Technical Specifications

Technical DataDescription

Power supply

4.5 to 31V DC (isolated)

Power consumption

K-TC8 / K-TC16 / K-TC32

Normal operation

120mA at 12V / 140mA at 12V / 200mA at 12V

Power down standby mode

24mA at 12V / 25mA at 12V / 30mA at 12V

Configuration

Via CAN bus with K-Cal for calibration. Via USB with TC Logger SW for logging configurations stored in the device

Interfaces (Isolated)

CAN bus (max 1000 kbps) and USB 2.0

Storage

8 GB eMMc

PC Interfaces

USB2.0 Type B (isolated)

Enclosure

Dimension (LxHxW): 115x56(K-TC8) / 79(K-TC16) / 149(K-TC32) x 105mm

Weight 450g(K-TC8), 570g(K-TC16), 900g(K-TC32)

IP 40

ABS/Aluminium Allow* (depending upon the stock availability)

Environmental

-40°C to +85°C

Humidity max 90%

Thermocouple Inputs

K, J, T-type

Accuracy ± 1°C

Measurement: -200 °C to 1250 °C

Connection type

Thermocouples: mini K, J ,T-Type (galvanically isolated)

Thermocouple Inputs

Number of channels

K-TC8: 8 channels, K-TC16: 16 channels, K-TC32: 32 channels (group of 8 thermocouples - each galvanically isolated)

Channel Input Types

K, J, T

Measurement Range

(-)200°C to (+)1200°C

Max Sampling Rate

20 Hz per channel

Max applied voltage

± 3.3 V

Peak Galvanic Isolation Voltage (from all other modules and power supplies)

Three-wire CAN Bus

780 V

Four-wire USB Bus

840 V

Two-wire power module

560V