LogoLogo
Home
  • 🏠Home
  • K-Series: Product Manual
    • K-Box: Product Manual
      • Connecting and powering the K-Box
        • Enable the AUX Power setting within the Logger Configuration
      • Configuring the K-Box
        • Installing the Kvaser Drivers
        • Installing ReXgen J2534 Drivers
        • Installing the Rebel Drivers
        • Installing the K-Cal Software
        • Using the K-Cal Software
          • Configuring the Analog Channels
          • Configuring the Digital Channels
            • The Input Function
            • Pulse Duration Measurement
            • Frequency Measurement
            • High-Frequency measurement
            • Cycle Duration Measurement
            • Duty Cycle/PWM Measurement
            • Event Measurement
            • RPM Measurement
            • The Output Function
          • Reprogramming the K-Box
          • Calibrating the K-Box
          • Erasing the Calibration
      • Using K-Box Cal to display data
        • Channel Display and Conversion
          • Selecting the Channel to display
          • Creating a Conversion Table
          • Applying a Conversion Table to a Channel
          • Applying a Formula to a Channel
        • Using the Oscilloscope to display data
          • Individually Adding items to the Oscilloscope.
          • Adding All Channels to the Oscilloscope (Method 1)
          • Adding All Channels to the Oscilloscope (Method 2)
          • Working with items added to the Oscilloscope
        • Using the Oscilloscope
        • Exporting a DBC file with conversion tables and Formulas
      • Making a Configuration in Dialog to Log K-Box
      • Appendix
        • Specifications
        • Pinout of the K Box
        • Pinout of the Multi Connect Cable
        • Measurement IEPE procedure
    • K-TC: User Quick Start Guide
      • Getting Started
        • Pinout details
        • Software Installation
        • Driver Installation
      • Software Introduction
        • Graphical Overview
        • Navigation Bar
        • Status Bar
        • Configuration Panel
        • Max Log Time (min)
        • Internal Storage Window
        • Show Data Log Window
      • The 'How to' Guide
        • Preparation of configuration
        • Setting up Max log time
        • Retrieving the Datalog
    • K-TC: Logger Manual
      • Introduction
        • Technical Specifications
        • Pinout of the K-TCxx
        • Software Installation
          • Installing the K-TCxx Cal Software
          • K-TCxx Driver installation
          • Installing the Rebel Drivers
      • Connecting and powering the K-TCxx
        • Enable the AUX Power setting within the Logger Configuration
      • Software Introduction
        • Interface Tab
          • General Tab
          • Measurement Tab
          • Thermo Couples Tab
          • Calibration
          • Reprogramming
          • Manufacturer
      • Using the K-TCxx Cal Software
        • Reprogramming the K-TCxx
        • Calibrating the K-TCxx
        • Erasing the Calibration
        • Configuring the K-TCxx
        • Using K-TCxx Cal to display data
        • Channel Display
        • Selecting the Channel to display
      • Using the Oscilloscope to display data
        • Individually Adding items to the Oscilloscope.
        • Adding All Channels to the Oscilloscope (Method 1)
        • Adding All Channels to the Oscilloscope (Method 2)
        • Working with items added to the Oscilloscope
        • Using the Oscilloscope
      • Exporting a DBC file
      • Loading the K-TCxx configuration into DiaLog
      • Appendix
    • K-TC 2.0: User Quick Start Guide (using K-Log)
      • Getting Started
        • Pinout details
        • Software Installation
        • Driver Installation
      • Software Introduction
        • Graphical Overview
        • Navigation Bar
        • Status Bar
        • Configuration Panel
        • Max Log Time (min)
        • Internal Storage Window
        • Show Data Log Window
      • The 'How to' - Guide
        • Preparation of configuration
        • Setting up Max log time
        • Retrieving the Datalog
    • K-TC 2.0 : Logger Manual (using K-CAL)
      • Introduction
        • Technical Specifications
        • Pinout of the K-TCxx
        • Software Installation
          • Installing the K-TCxx Cal Software
          • K-TCxx Driver installation
          • Installing ReXgen J2534 Drivers
          • Installing the Rebel Drivers
      • Connecting and powering the K-TCxx
        • Enable the AUX Power setting within the Logger Configuration
      • Software Introduction
        • Interface Tab
          • General Tab
          • Measurement Tab
          • Thermo Couples Tab
          • Calibration
          • Reprogramming
          • Manufacturer
      • Using the K-TCxx Cal Software
        • Reprogramming the K-TCxx
        • Calibrating the K-TCxx
        • Erasing the Calibration
        • Configuring the K-TCxx
        • Using K-TCxx Cal to display data
        • Channel Display
        • Selecting the Channel to display
      • Using the Oscilloscope to display data
        • Individually Adding items to the Oscilloscope.
        • Adding All Channels to the Oscilloscope (Method 1)
        • Adding All Channels to the Oscilloscope (Method 2)
        • Working with items added to the Oscilloscope
        • Using the Oscilloscope
      • Exporting a DBC file
      • Loading the K-TCxx configuration into DiaLog
      • Appendix
  • Pinouts for K-Series devices
    • K Box Pinouts (INF 2201)
    • KTC-XX Pinouts (INF 2204.02/5.02/6.02)
    • K AN8 Pinouts (INF 2210)
    • K IEPE Pinouts (Add-On) (INF 2213)
    • K PT Pinouts (Add-On) (INF 2212)
    • Appendix
      • The Wake Up Pin
      • Digital Input function
      • Digital Output function
Powered by GitBook
On this page
Export as PDF
  1. K-Series: Product Manual
  2. K-TC: Logger Manual
  3. Using the K-TCxx Cal Software

Calibrating the K-TCxx

PreviousReprogramming the K-TCxxNextErasing the Calibration

Last updated 1 year ago

You can calibrate the K-TCxx to Improve the Accuracy of the measurements. The software allows you to cycle through a number of measurement points. Once done, committing the calibration will apply the calibration to the K-TCxx, and measurement accuracy will be improved.

Pressing the Load Button Loads the calibration contained in the K-TCxx and displays them on the screen.

You may use this function if you wish to check that the K-TCxx is calibrated.

Alternatively, press the start button and attach the appropriate thermocouple test signals to the inputs of the K-TCxx in order to cycle through the test points in order to calibrate the K-TCxx for maximum accuracy:

Select the Channel of the Calibration Point you wish to calibrate by either clicking the Radio Button on the channel.

Or by clicking on the point you wish to calibrate in the field to the right

Adjust the input temperature from the calibrated test equipment that you are using to match the voltage for the test point:

If the input temperature is stable and correct, the calibration of the channel will be updated as follows:

If it is not, you will receive a warning:

Repeat the steps above until you have calibrated all the calibration points.

Once you have configured the K-TCxx as desired, click Commit to send the configuration to the K-TCxx. If you make a mistake and wish to clear the calibration, you can also use the Clear button.

This will save the calibration to the K-TCxx and create a report detailing the calibration:

Press the Start button: