Pulse Duration Measurement
To measure Pulse duration, select Pulse duration in the drop-down box:
Also, set the CAN ID rate, where The K Box will transmit the result.
Set the Rate you wish to measure at:
Select the edge on which you wish to start measuring the pulse duration.
The Pulse Measured is shown below:
The Pulse MeasurRates are shown below:
The KBox will not send CAN messages (although the rate is met) until the required measurement is finished.
The KBox will re-calculate the message and Rate to prevent CAN bus overloading.
Examples:
Pulse frequency: 2000Hz (0.5ms). Rate: 50ms. CAN bus Speed: 125 kbps.
If there is no overloading of the CAN bus, a corresponding CAN Message will be sent every 50ms.
Pulse frequency: 2000Hz (0.5ms). Rate: 1ms. CAN bus Speed: 125 kbps.
If there is no overloading of the CAN bus, a corresponding CAN Message will be sent every 2ms.
Last updated