Connecting and powering the K-Box

The K-Box is powered via the CAN and power connectors. It has been designed with CiA® 102 pinout for the CAN bus and power to connect the device as easily as possible.

Most commonly, it will be powered from a Rebel Logger using the Multi-Connect Cable, but you can also power it via pin 9 (4.5 to 36V) and pin-5 PowerGND of the nine-pin Sub-D connectors. If connected via the Multi-connect cable, the CAN 1 (MS) bus is also connected, allowing the logger to record the data transmitted from the K-Box.

a) Setup for interfacing ReXgen Device with K-Box

Notes:

  • When using a ReXgen Air device with K-Box device, be sure to get in touch with the technical support team at Influx.

b) Setup for interfacing Rebel Device with K-Box.

The pinout of the required Cable between the two K-Boxes is as follows:

Last updated