Loading the K-TCxx configuration into DiaLog

Once the K-TCxx is configured as you wish to use it and have generated a DBC file that describes its configuration, you may load that description file into DiaLog and use it to configure the Logger to record the data output by the K-TCxx.

If you power it from the Logger, it will need to be powered from the vehicle or an external power source (NOT just via USB), and you will need to make sure the AUX power feature in the configuration is set to on. To do this, follow the Steps Below:

Open DiaLOG, Right-click on a project with CAN 0 HS bus, and select 'Properties.

Once the Edit Configuration window is displayed, click on the 'Settings' Tab and put a Checkmark in Aux Power On; Click OK.

Select the sleep mode suitable for you; it is recommended to use the following:

Wake On CAN 1 or Wake On CAN 0/CAN 1 or Power Down mode.

Create new BUS

Select the hardware type (CAN 1 MS) from the popup menu.

Enter the BUS properties.

Create New Protocol.

Select the CAN Monitor protocol.

Assign the settings and protocol name.

Notes:

  • Enable 'Log all channels' only if you wish to log all CAN messages appearing on the bus.

Select the import tab and click load DBC.

Or

Click the DBC tab on the right side.

Select the required signal from the DBC window.

Copy the selected signals and paste them into the DAQ list.

Send the configuration to the Logger.

Last updated