15) socket, digital and analog inputs |
Temperature | Operating temperature: -20degC to +80degC (Start-up kit harness only) |
Weight | 469 g |
Colour | Black |