Connecting and powering the K-Box

The K-Box is powered via the CAN and power connectors. It has been designed with CiA® 102 pinout for the CAN bus and power to connect the device as easily as possible.

Most commonly, it will be powered from a Rebel Logger using the Multi Connect Cable, but you can also power it via pin 9 (4.5 to 36V) and pin-5 PowerGND of the nine-pin Sub D connectors. If connected via the multi-connect Cable, the CAN 1 (MS) bus is also connected, allowing the Logger to record the data transmitted from the K-Box.

Warning:

  • Several K-Boxes can be daisy chained via the additional DB9 Connector; however, they must have power supplied separately via power breakout in the Cable, not via the Logger. It can also be used to connect other devices, such as the Rebel Dash.

The pinout of the required Cable between the two K-Boxes is as follows:

Last updated