The ‘New Trigger’ panel allows users to select trigger action and trigger type for configuration.

  • Trigger Name– This enables the user to assign trigger names.

  • Trigger Action– This allows the user to choose the trigger action.

  • Logger Initial State– The initial state of the logger before a trigger is active.

  • Log Time (sec)– Enables the user to configure logging time for trigger action. For value =0, Continuous logging and for value >0.

    • After the First trigger event: the logger starts logging only for a specified time after the first trigger event.

    • After the Last trigger event: starts logging on the first trigger event and stops logging after the specified time after the last trigger event.

  • Pre-Trigger time– enables the user to configure the pre-logging time for trigger action.

  • Debounce– When the switch does not register, another click is relevant when you use Digital I/P.

  • Bus– This allows the user to choose the CAN bus.

  • Trigger by CAN/CAN FD Ident– The trigger will be active when the logger receives the message for the CAN ID.

  • Trigger by Parameter Value– The trigger will be active when the given parameter condition is satisfied.

  • Trigger by DM1 J1939 Counter Trigger will be active because DM1 counter increases/decreases/changes.

  • Trigger by Digital Channel– Trigger will be active for the condition that digital value increases/decreases/changes.

  • Use LED indication for the trigger–This allows the user to monitor the trigger status via LED(s).

    • Led Number: This allows the user to select a particular LED for a trigger.

    • Customize LED: This allows the user to customize the LED.

Last updated